PROVOR profiling float performance Gerard Loaec, Ifremer

PROVOR profiling float performance Gerard Loaec, Ifremer. Provor - main features. FSI (Excell) or SeaBird CTD (SBE41 CP) packages Self-ballasted, with active buoyancy control (hydraulic pump). More than 2000 cm3 of variable buoyancy, including surface emergence Max profiling depth : 2000 m

adli
Download Presentation

PROVOR profiling float performance Gerard Loaec, Ifremer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PROVOR profiling float performanceGerard Loaec, Ifremer History and performances of PROVOR float IAST6 Meeting – Brest - GL

  2. Provor - main features • FSI (Excell) or SeaBird CTD (SBE41 CP) packages • Self-ballasted, with active buoyancy control (hydraulic pump). More than 2000 cm3 of variable buoyancy, including surface emergence • Max profiling depth : 2000 m • Possibility of data acquisition on down-profile to parking depth and while drifting. CTD profile on the descent of the first cycle • Provor/ Apex format (variable / fixed number of samples) • ARGOS data transmission (28 bits ID) History and performances of PROVOR float IAST6 Meeting – Brest - GL

  3. Marvor/Provor history • Developed by Ifremer since 1990: • Woce: Marvor multi-cycle Rafos float • Argo/Coriolis : Provor profiling float • Through industrial partnership with Martec company and its subsidiaries: • Martec-Serpe-Iesm is responsible for sales in Europe • Martec-Metocean is responsible for sales in other countries History and performances of PROVOR float IAST6 Meeting – Brest - GL

  4. Martec Provor and Metocean Promet (between 2002 and 2004) • The same hydraulics, electronics, sensors, • the buoyancy is higher (bigger housing) • some differences in the software History and performances of PROVOR float IAST6 Meeting – Brest - GL

  5. Gyroscope Float Status Overview- December 2003 (by Y. Desaubies) 7 Provor and 7 Apex have been lost since IAST-5 History and performances of PROVOR float IAST6 Meeting – Brest - GL

  6. Technical improvements: stability at depth • Many Metocean floats deployed by Jamstec have shown ‘emergency ascent’; if the pressure is higher than the maximum allowed pressure, the floats pops up to the surface, without waiting for the end of the cycle. • The floats die between 70 and 90 cycles (Japanese National Report) with a parking depth of 2000 dbars. • Improvements: • The software has been updated on all floats to control the float at depth • It seems that the quality of the valve on the hydraulic engine is not stable and that low leakages inside the hydraulic circuit may happen. All floats have been fitted with a new valve (PSA) since the end of 2003. History and performances of PROVOR float IAST6 Meeting – Brest - GL

  7. Gyroscope WMO 6900162 – parking & profiling 1750 dbar Hydac valve History and performances of PROVOR float IAST6 Meeting – Brest - GL

  8. Gyroscope WMO 6900162 – parking & profiling 1750 dbar Hydac valve History and performances of PROVOR float IAST6 Meeting – Brest - GL

  9. Gyroscope WMO 6900162 – parking & profiling 1750 dbar Hydac valve A depth control means the float is outside its target depth History and performances of PROVOR float IAST6 Meeting – Brest - GL

  10. Provor WMO 1900081 parking depth=1500 dbars (PSA valve) profiling depth = 2000 dbars History and performances of PROVOR float IAST6 Meeting – Brest - GL

  11. Provor WMO 1900081 parking depth=1500 dbars (PSA valve) profiling depth = 2000 dbars History and performances of PROVOR float IAST6 Meeting – Brest - GL

  12. Provor WMO 1900081 parking depth=1500 dbars (PSA valve) profiling depth = 2000 dbars History and performances of PROVOR float IAST6 Meeting – Brest - GL

  13. Provor WMO 1900081 parking depth=1500 dbars(PSA valve) profiling depth = 2000 dbars A depth control means the float is outside its target depth History and performances of PROVOR float IAST6 Meeting – Brest - GL

  14. Technical improvements: grounding in surface cold water • Some Kordi and Pri floats don’t dive when the surface water temperature is low • Grounding detection: • When there is not water enough: • Either the floats stays on the sea floor waiting for the end of the cycle, • Or it moves away from the sea floor and drifts some meters higher • When the float is on the sea shore: • The mission is stopped and an Argos message is emitted every 100 seconds • By counting the number of valve actions and looking at the pressure; if the number of valve actions is higher than a given parameter and the pressure remains stable, grounding is detected History and performances of PROVOR float IAST6 Meeting – Brest - GL

  15. Technical improvements: grounding in surface cold water • On these floats: • The flow is low (low temperature) • The buoyancy when the float is deployed is high • Grounding is detected because the number of openings of the valve to reduce buoyancy is too high History and performances of PROVOR float IAST6 Meeting – Brest - GL

  16. Technical improvements: grounding in surface cold water • Improvements • by reducing the buoyancy when the float is deployed • by adjusting the grounding detection parameters 1°C 2°C 3°C Provor WMO 1900314 – 56° South History and performances of PROVOR float IAST6 Meeting – Brest - GL

  17. FSI sensors • Jumps in salinity • High stability P/T sensors WMO 1900207 . Eastern Tropical Atlantic . 30 cycles . 6 acceptables T/S profiles History and performances of PROVOR float IAST6 Meeting – Brest - GL

  18. FSI sensors • Possible reasons: • Breaking or rotation of the damping disk ? • Rotation of conductivity cell ? • Fouling ? • Corrections: • The damping disk is moved away from the sensors • Test of a new antifouling paint: unacceptable secondary effects • Remaining floats fitted with Fsi sensors are deployed in cold water • Most of Provor floats are now fitted with SBE sensors, but we are still working with FSI History and performances of PROVOR float IAST6 Meeting – Brest - GL

  19. Conclusions • The most important point is the stabilization at depth. The new valve should improve this. • Some differences between floats delivered by Metocean and Serpe-Iesm • From the beginning of 2004, There will be only one Provor design : • All floats are produced in France by Martec-Serpe-Iesm that is responsible for sales in Europe. • Martec-Metocean is responsible for sales in other countries and provides technical support and customization • All Provor floats will be tested using Ifremer facilities before they are shipped History and performances of PROVOR float IAST6 Meeting – Brest - GL

  20. A new CTD Profiling float • 19 Kgs • 100 cycles to 2000 m in all oceans • No ballasting • 800 cm3 variable buoyancy • SBE 41 CP sensors History and performances of PROVOR float IAST6 Meeting – Brest - GL