An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Stability Principles and Case Studies: Active Pharmaceutical Ingredient (API)andFinished Pharmaceutical Product (FPP) Gabriel K. Kaddu WHO Prequalification of Medicines Programme Assessment training, Copenhagen May 2014

  2. Overview • Purpose of stability • Section 2.3.S.7.1(a)/ 2.3.P.8.1(a): Stress Testing • Section 2.3.S.7.2/ 2.3.P.8.2: Post approval Stability commitments • Storage conditions • Section 2.3.S.7.3/ 2.3.P.8.3: Stability Data • Stability data • Other stability studies • Assessment Tips

  3. Purpose of stability • the purpose of stability testing is to: “provide evidence of how the quality of an API or FPP varies with time under the influence of a variety of environmental factors such as temperature, humidity and light.” • The stability programme also includes the study of product related factors that influence the quality of the API or FPP, for example, interaction of API with excipients, container-closure systems and packaging materials.

  4. API- 2.3.S.7.1 (a): Summary of stress testing • Stress testing: can help identify the likely degradation products which, in turn, can help to • establish the degradation pathways and the intrinsic stability of the molecule • and validate the stability-indicating power of the analytical procedures used. • Stress testing may be carried out on a single batch of the API

  5. API- 2.3.S.7.1 (a): Summary of stress testing • The objective of stress testing is not to completely degrade the API but to cause degradation to occur to a small extent, typically 10–30% loss of API • by assay when compared with non-degraded API. This target is chosen so that some degradation occurs, but not enough to generate secondary products. • For this reason the conditions and duration may need to be varied when the API is especially susceptible to a particular stress factor. • In the total absence of degradation products after 10 days the API is considered stable under the particular stress condition.

  6. API- 2.3.S.7.1 (a): Summary of stress testing

  7. FPP- Section 2.3.P.8.1(a): Stress testing • Formal stress testing for the FPP is not required, except: • Light stressing should be shown for the FPP (ICH Q1B) • If the API was not demonstrated to be light stable, and • If the packaging has not been demonstrated to be light protective • Stress testing is required as part of method validation, to show the assay and/or related compounds method is stability-indicating.

  8. Generic Guideline “The quality guideline (TRS 970 Annex 4, Section P.8.1) states, “If “protect from light” is stated in one of the officially recognized pharmacopoeias for the API or FPP, it is sufficient to state “protect from light” on labelling, in lieu of photostability studies when the container-closure system is shown to be light protective.”

  9. Light stress testing or photo-protective packaging We can look at:  “Protect from light” warnings in monographs  “Protect from light” in APIMF  Photo stress testing  Packaging

  10. FPP • photostability testing should be conducted on at least one primary batch of the FPP if appropriate. • If “protect from light” is stated in one of the officially recognized pharmacopoeias for the API or FPP it is sufficient to state “protect from light” on labelling, in lieu of photostability studies, when the container-closure system is shown to be light protective.

  11. Light stressing/Light transmission What is needed: Note that photostability testing according to ICH Q1B is “required”, however we use a pragmatic approach. • Either photostability demonstration (progression of API, FPP exposed, FPP in package) or • light transmission data. photostability testing should be conducted on at least one primary batch of the FPP if appropriate.

  12. Conclusion: Light stressing • Product should be shown to be light stable by photostability studies • showing the dosage form or dosage form in packaging is photostable. • By light transmission studies showing adequate protection of the packaging. • for blisters, which are not light protective, store blisters in carton (must be clear in QIS and on labels) • If product is not light stable; label should state that protect from light and container should be light protective – light transmission tests should be carried out on the container closure system

  13. Storage Conditions Climatic Zones • Zone I: 21ºC/45% RH • Zone II: 25ºC/60% RH (subtropical) • Zone III: 30ºC/35% RH(hot/ dry) • Zone IVA: 30ºC/65% RH (hot/ humid) • Zone IVB: 30ºC/75% RH (hot/very humid) Long term stability studies should cover all climatic zones if possible

  14. 3.2.S.7.1(b)/ 3.2.P.8.1(b): Accelerated and Long term testing • Stability data must demonstrate stability of the medicinal product throughout its intended shelf-life under the climatic conditions prevalent in the target countries. • Effective as of September 2011, the required long-term storage conditions for the WHO Prequalification of Medicines Programme are 30ºC ± 2º C/75% ± 5% RH. The use of alternative long-term conditions should be justified and should be supported with appropriate evidence.

