1 / 35

Medical Physics

Medical Physics. Contents. Physics of the Eye and Ear Biological Measurement and Imaging. The Eye. Ciliary muscles relax (lens flattens)  distant objects Ciliary muscles contract (lens gets fat)  close up objects Refraction at cornea produces inverted image on retina. The Eye.

Download Presentation

Medical Physics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Medical Physics

  2. Contents • Physics of the Eye and Ear • Biological Measurement and Imaging

  3. The Eye • Ciliary muscles relax (lens flattens)  distant objects • Ciliary muscles contract (lens gets fat)  close up objects • Refraction at cornea produces inverted image on retina

  4. The Eye • Dim light: iris dilates to allow light in - rods operative (see in black & white) • Bright light: iris contract to avoid light flooding - cones are sensitive to either red, green & blue light • Colour seen depends on proportion in which each type of cone is stimulated

  5. The Eye • Nerve ends respond to changes in light intensity • Eye is constantly scanning so that new nerves are stimulated • Persistence of vision: limited response of eye due to delay times in between nerve ending responses • If the eye is focused on a near object in bright light, distant objects are visible reasonably clearly. If the eye focuses on the same object at the same distance in dim light, distant objects are blurred. The depth of field is reduced

  6. Defects of Vision & Their Correction • Convex Lens: light rays converge Power (Dioptres, D) = 1 / focal length (m)

  7. Defects of Vision & Their Correction • Concave Lens: light rays diverge Power (Dioptres, D) = 1 / focal length (m) focal length is negative as focus is virtual (virtual image)

  8. Defects of Vision & Their Correction • Lens Formula: 1/f = 1/v + 1/u v = image distance, u = object distance M = v/u M = magnification (no units) • Myopia (short sightedness): cornea too curved or lens too powerful  distant object images form in front of retina and blur • Hypermetropia (long sightedness): eye not powerful enough  near object images form behind retina and blur

  9. Physics of the Ear • Sound: longitudinal wave • Acoustic impedance: density multiplied by the speed of sound in the material - low  conducts sound well - high  insulates sound well • Intensity: power per unit area (decreases with distance from source) Pinna: funnels sound waves into ear canal Canal: increases sound intensity Tympanic membrane vibrates Ossicles (three small bones) vibrate Strike oval window of the cochlea Nerve cells detect sound & convert it into electrical impulses for processing by the brain

  10. Physics of the Ear • Place Theory: brain determines pitch by noting the place on the basilar membrane where the message is strongest • Frequency Theory: frequency of vibrations of the basilar membrane as a whole is translated into an equivalent frequency of nerve impulses • Neurons, however, cannot fire as rapidly as the frequency of the highest-pitched sound  volley principle: nerve cells fire in sequence to send a rapid series of impulses to the brain Intensity is measured on the decibel scale:

  11. Physics of the Ear • Hearing Loss: - mechanical damage due to a blow on the head - disease (stop ossicles from moving) - exposure to excessive noise (tinnitus) - ageing

  12. Nerve Impulses • Electrical Signals in the Body: carried by neurones - cells have membrane potential: extra K+ ions inside, Na+ ions outside  potential difference = 70mV • When membrane is stimulated: - becomes permeable to Na+ions which diffuse due to the negative charge • Potential rises initially to 0 mV (depolarisation) & then to +30 mV (reverse polarisation) • Membrane becomes impermeable to Na+ ions & they are trapped within nerve cell • K+ions diffuse out of the membrane which restores the potential (repolarisation) • Process takes about 2 ms • Then the K+ions are pumped out, process takes about 50 ms

  13. Nerve Impulses • Pumps materials as a fluid quickly around body • Double circulatory system:

  14. Nervous Impulses Oxygenated blood enters through the pulmonary veins into the left atrium Deoxygenated blood enters through the vena cava into the right atrium It’s then pumped through a valve into the right ventricle chamber It’s then pumped through a valve into the left ventricle And then up through the pulmonary valve into the pulmonary artery towards the lungs And then through the aortic valve and out of the aorta to the rest of the body

  15. Nerve Impulses Arteries carry blood away from the heart at high pressurein thick walled lumen Capillaries have thin walls to allow glucose and oxygen to diffuse through Veins carry low pressure blood back to the heart. Veins have thinner walls and valves to prevent backflow of blood

  16. Nerve Impulses

  17. Nerve Impulses • Carry blood at high pressure • Outermost layer is composed of connective tissue • Media – smooth muscle cells and elastic tissue • Intima – in direct contact with flow of blood • Lumen – cavity in which blood flows

  18. Nerve Impulses • Most exchange of nutrients and gases takes place here • Small diameter, large surface area for diffusion • Lungs  carbon dioxide is exchanged for oxygen • Tissues  O2, CO2, nutrients and wastes are exchanged • Kidneys  wastes are released to be eliminated from body • Intestine  nutrients are picked up, wastes are released

  19. Nerve Impulses • Electrocardiogram (ECG): allows doctors to look at the electrical behaviour of the heart to diagnose problems - Body fluids transmit some of the electrical activity to the surface - Signals are reduced in size, with amplitudes of about 1mV - Suitable ECG output: patient must be relaxed so nerve cell activity does not disrupt data of electrical activity of heart P wave: depolarisation & contraction of the atria QRS wave: depolarisation & contraction of the ventricles T wave: re-polarisation and relaxation of the ventricles

