MARKET DEVELOPMENTS IN COMMERCIAL REFRIGERATIONThe last two decades Significant GWP of HFC refrigerants demanded efforts to reduce the greenhouse gas effect resulting from these substances refrigerant charges reduced system tightness improved Situation better but no real long term way forward numerous supermarket refrigeration systems with different natural refrigerants, some with secondary refrigerant- / waste heat circuit, realised
climate protection: EU F-gas regulation, national regulations economic aspects: Raising energy and F-gas cost energy efficiency: EU legislation (ErP) coming into play MARKET DEVELOPMENTS IN COMMERCIAL REFRIGERATION Market drivers
Based on collected experiences CO2 DX emerged as state of the art solution in food retail stores today MARKET DEVELOPMENTS IN COMMERCIAL REFRIGERATION
STORES IN OPERATIONOctober 2011 Pilot Stores Series YTD October 2011313 Stores in operation(181 YTD PY) 34,6 MW MT capacity (21,5 MW PY) 4,5 million operating hours (509 Years) Sweden (9) Norway (16) Finnland (2) United Kingdom (6) Denmark (43) Germany (137) Netherlands (8) Poland (2) Luxembourg(1) Czech Republic (10) Switzerland (72) Slovakia (2) Austria (2) Hungary (2) Italy (1) First CO2OLtec Installation in Switzerland in 2004
-49% STORES IN OPERATIONOctober 2011 YTD October 2011313 Stores in operation(181 YTD PY) 34,6 MW MT capacity (21,5 MW PY) 4,5 million operating hours (509 Years) Sweden (9) Norway (16) Finnland (2) United Kingdom (6) Denmark (43) Germany (137) Netherlands (8) Poland (2) Luxembourg(1) Czech Republic (10) Switzerland (72) Slovakia (2) Austria (2) Hungary (2) Italy (1) Environmental Impact CO2 equivalent(tons) Cumulated reduction of CO2 emissions 81.300 tons or* 24.100 X * Average car using 0,12Kg CO2/km; run time 15.000 km per year
CO2 DX-REFRIGERATING SYSTEMSGeography CO2 DX systems today Oslo 5°C Attractive energy performance at average annual temperatures up to +15 °C in line with EPEE statement and energy data recording Berlin 9°C Prag 8°C Lyon 12°C Bordeaux 12°C Budapest 11°C Triest 14°C Milano 13°C Porto 14°C Marseille 14°C Belgrad 12°C Florenz 15°C Madrid 14°C Barcelona 15°C Sofia 11°C Rom 16°C Valencia 17°C Tirana 16°C Thessaloniki 16°C Málaga 18°C Athen 18°C
CO2 DX-REFRIGERATING SYSTEMSGeography CO2 DX systems today Oslo 5°C Attractive energy performance at average annual temperatures up to +15 °C in line with EPEE statement and energy data recording Berlin 9°C Prag 8°C Lyon 12°C Bordeaux 12°C Budapest 11°C Triest 14°C Milano 13°C Porto 14°C Marseille 14°C Belgrad 12°C Florenz 15°C Madrid 14°C Barcelona 15°C Sofia 11°C Rom 16°C Valencia 17°C Tirana 16°C Thessaloniki 16°C Málaga 18°C Athen 18°C
CO2 DX-REFRIGERATING SYSTEMSGeography CO2 DX systems next generation Oslo 5°C Attractive energy performance across Europe Berlin 9°C Prag 8°C Lyon 12°C Bordeaux 12°C Budapest 11°C Triest 14°C Milano 13°C Porto 14°C Marseille 14°C Belgrad 12°C Florenz 15°C Madrid 14°C Barcelona 15°C Sofia 11°C Rom 16°C Valencia 17°C Tirana 16°C Thessaloniki 16°C Málaga 18°C Athen 18°C
Thank you for your attention! Company restricted information Carrier has the right refrigerant for every application, but every application will not have the same refrigerant solution.