  15. When the API or FPP stability studies were not conducted at PQ conditions: • The required long-term stability condition within the WHO Prequalification programme is 30ºC/75%RH for both API and FPP (Note: 30±2°C/ 65±5% RH is also acceptable for API), unless documented evidence can be provided that storage under these conditions is not possible due to the inherent chemical instability of the API.  In light of this, please provide long-term stability data for your API at 30C/75%RH or provide documented evidence that such storage conditions are inappropriate. 

  16. When the API or FPP stability studies were not conducted at PQ conditions: API • If long-term stability data at 30±2°C/ 65±5% RH or 30ºC/75%RH is not available for API, please commit to generating such data on the next three production scale batches of XXXXXXXX; provide a signed detailed protocol describing this stability programme; and commit to providing an amendment to alter the recommended storage conditions and retest period once 24 months stability data has been generated.

  17. FPP • In cases where the delay in accepting the dossier in order to obtain the stability data at 30ºC/75%RH is unacceptable: • The required long-term stability condition within the WHO Prequalification programme is 30ºC/75%RH, unless documented evidence can be provided that storage under these conditions is not possible due to the inherent instability of the product.  In light of this, please provide long-term stability data for your product at 30C/75%RH or provide documented evidence that such storage conditions are inappropriate. 

  18. FPP • If long-term stability data at 30ºC/75%RH is not available, you are required to commit to initiating studies at 30ºC/75%RH on the required number of primary batches; provide a signed detailed protocol describing the stability programme including a commitment for the date of initiation of studies, no more than 60 days from today’s date.

  19. Storage directions - temperature • Sometimes the applicant wants “store below 25°C” when they have demonstrated stability at 30°C. • Example comment to applicant: As of September 2011 we require stability data at 30C, and when this is demonstrated “store below 30C” is encouraged on labelling. Additionally, you should be aware that procurement agencies prefer products labeled, “store below 30C” as it indicates that stability was demonstrated at 30C. You are requested to reconsider the decision to label the product, “store below 25C”. We suggest and can explain, we cannot insist.

  20. 3.2.S.7.1(b)/ 3.2.P.8.1(b): Accelerated and Long term testing

  21. Exceptions: Reproductive Health and 2nd line TB drugs 1 • the requirement for stability at the time of submission only, may be reduced to; • no less than 3 months accelerated, • plus 3 months long-term data, for not less than two primary batches of at least pilot scale or in the case of an uncomplicated1 FPP (e.g. immediate-release solid FPPs (with noted exceptions), non-sterile solutions), not less than one batch of at least pilot scale and a second batch which may be smaller (e.g. for solid oral dosage forms, 25 000 or 50 000 tablets or capsules) of each proposed strength of the FPP.

  22. Exceptions: Reproductive Health and 2nd line TB drugs 2 • One of the primary batches (also called exhibit, pre-approval, registration, submission, or test batches) should be the batch that was used for bioequivalence studies. • All prequalification requirements for final acceptability of the dossier remain in effect, without exception; • the submission of updated stability data during the assessment period as it becomes available, and • a commitment to provide: • stability data on three production batches, and • process validation of three consecutive production batches, to be completed prior to marketing.

  23. 3.2.S.7.1(b)/ 3.2.P.8.1(b): Accelerated and Long term testing • Other storage conditions are outlined in the WHO stability guidelines: • for FPPs packaged in impermeable and semi-permeable containers and • those intended for storage in a refrigerator and in a freezer. • FPPs intended for storage below −20°C should be treated on a case-by-case basis. • Weight loss from plastic containers should be reported over the shelf-life (Liquids only).

  24. Stability of aqueous liquids Aqueous Liquids in semi-permeable containers – ICH Q1 and TRS953: long term studies should be at 25°C/40%RH or (for PQ) 30°C/35%RHplus 40°C/25%RH • Q1A: “Aqueous-based products packaged in semi-permeable containers should be evaluated for potential water loss in addition to physical, chemical, biological, and microbiological stability…Ultimately, it should be demonstrated that aqueous-based drug products stored in semi-permeable containers can withstand low relative humidity environments. ”

  25. Container closure systems 1 Semi-permeable (ICH and TRS 953): • Containers that allow the passage of solvent, usually water, while preventing solute loss […] • Examples of semi-permeable containers include plastic bags and semi-rigid, low-density polyethylene (LDPE) pouches for large volume parenterals (LVPs), and LDPE ampoules, bottles, and vials. • HDPE bottles are considered semi-permeable for storing liquids.

