240 likes | 406 Views
EOLO Extra kW HP Wall hung boiler with condensing heat exchanger , for high temperature systems. Main features. New models Functioning Efficiency Dimensions and connections Control panel Applications Outdoor installation Main Option kits Availability and list price. New Models.
E N D
EOLO Extra kW HPWall hung boiler with condensing heat exchanger, for high temperature systems
Main features • New models • Functioning • Efficiency • Dimensions and connections • Control panel • Applications • Outdoor installation • Main Option kits • Availability and list price
New Models Immergas expands its range of condensing boilers with the new EOLO Extra kW HP range. The new boilers are characterized by the presence of a traditional heat exchanger (copper made) combined to a special condensing heat exchanger.
Applications New versions EOLO Extra kW HP represent the Entry Level in the Immergas condensing range. This solution takes the advantages of the condensation technology and it represents the best choice for residential new buildings (where price assumes detail relief) or in case of traditional boiler substitutions.
Features • Two models with heat outputs of 24 e 30 kW • Instantaneous production of D.H.W • Designed for traditional systems, working with high temperatures only (for example radiators). • Outdoor and indoor installation (IPX5D)
Features • Special condensing heat exchanger, located downstream main heat exchanger • Remarkable structural simplicity, thanks to a conventional boilerlike frame • High efficiencies • Compact dimensions (25 cm depth)
Functioning The structure is completely similar to a traditional boiler with copper heat exchanger, to which a special Aluminium condensing exchanger has been added in series. Heat Recover
Functioning The heat recover absorbs a further part of the heat contained in the fumes, allowing to preheat the water before the primary heat exchanger. Heat Recover Primary Heat Exchanger Condensate drain pipe
Efficiency • Efficiency targets are analogous to ones of Condensing Boilers • Efficiency at nominal heat output (80/60 °C): • EOLO Extra 24 kW HP = 97,3 % • EOLO Extra 30 kW HP = 96,4 %
Dimensions and connections • only 25 cm depth • standard provided with anti-freeze -5 ºC (-15 °C with option kit)
Control panel 1 - Stand-by 2 - Burner ON 3 - D.H.W. ON 4 – Central heating ON 5 - Temperature / Ignition lock 6 - Temperature / Flue pressure switch safety 7 - Temperature / Low system pressure 8 - Temperature / Insufficient circulation 9 - Temperature / Delivery NTC probe faulty 10 - Temperature / D.h.w. NTC probe faulty 11 - Temperature / Overheating lock 12 - Main switch (stand by, d.h.w., c.h. and reset) 13 - D.H.W. Temperature knob 14 - Central heating temperature knob 15 - Manometer
Schema idraulico 1 - D.h.w. flow switch 2 - Limitatore di flusso 3 - System filling valve 4 - D.h.w. probe 5 - 3 bar safety valve 6 - Gas valve 7 - Burner 8 – Sealed room 9 – Primary heat exchanger 10 – Draught diverter 11 - Fan 12 – Flue pressure switch 13 – Flue thermostat 14 - Secondary heat exchanger 15 – Delivery probe 16 – Safety thermostat 17 – Expansion vessel 18 – Air vent 19 - Circulator 20 – System pressure switch 21 – D.h.w. plated heat exchanger 22 – Motorzed 3 way valve 23 – Automatic bypass 24 – Draining valve 25 – Condensing drain
Diagram of the pump– 24 version Head (mH2O) Head (kPa) Flow rate (l/h) A = Available head with zone’s circulator speed set at maximum by pass excluded B = Available head with zone’s circulator speed set at maximumcon by pass included C = Available head with zone’s circulator speed set to 2 con by pass excluded D = Available head with zone’s circulator speed set to 2 con by pass included
Diagram of the pump– 30 version Head (mH2O) Head (kPa) Flow rate (l/h) A = Available head with zone’s circulator speed set at maximum by pass excluded B = Available head with zone’s circulator speed set at maximumcon by pass included C = Available head with zone’s circulator speed set to 2 con by pass excluded D = Available head with zone’s circulator speed set to 2 con by pass included
Applications The main difference with the condensing models is that EOLO EXTRA kW HP are designed for traditional systems, working with high temperatures only (for example radiators).
Applications The EOLO Extra kW HP models can’t be combined directly to underfloor panels (low temperature systems).
Condensing drain • Simple condensate disposal, thanks to built siphon, similarly to other condensing models
Outdoor installation The boiler can be installed outside, in partially protected places (for example under a balcony); the protection index is IPX5D.
Climatic thermoregulation (optionals) Amico Remote Control (CAR) External Sensor • Central heating temperature modulation according to the external and internal temperatures means lower consumption
Super CAR Remote Control (optional) • Climatic programmer and modulating room thermostat • Easy to use thanks to a wide display and only one setting knob
Option kits • Connection kit cod. 3.019329 • Anti-freeze protection kit a -15 °C cod. 3.017324 • Cover kit cod. 3.016022 • Additional 2 litres expansion vessel cod. 3.016224 • Telephonic Remote Control cod. 3.013305 • DIM range
Flue pipes green range EOLO Extra kW HP can be matched to the same flue pipes for the other Immergas condensing models; the main kit options are: • Twin pipe kit Ø 80/80 cod. 3.012002 • Concentric horizontal kit Ø 60/100 cod. 3.012000 • Concentric vertical kit Ø 60/100 cod. 3.016833