1 / 20

Review of τ -mass measurements at e + e - - colliders

Review of τ -mass measurements at e + e - - colliders. Introduction Current status of τ -mass measurements and μ τ -universality test New results from e+e- -colliders KEDR: τ -threshold experiment BELLE: the pseudomass method Conclusion. Yury Tikhonov (Budker INP)

arav
Download Presentation

Review of τ -mass measurements at e + e - - colliders

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Review of τ-mass measurements at e+e- -colliders • Introduction • Current status of τ-mass measurements and μτ-universality test • New results from e+e- -colliders • KEDR: τ-threshold experiment • BELLE: the pseudomass method • Conclusion Yury Tikhonov (Budker INP) Contents IHEP06,Moscow

  2. Introduction • Mass is a fundamental characteristic of a particle interesting by itself. • In case of τ-lepton the measurement of the mass mτ, the life time tτ and B(τ→ντeνe) provides the μτ-universalitytest : • Experimental methods: • τ-threshold experiment (BES, DELCO, KEDR)- this method is direct and • the most precise one in principle • Pseudomass method (CLEO, OPAL, BELLE)

  3. Current status of τ -mass measurements (PDG-2005) • The world average is dominated by the BES results • KEDR collaboration made analysis of the BES data and it was shown that the confidence interval quoted by BES was underestimated by factor 2÷1.5 (Nucl. Phys. B 144(2005)20) • BES collaboration did not agree with this statement (published in the same issue)

  4. Progress in μτ-universality test • Accuracy δmτ≈ 0.3 MeV seems sufficient now, but progress in precision • measurement of tτ and B (τ→ντeνe) will require more precise τ mass • This test based on only BES results

  5. KEDR / VEPP-4M τ-threshold experiment KEDR detector: • Vacuum chamber • Vertex detector • Drift chamber • TOF scintillation counters • LKr barrel calorimeter • Superconducting coil (6 kGs) • Muon tubes • Magnet yoke • CsI and cap calorimeter • Aerogel Cherenkov counters In operation since 2002

  6. Energy Calibration by resonant depolarization e- • Polarization beams prepared at VEPP-3 • Touschek (intra-beam scattered) electron pairs are detected with 2x2 scintillation counters • Two bunches compensation technique: scattering rates from unpolarized and polarized beams are compared Δ=(fpol –funpol )/fpol • The precision of the single energy measurement is ~2 keV (10-6 ) e-

  7. Measurement of J/ψ, ψ’, ψ’’ –masses at KEDR/VEPP-4M • During preparation of τ-threshold experiment the measurement of J/ψ, ψ’, ψ’’ meson masses has been performed ( PLB 573 (2003) 63, ICHEP2005): MJ/ψ= 3096.917 ± 0.010 ± 0.007 MeV Mψ’ = 3686.117 ± 0.012 ± 0.015 MeV Mψ’’= 3773.5 ± 0.9 ± 0.6 MeV Obtained relative precision ~(3÷5)·10-6 The precision was improved by 3-6 times compared to PDG value

  8. Measurement of the threshold behavior of the cross section is the most direct method of - mass determination. Scenario of τ-threshold experiment Narrow region is most sensitive to mass value high requirements on Ebeam, E accuracy and stability  Optimal luminosity distribution for 3-parameter fit: • 15% below the threshold (backround) • 70% ± 0.5 MeV around the threshold (mass) • 15% well above the threshold (detection efficiency)

  9. Problems with resonant depolarization in τ -energy region: • Integer spin resonance Ωspin=4ωrev at E=1763 MeV • Below 1780 MeV the polarization life time is very short Reasonable energy calibration rate is once per a few days

  10. Energy monitoring using Compton scattering of laser radiation • The method uses head-on interaction of CO2 laser radiation (λ=10.591 μm) with the electron beam. The energy spectrum of backscattered photons is measured by large-volume germanium detector(R.Klein at al.: NIM A384(1997)293, BESSY-I and BESSY-II) Accuracy of the energy determination is 80 keV for 20-minutes run.

  11. Beam energy spread can be measured by CBS(energy spread and its stability are very important for τ –threshold experiment!)

  12. VEPP-4M energy vs time CBS an RD difference Energy reconstruction accuracy ~80 keV

  13. Event selection • Events: ττ→eX with X =e,μ,π,K,ρ • Data: 3.9 pb-1 • Efficiency: ~ 2.25% • Background: 0+0.57 pb The measured crossections ψ’-peak

  14. The result of τ -massmeasurements at KEDR Free parameters: τ –mass, efficiency, background

  15. Systematic error estimates Next steps(end 06): -improving analysis The goals: -statistical error  ≤0.2 MeV -take more data -systematic  ≤0.1 Mev

  16. Measurement of τ-lepton mass by BELLE MC for input masses: Pτ Px 1.767 GeV1.777 GeV1.787 GeV  Pν Pseudomass method All in CMS Mmin M Mmin2 =Mx2 + 2( E – Ex )( Ex – Px ) E = Ebeam: beam energy, run dependence is correctedEx : hadron system energyPx : hadron system momentumMx : mass of the hadron system Fit result MC input mass We take threshold position a1as an estimator of the  mass.The shift a1 = a1– M was taken from the Monte Carlo.a1 = 0.70 ± 0.26 MeV.We apply this correction (0.7 MeV) to obtain the  mass from the fit of the data.

  17. Event selection • Events : e+e–+– • Data : 250 fb-1 (exp 7-37) • MC statistics  ½ of the data for   3 decay mode • Used decay modes :   3 ,   30Br(τ→ 3π ντ) = (9.47±0.10)%Br(τ→ 3π π0 ντ)= (4.37±0.09)% • The other  decays leptonically : τ  ℓ νℓ ντ • Event selection criteria: • Total charge = 0 • Number of leptons = 1 • Number of charged  = 3 • Number of 0 = 0 / 1 –

  18. Real Dataτ → 3π ντ Fit by function: (a3+a4·x)·arctg((x-a1)/a2)+a5+a6·x Mmin, GeV a1 =1777.41 ± 0.25 MeV

  19. Analyzing the pseudomass spectrum for decay τ → 3π ντ with the Belle detector at KEK gives the following results: Mτ = 1776.77 ± 0.13(stat.) ± 0.32(sys.) MeV (BELLE, preliminary) |Mτ+ – Mτ–|/Mτ < 2.8 · 10-4 @ 90% CL Systematic uncertainties • Calibration of the tracking detectors and knowledge • of the beam energy 0.26 MeV • 2. Choice of the fit range and the shape of the threshold function 0.18 MeV • 3. -decay misidentification and non +–negligible events • Total:0.32 MeV

  20. Conclusion • There is a real progress in τ-mass measurements at e+e- -colliders during last year(2 different methods were used by KEDR and BELLE): Mτ = 1776.71 ±0.13(stat.) ± 0.32(sys.) MeV (BELLE) Mτ= 1776.80 (stat.) ± 0.15(sys.) MeV(KEDR) Mτ =1776.99 MeV(PDG) +0.25 -0.22 +0.29 -0.26 • The improvement of accuracy is expected from KEDR soon • The combination of all data will significantly improve the • accuracy of PDG τ-mass value

More Related