1 / 14

EFIT Design and Transient Analysis M. Schikorr, E. Bubelis EUROTRANS: DM1 WP1.5 : “Safety”

EFIT Design and Transient Analysis M. Schikorr, E. Bubelis EUROTRANS: DM1 WP1.5 : “Safety” Madrid , 13-14 November 2007. Topics:. Design Criteria for EFIT-Pb 2. EFIT design data for Transient Analysis 3. Some EFIT-Pb results to the ULOF transient.

Download Presentation

EFIT Design and Transient Analysis M. Schikorr, E. Bubelis EUROTRANS: DM1 WP1.5 : “Safety”

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EFIT Design and Transient Analysis M. Schikorr, E. Bubelis • EUROTRANS: DM1 WP1.5 : “Safety” • Madrid , 13-14 November 2007 EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  2. Topics: • Design Criteria for EFIT-Pb 2. EFIT design data for Transient Analysis 3. Some EFIT-Pb results to the ULOF transient EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  3. 1. Some important EFIT Design Criteria: • Use of MgO-based MA-MOX Fuel Mixture • Operate EFIT at k_eff ~ 0.95 - 0.97 with flat k_eff burnup characterisitics • Adopted 3-Core region design to obtain flat radialpower profile (designed by ENEA and ANSALDO) • Design core and primary system in such a manner to allow sufficient natural convection flow rate to sustain a ULOF transient for at least 30 minutes without „large number“ of pin failures (via gas blowdown) • Account for burn-up and protective oxide layer formation during operation of plant EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  4. EFIT ULOF Design Criteria requires : Assure a sufficiently large natural convection flow rate ( > 25 % nominal flow) under ULOF-ss conditions. This implies : 1. keep pressure drop across the core „low“ (~<0.75 bar) by selecting an appropriate fuel pin / subassembly design 2. minimize pressure losses throughout the primary / DHR system such that total system pressure loss <~ 1.0 – 1.1 bar 3. assure a height differential between the core midplane and the heat sink midplane of at least > 2.00 m EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  5. Keeping DP_core in the XT-ADS Design low: • Select an appropriate pin / sub-assembly design by optimizing the pin diameter, pin pitch, wrapper dimensions etc. • Minimize the number of grid-spacers and optimise design • Keep the length of the fuel pin low • Optimize inlet and outlet support structures to keep pressure drops small EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  6. Most current EFIT Design Data: Inner Core Region, Core Zone 1 EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  7. Most current EFIT Design Data: Intermediate Core Region, Core Zone 2 EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  8. Most current EFIT Design Data: Outer Core Region, Core Zone 3 EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  9. Other EFIT Data Inputs: 854mm lower gas plenum 274mm upper gas plenum EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  10. EFIT-Pb: Avg and Peak Cladding and Fuel Temperatures at Nominal and ULOF-ss Plant Conditions for BOC and EOC EOC state is defined to be max burnup ~ 100 MWd/kg of MOX-MA fuel EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  11. ULOF: BOC, Peak Pin, 6 Spacer @ 0.50mm thickness 2. ULOF: EOC, Peak Pin, 6 Spacer @ 0.50mm thickness, 100 um oxide EFIT ULOF Transient Cases Analysed: EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  12. EFIT-Pb : ULOF, BOC, Peak Pin, 6 Spacer @ 0.50mm thickness, no oxide Conclusion: For current design EFIT peak pin clad will NOT fail under BOC conditions even though of flow undershoot that is ~ 22 % nom. flow. Min Clad Failure Time ~ 17 hours EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  13. EFIT-Pb : ULOF, EOC, Peak Pin, 6 Spacer @ 0.50mm thickness, 100um oxide Conclusion: For current design EFIT peak pin clad will most likely NOT fail under EOCconditions even though of flow undershoot ~ 22% (min. clad failure time ~ 1000 sec). Peak pin fission gas pressure will be </~ 100 bar. EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

  14. 1.) The ULOF transient is less sensitive in the Pb-cooled EFIT design than to the XT-ADS design because of its better natural convection characterisitcs: (38% of nominal flow for EFIT-Pb compared to ~ 25% nominal flow for the XT-ADS under ULOF-steady state conditions). 2.) The current design of the Pb-cooled EFIT system achieves the design goal of sustaining a ULOF transient for at least 0.5 hours without pin failures. Conclusions on EFIT ULOF Transient : EUROTRANS WP1.5 Safety Meeting : Madrid, Nov 13-14. 2007

More Related