  26. Container closure systems 2 Impermeable • Containers that provide a permanent barrier to the passage of gases or solvents, e.g. sealed aluminium tubes for semisolids, sealed glass ampoules for solutions (ICH/TRS 953) and (TRS 953 only) aluminium/aluminium blisters for solid dosage forms. (Be careful of Al/Al, it depends on the sealing.)

  27. Container closure systems 3 • TRS 953: “Sensitivity to moisture or potential for solvent loss is not a concern for FPPs (for liquids) packaged in impermeable containers that provide a permanent barrier to passage of moisture or solvent. Thus stability studies for products stored in impermeable containers can be conducted under any controlled or ambient relative humidity condition. • Note: This does not apply to AL/ Al blisters. For Al-Al blisters, humidity in stability studies is just as important as for bottles.  It is just that moisture permeability does not have to be tested for the package.

  28. Section 3.2.S.7.2/ 3.2.P.8.2 Post-approval stability commitment • 2.3.P.8.2(a): Primary stability study commitment • 2.3.P.8.2(b): Commitment stability studies • 2.3.P.8.2(c): Ongoing stability studies

  29. Section 3.2.S.7.2/ 3.2.P.8.2:Post-approval stability protocol • number of batch(es) and different batch sizes, if applicable; • relevant physical, chemical, microbiological and biological test methods; • acceptance criteria; • reference to test methods; • description of the container-closure system(s); • testing frequency; • description of the conditions of storage

  30. Information on stability studies • – storage conditions; • – strength; • – batch number, including the API batch number(s) and • manufacturer(s); • – batch size; • – completed (and proposed) test intervals. • – container-closure system including orientation (e.g. erect, inverted, on-side) where applicable; important for liquids and semi-solids (e.g. erect, inverted, on-side): This is to study the possible interaction of the container closure system (the container and the closure) with the product.

  31. Section 3.2.S.7.3/ 3.2.P.8.3: Stability data • Results of the stability studies should be presented in an appropriate format : • tabular, • graphical, • Narrative • Summary of analytical methods • Information on the analytical procedures used to generate the data and validation of these procedures should be included.

  32. Stability reports • General information: name, manufacturing sites, date of manufacturing; batch number, batch size. • Container closure system, tests and acceptance criteria , test frequency, storage conditions—should in line with the protocol • Evaluation of stability data-- any significant change? Out of specification? out of trend? • Conclusions • retest period for drug substance, or shelf life, if applicable • storage condition

  33. API: Retest period • A retest period should be derived from the stability information and should be displayed on the container label. • After this retest period a batch of API destined for use in the manufacture of an FPP could be retested and then, if in compliance with the specification, could be used immediately (e.g. within 30 days). If retested and found compliant, the batch does not receive an additional period corresponding to the time established for the retest period. However, an API batch can be retested multiple times and a different portion of the batch used after each retest, as long as it continues to comply with the specification. For APIs known to be labile (e.g. certain antibiotics) it is more appropriate to establish a shelf-life than a retest period.

  34. Change in specifications A change in specifications is a stability issue.

  35. Stability issue – specifications have changed • Often during assessment specs are revised (by request usually) but there is no attention paid to whether stability data supports the change. • [This is another reason why it is so important to compare previous specs to the revised version provided.] • It is not sufficient to accept only a commitment for results for the new specification. • When we accept a shelf-life we are saying we are satisfied that the specifications will be met based on data we have assessed.

  36. Stability issue – specifications have changed If the revised limits can be assessed using current data, just ensure the new limits are met by most recent stability data. • Example tightened impurity limits: we can usually tell whether the new limits have been met by reviewing the available data Imp A: up to 0.2% reported; meets new limit of NMT 0.1% Exception in this case is TLC: semi-quantitative results were provided: Imp A: < 0.2% reported; can’t tell if new limit (0.1%) is met

  37. Stability issue – specifications have changed The revised limits may require new testing/reporting, such as inclusion of a limit for a new impurity or a different dissolution timepoint. In these cases, the available data is insufficient: 1. If studies are completed: Request available data on retained samples if not far beyond expiry, or available new studies 2. If studies are ongoing: Request that data at subsequent stations include the revised limits.

