290 likes | 499 Views
Quantum Energy Hot Water Heat Pump Solutions. Cost efficient, Green solutions through World Class Technology for generation of hot water up to 60 – 70 deg C. Quantum Energy Technologies Pty Ltd. ABOUT QUANTUM – OUR PRINCIPLE FOR THIS PRODUCT
E N D
Quantum EnergyHot Water Heat Pump Solutions Cost efficient, Green solutions through World Class Technology for generation of hot water up to 60 – 70 deg C. Quantum Energy Technologies Pty Ltd
ABOUT QUANTUM – OUR PRINCIPLE FOR THIS PRODUCT One of the oldest heat pump water heater (HPWH) manufacturer’s from Australia, Over 30 years history Quantum started at the end of 1970’s based on the research from the University of Melbourne. Market leading technology with focus on development and new product/ application design. New modular variable output technology Quantum – Hot Water From Thin Air 2
Quantum Products A. QUANTUM HEAT PUMP WATER HEATERS (Q-HPWHs) A.2 Q-HPWH Commercial Models (double wall)
Centrifugal Fan Quantum Products A.2 Q-HPWH Commercial Models (double wall)
CONVENTIONAL METHOD USES DIESEL OR GAS TO GENERATE HOT WATER EXHAUST CO2 AND SO2 & NO2 – UNFRIENDLY TO ENVIRONMENT NEED HIGHER MAINTEANANCE NEED TO STORE OIL ALL THE TIME CARRYING OIL NEED PUMP AND STORAGE HEAT PUMP USES ELECTRICITY TO GENERATE HOT WATER NO EMMISSIONS LOWER MAINTENANCE AND USER FRIENDLY YEARLY REFRIGERANT NEED TO BE CHARGED NO STORAGE REQUIRED HOW IT IS DIFFERENT THAN BOILER..
HEAT PUMP TECHNOLOGY The System A hot water heat pump system consists of Compressor, Condenser, Expansion device, and Evaporator. Expansion Valve Qh Qc Qc ≤Qc+W W Condenser W Evaporator Compressor Quantum – Hot Water From Thin Air 7
Compressor draws refrigerant gas and raises its P and T by compression so the gas temperature is at a level where it can easily heat the water. Condenser allows heat exchange between hot gas and the water by direct heat transfer. Expansion device releases the P of the refrigerant liquid which decreases refrigerant temperature. In Evaporator the cool refrigerant absorbs heat from heat source (e.g., ambient air), and boils to low T vapor. Quantum – Hot Water From Thin Air 8
Heat pump‘pumps’ heat from a low T subject to a high T subject, much like a water being pumped to higher level. Heat pump has heat outputs ( power) greater than power it consumes, so it is also an ‘energy amplifier’) Subject to be Heated (High T) Qh (≤Qc+W) W Heat Pump Qc Low T Heat Source Quantum – Hot Water From Thin Air 9
Heat Pumps for Hotels • Sized according to total daily demand / peak period demand • Sized according to available storage capacity • ROI Installed less than 2 years • Average 100MT Carbon Dioxide reduction per annum • Where possible install such that existing assets are maintained on standby basis. • “N+1” basis / modular design
Quantum Products A.4 QWH-Hydro Source – cont 2– Advantages Unique design. Making chilled water directly and hot water at the same time. Super efficient. Saves up to 85% of energy. Four-stage heating, cold water in and hot water out, less flow rate and circulations, saves the power consumed by water circulating pump. By-pass for each stage. Therefore if some stage(s) in service, the rest stages still can operate. ~65oC hot Water out Cold Water in I II III IV 13oC A/C Water in 8oC Chilled Water out Quantum – Hot Water From Thin Air 15
Some Projects―Royal Crowne Plaza, Singapore • A 5 starhotel, 495 room • 145,000 Lt/day @ 55-56°C Quantum – Hot Water From Thin Air 16
Some Projects―Royal Crowne Plaza,Singapore High running cost: USD $1.80/(m3 water) High maintenance cost: USD$8,000/annum Unable to comply with pollution regulation Original • 2 oil boilers, 3 water tanks • 24 years old, low efficiency Quantum – Hot Water From Thin Air 17
Some Projects―Royal Crowne Plaza,Singapore Lower operational cost: USD$0.80/m3, Cooling of140-150kW used for cooling plant room Fuel Oil saving: 128,665 Litres Maintenance Cost saving: Gross Financial saving: USD $131,006 Payback on investment: 1.36 yrs 10 yrs + Installation Quantum • 30 x 340-TI-E units , and 1 x 2ton water tank • Project Cost: USD$125,300 Quantum – Hot Water From Thin Air 18
Some Projects―Lindeman Is. , Australia • Lindeman Island QLD – Hundreds of Titan & Compact heaters installed. (above) Quantum – Hot Water From Thin Air 19
Case Examples Mercure Ancol Mercure Sanur Bali Ibis Slipi Hotel F-1 Cikini Build up of a sample case
SAVING PER YEAR (MERCURE ANCOL) SAVING PER YEAR = Annual cost of Diesel – Annual cost of electricity by using Heat Pump = US $ 110,769 - US $ 21,610 - US $ 6,603 = US $ 82,556/ Year Say = US $ 83,000 per year
Some Awards • Global 100 Eco-Tech Awards (Japan) 2005 - Heat Pump Hot Water Production • Master Builders Association (MBA) National Energy Awards 2000- Materials Manufacturing • SEDA Energy Smart Green Globe Awards 2000- Red Globe Recipient • National Energy Innovation Award 1988 - Outstanding Achievement in Innovative Energy Production R&D • Australian Financial Review New Product & Technology Expo 1986- Most Innovative Domestic Product And many more• • • • • •