90 likes | 301 Views
5 ft 3 V-blender w/ Spectrometer. Brimrose 5030 wireless process spectrometer collection parameters:. Spectra are collected once every rotation at 23 rpm Tilt sensor triggers spectrometer about 10 ° before bottom 12 spectra are collected and averaged every rotation
E N D
5 ft3 V-blender w/ Spectrometer Brimrose 5030 wireless process spectrometer collection parameters: • Spectra are collected once every rotation at 23 rpm • Tilt sensor triggers spectrometer about 10° before bottom • 12 spectra are collected and averaged every rotation • Collection time is 0.45 sec or 62° for 12 spectra off 62° on
Tablet Validation V-Blend MgSt Dispersion 2 ft3 V-blending for 6 minutes 5 mg
Tablet Validation V-Blend MgSt Dispersion 2 ft3 V-blending for 6 minutes 5 mg
Blend Monitoring-NIR Process Spectrometer Romaco blender lid w/ Brimrose 4030 spectrometer mount and sapphire window
Tablet Validation Final Blend 1500L Bin Tumbled for 5 min 15 mg Dotted line represents theoretical MgSt w% of 0.84%
Tablet Validation Final Blend 1500L Bin Tumbled for 5 min 15 mg
Use of NIR During Large Scale Blending 200 ft3 Double Cone Blender outfitted with Brimrose Luminar 4030 AOTF NIR Spectrometer Brimrose 4030 wireless process spectrometer collection parameters: • Spectra are collected once every rotation at 13 rpm • Tilt sensor triggers spectrometer about 10° before bottom • 12 spectra are collected and averaged every rotation • Collection time is 0.51 sec or 40° for 12 spectra off on 40°
API Content in 200 ft3 Double Cone, 13 RPM Target = 49% API RSD in 200 ft3 Double Cone, 13 RPM API Blending w/NIR Monitoring – Conc. & C.U. RSD Initial Blend CU RSD = 1.1% Model Parameters: Wavelengths 1-601 Sample 21-80 1 PC 1st Derivative Gain = 1