1 / 15

Result of T-violating Muon Polarization Measurement in the K + → p 0 m + n Decay

Result of T-violating Muon Polarization Measurement in the K + → p 0 m + n Decay. C. Rangacharyulu Saskatoon, SK for the KEK-E246 collaboration June 7, ‘04 DAPHNE-04. Transverse muon polarization E246 experiment Analysis Result of the total data. E246 collaboration.

Download Presentation

Result of T-violating Muon Polarization Measurement in the K + → p 0 m + n Decay

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Result of T-violating Muon Polarization Measurement in the K+→p0m+n Decay C. Rangacharyulu Saskatoon, SK for the KEK-E246 collaboration June 7, ‘04 DAPHNE-04 • Transverse muon polarization • E246 experiment • Analysis • Result of the total data

  2. E246 collaboration Japan● KEK ● Univ. of Tsukuba, ●Tokyo Institute of Technology ●Univ. of Tokyo ● Osaka Univ. Russia ●Institute for Nuclear Research Canada●TRIUMF ●Univ. of British Columbia ● Univ. of Saskatchewan ● Univ. of Montreal Korea● Yonsei Univ. ● Korea Univ. U.S.A.● Virginia Polytech Institute ● Princeton Univ. Taiwan ● National Taiwan Univ.

  3. Transverse Muon Polarization inK+→p0m+n Km3decay form factors and T violation History ofKm3 transverse polarization experiments • KL→p−m+n Bevatron 1967 Imx = -0.02 ±0.08 • KL→p−m+n Argonne 1973 Imx = -0.085 ±0.064 • KL→p−m+n BNL-AGS 1980 Imx = 0.009 ±0.030 • K+→p0m+n BNL-AGS 1983 Imx = -0.016 ±0.025

  4. KEK E246 experiment Features • Stopped K+ experiment with a SC toroidal spectrometer • Measurement of all decay kinematics directions • Double ratio measurement with small systematic errors History • 1992-1995 : detector construction • 1996-2000 : data taking • 1999 : first result published with 1/4 of data Imx= -0.023 ± 0.007(stat) ± 0.003(syst) [M.Abe et al., Phys.Rev.Lett. 83(1999) 4253] • 2001-2003 : analysis • 2004 (this conference) : report of the final result Byproducts • K+→m+ng :PT = -0.0064 ± 0.0185(stat) ± 0.0010(syst) [V.Anisimovsky et al., Phys.Lett. B562 (2003) 166] • Ke3, Kp2g, Ke4, ...

  5. E246 experimental setup [J.Macdonald et al.; NIM A506 (2003) 60] End view Side view K+→p0m+n

  6. Muon polarimeter One-sector view Cross section y(cm)

  7. CsI(Tl) and kinematics CsI barrel fwd and bwdp0 /g PT directions fwd -p0 (g ) bwd -p0 (g ) Double ratio measurement

  8. Experimental data K+m3 event selection e+time spectra e+ time spectrum CsI(Tl) analysis : 2g Momentum analysis TOF analysis

  9. Two independent analyses • Two analyses by two teams with • their own analysis policy and • event selection methods Comparison of good Km3 event e.g. :1998 2g events1g events A2 1221 k 1264 k A1 918 k 909 k • Combination of the two analyses by resorting of events to 6 data sets 2g —— A1•A2A1•A2 A1•A2 1g —— A1•A2A1•A2A1•A2 Merits of two analysis method • Cross check of data quality by A0, decay plane rotation qrand qzandPT • Comparison of sensitivity by normal asymmetry ANand <cosqT> • Check of data quality in e.g. A1 by comparing A1•A2 and A1•A2-bar • Estimate of systematic error by comparing <cosqT> ofA1•A 2 fromA1 and A2 • Improvement of statistical error

  10. Data quality check Null asymmetry check Sensitivity check AN=(Aleft - Aright)/2 Aleft = [(Ncw/Nccw)left -1]/2 Aright= [(Ncw/Nccw )right -1]/2 A0=[(Ncw/Nccw)total -1]/2 total = fwd + bwd • 6 data sets for each period • Open circles are 2g events and dots are 1g events. • Null asymmetry is canceled by double ratio (fwd-bwd).

  11. Result PT = - 0.0017 ± 0.0023(stat) ± 0.0011(syst) ( |PT | < 0.0050 : 90% C.L. ) Imx = - 0.0053± 0.0071(stat) ± 0.0036(syst) ( |Imx | <0.016 : 90% C.L. )

  12. Systematics check Consistency among data Sector dependence ● = 2g ; o =1g; ●=1996-1997; o=1998; ★=1999-2000 Decay plane rotation Imx = -0.0053±0.0071 (c2/d.o.f = 0.78) |qr(fwd)- qr(bwd) | ≤ 4.6×10-4 rad |qz(fwd)- qz(bwd) | ≤ 2.6×10-4 rad

  13. Source of Error S12 fwd/bwddPTx 104 e+ counter r-rotation x o 0.5 e+ counter z-rotation x o 0.2 e+ counter f-offset x o 2.8 e+ counter r-offset o o <0.1 e+ counter z-offset o o <0.1 m+ counter f-offset x o <0.1 MWPC f-offset (C4) x o 2.0 CsI misalignment o o 1.6 B offset (e) x o 3.0 B rotation (dx) x o 0.4 B rotation (dz) x x 5.3 K+ stopping distribution o o <3.0 m+ multiple scattering x x 7.1 Decay plane rotation (qr) x o 1.2 Decay plane rotation (qz) x x 0.7 Kp2 DIF background x o 0.6 K+ DIF background o x < 1.9 Analysis - - 4.0 Total <11.4 Systematic errors • S12 : 12-fold rotationalcancellation • fwd/bwd : p0 forward/backward cancellation

  14. Model implications Three Higgs doublet model L= (2√(2)GF)1/2 S[aiULKMDDR + biURMUKDL+giNLMEER] Hi+ + h.c. Imx = Im(a1b1*) ×(v2 /v3)2× (mK/ mH+)2 = Im(a1g1*) × (mK / mH+)2 vi : vacuum expectation values ai, bi, gi : mixing matrix elements • |Imx | < 0.016 (90% C.L.) ⇒ Im(a1g1*) < 544 (at mH=mZ) • cf. BR (B→Xtnt) ⇒ Im(a1g1*) < 1900 (at mH=mZ) − Neutron EDM in 3HD model dn≈ 4/3dd∝Im(a1b1*) ×md/ mH2 v2/v3 = mt/mt[R.Garisto and G.Kane, Phys. Rev. D44 (1991)2789 ] • |Imx | < 0.016 (90% C.L.) ⇒ dn< 9 ×10-27 e cm • cf. dnexp < 6.3×10-26e cm

  15. Summary • Transverse muon polarization inK+→p0m+n decay is a good probe of • CP violation beyond the standard model. • The final result of the KEK-E246 experiment showed no evidence for • T violation with Imx = - 0.0053± 0.0071(stat) ± 0.0036(syst) , or • |Imx | <0.016 (90% C.L. ). • This limit constrains the parameters of some non-standard CP violation • models with high sensitivity. • We are going to propose a next generation PT experiment at the high • intensity accelerator J-PARC.

More Related