An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IENG 486 - Lecture 19 Introduction to Mil Std 105E IENG 486 Statistical Quality & Process Control

  2. Assignment • Reading: • Chapter 15 • Sections 15.1 – 15.2.4: pp. 632 - 646 • Sections 15.4 – 15.4.3: pp. 655 – 663 • Homework: • Download and complete Last Assign: Acceptance Sampling • Requires MS Word for Nomograph • Requires MS Excel for AOQ pp. IENG 486 Statistical Quality & Process Control

  3. Military Standard 105E(MIL STD 105E)(ANSI/ASQC Z1.4, ISO 2859) • Most widely used acceptance sampling system for attributes • MIL STD 105E is Acceptance Sampling System • collection of sampling schemes • Can be used with single, double or multiple sampling plans • We will consider single sampling plans for this course IENG 486 Statistical Quality & Process Control

  4. Inspection Types • Normal Inspection • Used at start of inspection activity • Tightened Inspection • Instituted when vendor’s recent quality history has deteriorated • Acceptance requirements for lots are more stringent • Reduced Inspection • Instituted when vendor’s recent quality history has been exceptionally good • Sample size is usually smaller than under normal inspection IENG 486 Statistical Quality & Process Control

  5. Switching Rules IENG 486 Statistical Quality & Process Control

  6. Procedure for MIL STD 105E • STEP 1: Choose AQL • MIL STD 105E designed around Acceptable Quality Level, AQL • Recall that the Acceptable Quality Level, AQL, is producer's largest acceptable fraction defective in process • Typical AQL range: • 0.01%  AQL  10% • Specified by contract or authority responsible for sampling IENG 486 Statistical Quality & Process Control

  7. Procedure for MIL STD 105E • STEP 2: Choose inspection level • Level II • Designated as normal • Level I • Requires about one-half the amount of inspection as Level II • Use when less discrimination needed • Level III • Requires about twice as much inspection as Level II • Use when more discrimination needed • S-1, S-2, S-3, S-4 • Four special inspection levels used if very small samples necessary IENG 486 Statistical Quality & Process Control

  8. Procedure for MIL STD 105E • STEP 3–Determine lot size, N • Lot size most likely dictated by vendor • STEP 4: Find sample size code letter • From Table 15-4, p 657 • Given lot size, N, and Inspection Level, use table to determine sample size code letters • STEP 5: Determine appropriate type sampling plan • Decide if Single, Double or Multiple sampling plan is to be used IENG 486 Statistical Quality & Process Control

  9. Procedure for MIL STD 105E • STEP 6: Find Sample Size, n, and Acceptance Level, c • Given sample size letter code, use Master Tables: 15-5, 15-6, and 15-7 on pp.658-660 • Find n and c for all three inspection types: • Normal Inspection • Tightened Inspection • Reduced Inspection IENG 486 Statistical Quality & Process Control

  10. Example • Suppose product comes from vendor in lots of size 2000 units. The acceptable quality level is 0.65%. Determine the MIL STD 105E acceptance-sampling system. IENG 486 Statistical Quality & Process Control

  11. Normal Insp. Level Lot Size = 2000 IENG 486 Statistical Quality & Process Control

  12. AQL Plan K Sample 125 units. Ac = 2, accept if defects ≤ 2. Re = 3, reject entire lot if defects ≥ 3. IENG 486 Statistical Quality & Process Control

  13. AQL Plan K Sample 125 units Ac = 1, accept if defects ≤ 1. Re = 2, reject entire lot if defects ≥ 2. IENG 486 Statistical Quality & Process Control

  14. AQL Plan K Sample 50 units Ac = 1, accept if defects ≤ 1. Re = 3, reject entire lot if defects ≥ 3. IENG 486 Statistical Quality & Process Control

  15. Questions & Issues IENG 486 Statistical Quality & Process Control