1 / 13

Tel Aviv University : E. Etzion , Y . Benhammou , N. Hod, O . Ben-Ami, Y. Silver

TGC L1 Trigger On-Line Monitoring. Tel Aviv University : E. Etzion , Y . Benhammou , N. Hod, O . Ben-Ami, Y. Silver Weizmann Institute : L . Levinson D. Lellouch, O. Silbert. Status, May 2009. Unified with TGC DAQ software and configurations.

ally
Download Presentation

Tel Aviv University : E. Etzion , Y . Benhammou , N. Hod, O . Ben-Ami, Y. Silver

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TGC L1 Trigger On-LineMonitoring Tel Aviv University: E. Etzion, Y. Benhammou, N. Hod, O. Ben-Ami, Y. Silver Weizmann Institute: L. Levinson D. Lellouch, O. Silbert

  2. Status, May 2009 • Unified with TGC DAQ software and configurations. • Working modules are: -- 4 GNAM segments (OverView, HitProfile, pTthreshold, TriggerProfile).-- 3 DQMF segments (GlobalChamber, Timing, SubsectorOccupancies). • DQMF algorithms are not yet fine-tuned. • DQA↔DB interaction is in preparation, see next slides. • Histograms: ~2000 for SHIFT, ~200 for EXPERT, see next slides.These numbers are not static. • Documentation for the shifter / expert is in preparation.

  3. Code and xml(s) are installed and checked under tdaq-02-00-01 in:-- /det/muon/standalone/sw/tdaq-02-00-01/detectors/muons/installed/-- /det/muon/standalone/databases/tdaq-02-00-01/muons/segments/TGC/ (GNAM/,DQMF/,OHP/)All tested in TGC-Standalone and ready to be copied in the combined area together with all TGC DAQ software and xml(s). • Another GNAM segment for TGC-Efficiency is in preparation. • Using Jumbo-packets (for large events) – not yet fully tested.will be ready before the coming cosmic run. • New “13 sectors” structure require many modifications in decode and in QDA tests. In process… • Several new dqm algorithms for DQMF segments.Some are relative algo’s - where we don’t have good references yet. • New tombox (soon…)

  4. DQA ↔ DB interactions Java Viewer IS TGC DB GNAM Histo’s DQMF COOL DQMD • Data from DQMF will not go directly to the TGC ORACLE DB / COOL. • Instead, it will be stored in IS (as arrays, in a global numbering scheme). • Then it will be pooled from there by a special (TGC-DAQ) tool to be translated (to the chamber level) and registered in the ORACLE DB. • From the ORACLE DB it will be sent to COOL along with other TGC info. • The information to register to the IS, and then to the DB is (for now):-- chamber status (“on” / “off”),-- number of dead / hot channels in the chamber (#dead, #hot),-- chamber timing performance (#prevBC, #centBC, #nextBC).

  5. Histograms (HitProfile, ohpNexus)

  6. Histograms (HitProfile, ohpNexus)

  7. Histograms (HitProfile, DQMD)

  8. Histograms (GlobalChamber, DQMD)

  9. Histograms (GlobalChamber, DQMD)

  10. Histograms (Timing, DQMD)

  11. Histograms (HitProfile, ohpNexus & DQMD)

  12. Histograms (HitProfile, ohpNexus & DQMD)

  13. Histograms (some EXPERT histos, ohpNexus)

More Related