KDAC QUALITY CONTROL. C-100 HVAC MODULE EVA SENSOR Malfunction. Feb .21. 2011. C-100 EVA SENSOR Malfunction. Frozen at A/C tube . 1. Problem definition . #1. #2. Vehicle: Winstorm Part name: EVA Sensor Description : Icing occurrence Occurrence&Date: WARRANTY (CKD @GM-UAE)
E N D
KDAC QUALITY CONTROL C-100 HVAC MODULE EVA SENSOR Malfunction Feb .21. 2011
C-100 EVA SENSOR Malfunction Frozen at A/C tube 1. Problem definition #1 #2 • Vehicle: Winstorm • Part name: EVA Sensor • Description : Icing occurrence • Occurrence&Date: WARRANTY (CKD @GM-UAE) • Quantities: 2pcs(2/9, received) ▣ Vehicle information
C-100 EVA SENSOR Malfunction 2. Returned part analysis ▣ Basic performance test (Resistance value check @0℃,25℃,50℃)
C-100 EVA SENSOR Malfunction 2. Returned part analysis ▣ X-Ray Analysis(#1) ② ① ① Thermistor chip: OK ② Wire soldering: OK Terminal & Wire : OK ▣ X-Ray Analysis (#2) ② ① ① Thermistor Chip: OK ② Wire soldering: OK Terminal & Wire : OK 3. Conclusion • No Trouble Found (Resistance value OK , X-Ray OK)