  38. Stability-indicating parameters • Stability-indicating parameters must be understood for the API and FPP. • API: any parameter susceptible to change (appearance, assay, impurities*, others specific to the API e.g. polymorphism if necessary) • Why all specified impurities, and not just degradation products for the API? The way to determine if an impurity is also a degradant is to do the stability and monitor known impurities.  A process impurity could also turn out to be a degradant. The degradants for an API by one manufacturing process may differ from that of another, for example due to the presence of trace metals or other reagents.

  39. Stability-indicating parameters FPP: Physical (description, moisture, quality parameters (DT, dissolution)); • Moisture is particularly important for solid orals in blisters and strips, and moisture-sensitive products in bottles. Chemical (assay, degradants, preservatives); Efficacy of additives Container/closure interactions, when applicable (e.g. liquid in plastic);

  40. Evaluation and Extrapolation of results • if significant change was not observed within 6 months at accelerated condition and the data show little or no variability, the proposed shelf-life could be up to twice the period covered by the long-term data, but should not exceed the long-term data by more than 12 months • The proposed storage statement and shelf-life (and in-use storage conditions and in-use period, if applicable) for the FPP should be provided. The recommended labelling statements for use based on the stability studies, are provided in the WHO stability guidelines

  41. Provisional shelf-lives 1 • Ideally, these would not exist. As long as there are significant question(s) and the data did not cover the proposed shelf-life, updated data should be requested/provided. • Example problem: 12 mo data provided in blisters and then the study was discontinued. A provisional 24 mo shelf-life was accepted. Is this okay? • No. You can’t extrapolate based on data for batches when the study on these batches will not be continued over the extrapolated period.

  42. Provisional shelf-lives 2 Never accept extrapolation for cancelled studies. ICH Q1E: “a retest period or shelf life granted on the basis of extrapolation should always be verified by additional long-term stability data as soon as these data become available.” WHY? 1) we don’t know why the studies were cancelled. 2) we don’t have the normal assurance of the “primary stability commitment”, and 3) if they cancelled studies (in the above case they claim because of low market potential), the odds of them starting a new study are slim. This is very risky and against all practices.

  43. Updated stability data and extrapolation – what NOT to say “Please provide update stability data. In order to support of 24 months shelf life of the product, long term stability data up to at least 12 months should be provided, with commitment to continue long term testing for a period of time sufficient to cover the whole proposed shelf life.” The above suggests that we will accept 12 months data, and extrapolate on this, even if longer data is available. What TO say: “In order to support the proposed shelf-life, you are requested to provide available updated stability data.”

  44. Extrapolation • Ask for the available updated stability data each time comments are going out. • Don’t imply that extrapolation is a guarantee as in the example question. It depends on the actual data provided. • Don’t offer extrapolation unless it has specifically been proposed by the applicant.

  45. 2.3.S.7.1(b)/ 2.3.P.8.1(b): Summary of accelerated and long term testing • Summary of stability results observed

  46. Other stability studies Hold time studies: validate holding times - how long an intermediate can be stored, including bulk product prior to final packaging In-use studies: studies to show that normal in-use of the product will not result in significant changes in the product Transport studies: studies to show a bulk product will still meet the release limits after transportation to the packaging site Each of these studies have their own requirements.

  47. Hold time Studies 1 Summary of acceptable hold times A maximum processing time of one month (30 days) is acceptable without validation. (industry standard) Any hold time for an intermediate or the bulk product >30 days must be supported by stability studies. In addition, cumulative hold times should not exceed 90 days, or additional supporting data is required.

  48. Hold time studies 2 These are a type of stability study to determine hold times for example for blend, cores and final coated tablets in bulk. Necessary when hold time > 30 days or there are multiple hold times (e.g. 30+30+30+30). • All stability-indicating parameters should be included in the studies. • The applied limits are important. Release limits should be applied to final tablets, not just shelf-life.

  49. Hold time studies 3 Beware of even short hold times for liquid intermediates. Example comment: • The API-loaded suspension is allowed to be stored for three days before being further used for processing. The suspension contains HPMC and lactose, both of which could promote microbial growth. Please provide the supporting data for microbial stability of the suspension and the chemical stability of the API for the proposed waiting period of three days during processing.

  50. Hold time studies 4 Common issue: a number of intermediates have hold times Beware of cumulative hold times, even if separately validated The date of production of a batch is defined as the date that the first step is performed involving combining the API with other excipients. • Even if appropriate hold studies have been provided to support hold times, the hold times still may be unacceptable.