1 / 19

Pulse Width Modulation

Pulse Width Modulation. PWM Features. General Features Four Channels, one 16-bit counter per channel, One common clock generator, providing 13 different clocks, One Modulo n counter providing eleven clocks, Two independent linear dividers working on modulo n counter output,

archana
Download Presentation

Pulse Width Modulation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pulse Width Modulation

  2. PWM Features • General Features • Four Channels, one 16-bit counter per channel, • One common clock generator, providing 13 different clocks, • One Modulo n counter providing eleven clocks, • Two independent linear dividers working on modulo n counter output, • Channel Programming • Independent enable/disable commands, • Independent clock selection, • Independent period and duty cycle, with double buffering system, • Programmable selection of the output waveform polarity, • Programmable center or left aligned output waveform.

  3. View of the external PWM’ Signals • 4 Multiplexed Channel outputs with PIOA lines • Dedicated high current output pad • Multiplexed to PA0, PA1 and PA2 (respectively for PWM0, PWM1 and PWM2) allow the user to drive external circuitry with load current up to 16 mA (instead of 8 mA for standard pads)

  4. PWM into the AT91SAM7S • PMC has to be programmed 1st for PWM to work: Clock Enabling • Set the PMC_PCER (Peripheral Clock Enable Register), bit 10 (PID10). • PIO Controller has to be programmed for the pins to behave as intended • Disable targeted PIO line(s) by using PIO_PDR (PIO Disable Register) as shown below • Select between Peripheral A or B, respectively, in PIO_ASR or PIO_BSR in order to select the PWM peripheral output channel(s) on the right pad(s).

  5. PWM CHANNEL PWM Architecture • The PWM Peripheral can be split up into two parts • 1°- The PWM Controller which is made of: • Clock Generator => Clock generation from the Master Clock (MCK) • Channel Control => Enable/Disable Channel • Interrupt Generator • 2°- Channel Modules: • Clock Selector • Channel Running Mode Manager • Duty Cycle and frequency Control • Counter value • Update register

  6. PWM PWMC: Clock Generator PWM_MR (Mode Register) 27 24 23 16 11 8 7 0 PREB DIVB PREA DIVA 1, ½,1/3,..,1/255 1, ½,1/3,..,1/255 CLKA MCK CLKB

  7. PWM PWM PWMC: Channel and Interrupt Management • At PWMC level, the user can, independently, enable/disable each channel PWM_DIS (Disable Register) PWM_ENA (Enable Register) 3 0 3 0 CHID3 CHID2 CHID1 CHID0 CHID3 CHID2 CHID1 CHID0 PWM_SR (Status Register) 3 0 CHID3 CHID2 CHID1 CHID0 • The user can use the same control panel at interrupt level plus the dedicated mask register PWM_IDR (Interrupt Disable Register) PWM_IER (Interrupt Enable Register) 3 0 3 0 CHID3 CHID2 CHID1 CHID0 CHID3 CHID2 CHID1 CHID0 PWM_IMR (Interrupt Mask Register) PWM_ISR (Interrupt Status Register) 3 0 3 0 CHID3 CHID2 CHID1 CHID0 CHID3 CHID2 CHID1 CHID0

  8. Set up the PWMC in your Application • Disable the PIO lines and select the right peripheral between A or B at multiplexing level. PIO and PWM lines • For power saving consideration, the PWM ‘s clock is stoppped at Power Management Controller level by default. Enable the PWM Clock • Set up the targeted clocks which will be used for the 4 PWM Channels. Set up the Clock Generator Channel Enabling • These tasks can be performed after the complete channel setting Interrupt Enabling

  9. PWM CHANNEL Set up a PWM Channel • Per channel: • Channel Mode Register: Select the running mode of the channel • Duty Cycle Register: 16-bit value to select the duty cycle of the signal • Period Register: 16-bit value to select the period of the signal • Counter Register: counter value • Update Register: Specific register to modify, synchronously, the Duty Cycle Register or the Period Register. PWM Channel 0,1,2 or 3 PWM Controller PeriodControl PWM pad Comparator Update Register Duty CycleControl CLKA ClockSelector CLKB MCK…. down to MCK/1024 Counter Interrupt

  10. CHANNEL First Step: Clock Choice PWM_CMR (Channel Mode Register) • At Channel level, the Channel Mode Register allows the user to choose between the 13 sources from the clock generator 3 0 CLKA CPRE CLKB Channel’sCounter ClockGenerator