  20. Ultrasound • Ultrasound: sounds above the audible frequency range for humans • Uses: non-invasive imaging, used to detect distances, depths and for medical purposes • Generation & Detection: ultrasound probe (transducer) generates & detects ultrasound waves, usually by use of a piezoelectric transducer. A voltage is induced when a quartz crystal is stretched or compressed, which can be large enough to create a spark. If a voltage is applied to a piezoelectric material, it changes shape. For an alternating voltage, the crystal will vibrate. Maximum energy transfer occurs when the crystal is in resonance

  21. Ultrasound • Ultrasound is often used to detect functions inside the body: • Ultrasound is: • longitudinal • passed through a gel on the skin to prevent reflection • reflected as it passes from one tissue to another (velocity change) • absorbed by tissue material • absorbed & reflected by many percentages depending on the tissue type • This determines an overall image when the wave is connected to a receiver

  22. Ultrasound • Resolution: distinction of image using ultrasound e.g. what distance in the body does a pixel on the monitor show? • higher frequency = better resolution • Axial: use short pulses; determined resolution in direction of beam • Lateral: use narrow pulses; determined by beam width • A-scan: amplitude modulated display • B-scan: brightness modulated display

  23. Ultrasound • Real time B-scan: moving images. Up to 100 probes are used • Movement of blood: through Doppler effect Advantages: • low frequency (low energy) beam • non-invasive & no discomfort • more effective than X-ray for images of soft tissue • portable equipment Disadvantages: • skilful operator & image requires skilful interpretation • image resolution is very easily reduced

  24. Medical Optics • Optical fibre: glass rod that conducts light by TIR • Light travels down a core surrounded by glass cladding: slightly lower refractive index (n)  prevents loss of light energy if the core passes into material of a higher refractive index • Snell’s Law: n1sinθ1 = n2sinθ2 • Critical Angle: sinθc = n2/n1

  25. Medical Optics • If the fibre is bent sharply  significant loss of light - radius of bend must be 20x diameter to prevent such losses • Fibre diameter: 10μm • Endoscope of 3mm diameter would have approx. 40 000 fibres • The more fibres, the greater the resolution sheath optical fibre fibre optic light guide

  26. Medical Physics • Uses of Endoscopy: • cut out diseased tissue • take a biopsy • seal a site of bleeding with heat • remove an obstructive object • keyhole surgery

  27. Medical Physics • LASER: light amplification by stimulated emission of radiation - When a photon of the right wavelength hits an excited atom of certain materials, it can stimulate the emission of a second photon of exactly the same wavelength and phase as the first - If enough atoms are excited, the photons can stimulate further emissions of further photons, all travelling in the same direction. - At one end of the material there is a mirror that totally reflects the photons, while at the other is a mirror that partially reflects the photons

  28. Medical Physics • Properties of lasers: - monochromatic (single colour) - coherent (in phase) - produce continuous light (pulses are caused by shutters) - absorbed by skin: increased by melanin - used in fibre optics to help guide light beam - CO2 lasers  cut away delicate tissue e.g. brain • Safety issues: - severe & deep burns caused by beams - beam shined into eye will cause blindness

  29. X-Rays • Uses - identify bone fractures - identify tooth decay - identify tumours & disease in soft tissue - treatment of tumours by radiotherapy • X-rays: photons of em radiation produced when a target of heavy metal is struck by electrons travelling at high speed. Approx. 1% of the electrons produce an X-ray photon  the rest is lost in heating up the target • Production of X-rays: - decrease velocity of electron or - remove an inner electron. Electrons replace the inner electron & photons are emitted as the electrons undergo transitions from different energy levels

  30. X-Rays • Maximum energy: all electron’s energy is converted into the photon’s energy - Kinetic energy = photon energy - Kinetic energy = charge of electron × voltage eV = hf h = Planck’s constant and… c = fλ so… eV = hc/λ

  31. X-Rays • Generation of X-rays: - rotating anode tube  evacuated glass tube, cooled in oil with a lead surround - Hot filament boils off electrons which are accelerated by anode voltage - hit target; most are released as heat, but few become X-ray - to prevent melting, target spins on a motor at 3000rpm

  32. X-Rays • Controlling the X-rays: - cannot be focused - sharp images are produced by small sources (point source) • Absorption of X-rays: occurs when x-rays pass through materials due to energy loss by… - Scattering: X-ray photons are reradiated as lower energy photons - Ejection: X-rays are ejected (photoelectric effect). Photons of visible light are emitted as atom comes out of the excited state - Compton Scattering: electron & lower energy X-ray photon are emitted - Pair Production: V. high energy photon interacts with atom’s nucleus. Electron & positron emerge, losing energy by ionisation until the positron is annihilated by an electron  generates 2 identical photons

  33. X-Rays • Dangers of X-rays: - water ionises to produce free radicals which produce H2O2 - enzymes & DNA are damaged - parts of cells are damaged - cell division is damaged ( mutations) - tissue & organ damage - life expectancy shortens - mutations cause gene alterations in populations • Attenuation of X-rays: - inverse square law: intensity reduces with distance I = I0e-μx

  34. X-Rays • Uses of X-rays: - diagnosis - treatment of cancers (radiotherapy) with high energy X-rays • X-ray workers… 1) wear a film badge to check the amount of radiation they get 2) wear lead aprons while the machine is in use 3) verify that the machine is in an enclosed room and the controls are in a separate room 4) ensure that that there is no entry into the X-ray room while the machine is in use

  35. Summary • The Eye • Defects of Vision & Their Correction • Physics of the Ear • Nervous Impulses • Ultrasound • Medical Physics • X-Rays

More Related