An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Solar Protection Relays&Energy MonitoringPRODUCT FEATURES BCJ Controls

  2. Solar protection relays ComAp MainsPro ABB CM-UFD.M33 ComAp InteliPro PV

  3. Solar generation & load monitoring eGauge EG3000-016 Blue’Log X-Series

  4. ComAp MainsPro Product Features: • Flexible supply voltage and measurement range • Suited for standard DIN rail installation or door-mount • User friendly interface with easy setting (no software tools needed) • Simple wiring with removable connectors • Remote binary communication • Compact design for installation in restricted spaces

  5. ComAp MainsPro Product Features: • Lost of Mains function and history track function (Last 5 events history log) • Integrated mechanical lock to secure your settings • Breaker failure protection • Watchdog relay output • Increased resolution of frequency protection settings • Resistance to frequency jumping

  6. ABB CM-UFD.M33 Characteristics • – Monitoring of voltage and frequency in single-phase and three-phase mains (2-wire, 3-wire or 4-wire AC systems) • – Over- and undervoltage, 10-minutes average value as well as over- and underfrequency monitoring • – Two-level threshold settings for over-/undervoltage and over-/underfrequency • – ROCOF monitoring and vector shift detection are configurable • – Interrupted neutral detection • – Default settings in accordance with Great Britain Engineering Recommendations G59/3 and G83/2

  7. ABB CM-UFD.M33 Characteristics • – True RMS measuring principle • – All threshold values and tripping delays are adjustable • – Error memory for up to 99 entries (incl. cause of error, measured value, relative timestamp) • – Password setting protection • – 3 control inputs (e.g. for feedback signal, remote trip) • – 3 c/o (SPDT) contacts • – Multiline, backlit LCD display

  8. ComAp IntelliPro PV Features • Dynamic grid support • Directional reactive power undervoltage protection • Many frequency, voltage, and current protections • Compatible with ComAp PC tools • Possible to enable the appropriate functions required by your utility • Detailed history log completely records the nature of mains disturbances including brown-outs • Watchdog reporting provides better reliability of the installation

  9. ComAp IntelliPro PV Features • Advanced online communication notifies instantly of changes in the mains-connection • Door-mount possibility with clear graphical display • Password protection for full security • Features new Pole Slip protection • Certified according to IEC 60255, VDE 0126-1-1 and BDEW • Applicable for requirements of G59/3, G10, G83 and IEEE1547 and VDE-AR-N 4105

  10. EGAUGE EG3000-016 SPECS: • 1% Accurate (Compliant to ANSI C12.1) • Solid State Memory Records: • 1 second granularity for 10 minutes • 1 minute average for 1 year • 15 minute average for 30 years • Up to 12 Circuits on 3-phases (120V−480V, 50−60Hz).

  11. EGAUGE EG3000-016 SPECS: • 3 + N Voltage Inputs to measure reactive power. • Data can be accessed on a remotely through the in-built web-server. The online display is updated every second, giving instant data on any load or generation changes. It records the most recent 30 years of data in the built-in solid-state memory. • Web connection - ethernet required (another model is available which uses ethernet over power - call for details) • This unit requires specific CTs to function. Get in contact for advice on the ideal set up.

  12. BLUE'LOG X-SERIES SPECS • Supply voltage: 20 - 60 V DC • Current consumption: typically 5 W • Operating temperature: -20 - 70°C • Protection class: IP 20 • Dimensions: 110 x 148 x 63 mm • Installation:Wall installation, Top-hat rail installation in electrical distribution board, in control cabinets • Modem: Ethernet connection (10 / 100 MBit)

  13. BLUE'LOG X-SERIES SPECS • Display/operation:1 x display (291 x 118 pixels)3 x LED2 x operating buttons + 1 directional pad1 x reset button3 x DIP switches for bus termination • Communication:2 x RS485/RS422 (auto-detection)1 x CAN4 x digital/analog inputs (dry contact, S0, voltage input (0 - 24 V, 0 - 1 V, 0 - 100 mV)current input (0 - 20 mA), PT1000, configurable via software)4 x digital outputs (open collector max. 60 V/100 mA or voltage output max. 200 mA; configurable via software)4 x digital inputs (dry contact, for e.g. ripple control receiver, S0, configurable via software)

  14. BCJ Controls • At BCJ Controls we produce Secondary Protection Switchboards with solar protection relays for Commercial Solar over 30kW grid connections. • BCJ Controls - commercial solar network protection unit - switchboard manufacturing including protection relay & anti-islanding and zero export devices • BCJ Controls is a solar technology company set up by ex-utility industrial sparkies. Between them they have a large amount of experience in electrical grid protection, as well as dealing with utilities on a day-to-day basis.

  15. Visit us: BCJ Controls 2,17 Lorraine St, Peakhurst NSW Australia2210 (02) 9534 8465 www.bcjcontrols.com.au