  11. CHANNEL What is the best clock source ? • The PWM duty cycle quantum is the first criterion: • The user has to know his minimum requested accuracy at duty cycle level. The duty cycle control is managed through a 16-bit PWM_CDTY register. PWM_CDTY (Channel Duty Cycle Register) N value 15 0 CDTY • The duty cycle quantum depends on the value written in Period Register: • The M value is the required number of event in order to complete one PWM channel period (or half period in center-aligned mode) PWM_CPRD (Channel Period Register) M value 15 0 CPRD The PWM Channel period being equal to M source period. N will be from 0 up to M value. The higher M value, the higher the N value can be, the lower the quantum.

  12. PWM CHANNEL Example of different PWM accuracy • In this first choice, the duty cycle quantum will be 1/75 of a period Clock Generator CLKA Clock Generator on(/64) = Channel PeriodRegister = 75 750 kHz 10 kHz CLKB 48 MHz • For the same period, the duty cycle quantum will be 1/4800 of a period. Clock Generator CLKA Clock Generator on(1) = Channel PeriodRegister = 4800 48 MHz 10 kHz CLKB 48 MHz

  13. CHANNEL How to modify a channel Period or a channel Duty Cycle value ? • Before to enable the PWM Channel at PWM Controller level (PWM_ENA Register):The user will be able to write directly into the PWM_CDTYx or PWM_CPRDx of this channel, respectively, for a duty cycle or period change. • As soon as this PWM channel has been enabled:It is not possible to write into these previous registers. The user will have to use the Channel Update Register in order to modify one of the previous value. • The contain of the Update register is put into the PWM_CDTY or PWM_CPRD according to the value of CPD value in PWM_CMR PWM_CMRx (Channel Mode Register) 10 3 0 CPD CPRE PWM_CDTYx 0 PWM_CUPDx PWM_CUPDx 1

  14. CHANNEL Channel Update Register: PWM_CUPD • Why use it: • In running mode, modifying the duty cycle or the period value can be done only via PWM_CUPD, • The duty cycle or the period modification is going to be taken synchronously into account at the end of the period in progress, • How use it: • Before to write in PWM_CUPD, the user will have to be sure that the last write has been take into account. In other case, the previous data will be overlaid by the last one. • Use the bit CPD, in PWM_CMR register, in order to select a duty cycle or period modification, • Write the data into PWM_CUPD register. Note: It is not possible to modify, in the same PWM period for one channel, the duty cycle AND the period values.

  15. PWM CHANNEL PWM_CUPD Write method • Polling or interrupt methods can be used: • A flag rises after an end of channel period (channel 1 for example) PWM_ISR (Interrupt Status Register) • Reading PWM_ISR automatically clears CHIDx flags 3 0 CHID3 CHID2 CHID1 CHID0 0 0 0 0 PWM_ISR (Interrupt Status Register) 3 0 CHID3 CHID2 CHID1 CHID0 0 0 1 0 • Modifying duty cycle or period value in channel 1 can be possible without overlaying risk at PWM_CUPD level.

  16. CHANNEL First Working Mode: Left-aligned PWM_CMR (Channel Mode Register) When the PWM Counter reach the period value, it is cleared. 9 8 CALG=0Lelt-Aligned Mode CPOL PWM_CPRD PWM_CDTY 0 CPOL= 0 CPOL= 1

  17. CHANNEL Left-aligned Limitation in Multi-Channel use • The left-aligned working mode does not allow to avoid overlapped transition in Multi-channel use In Left-aligned Mode:One event depends on the duty cycle value and the other depends on the period value.For the same period, there will be overlapped event PWM_CPRD0 PWM_CDTY0 Channel 0Output The period of both Channels are equal (PWM_CDTY0 - PWM_CDTY1) Channel 1Output PWM_CPRD1 PWM_CDTY1

  18. CHANNEL Second Working Mode: Center-aligned PWM_CMR (Channel Mode Register) 9 8 CALG=0Lelt-Aligned Mode CPOL PWM_CPRD Count down Count up PWM_CDTY 0 CPOL= 0 CPOL= 1

  19. CHANNEL Center-aligned: Non-overlapped event Method • The center-aligned working mode allows to avoid overlapped transition in Multi-channel use PWM_CPRD0 PWM_CDTY0 Channel 0Output (PWM_CDTY0 - PWM_CDTY1) Channel 1Output PWM_CPRD1 PWM_CDTY1