DCNNG Multi CCU System Setup DCNNG MCCU System Setup
DCNNG Multi CCU System Setup • A basic multi-CCU system. • The following can be connected to a multi-CCU system: • A maximum of 30 DCN-CCU devices. • A maximum of 4000 delegate positions (Stand-alone and Microphone function only). • A maximum of 1500 delegate positions with PC control. • A maximum of 32 audio channels (1 Floor and 31 channels for Interpretation). DCNNG MCCU System Setup
RS 232 PC Control AutoDome Ethernet link Optional DCN-NCO CCU 1 Seat 1 Seat 245 CCU 2 Seat 246 Seat 490 For redundancy only DCNNG Multi CCU System with 490 Concentus units • Up to 245 addresses can be connected to one CCU. • All active units use an address. (Concentus Units are active units) DCNNG MCCU System Setup
RS 232 PC Control AutoDome Ethernet link Optional DCN-NCO CCU 1 Seat 1 Seat 245 CCU 2 Seat 246 Seat 426 IDESK 1 IDESK 64 Audio Expander DCNNG Multi CCU System with 426 Concentus units and 64 Interpreter Desks • Up to 245 addresses can be connected to one CCU. • All active units use an address. (Concentus Units and Interpreter desks are both active units) DCNNG MCCU System Setup
RS 232 PC Control AutoDome Ethernet link Optional DCNNG Multi CCU System with 490 Concentus units and # Interpreter Desks • Up to 245 addresses can be connected to one CCU. • All active units use an address. (Concentus Units and Interpreter desks are both active units) DCN-NCO CCU 1 Seat 1 Seat 245 CCU 2 Seat 246 Seat 490 CCU 3 1 n DCNNG MCCU System Setup
DCN-NCO Room 1 CCU 1 1 n 1 n Room 2 CCU 2 Room 3 CCU 3 1 n 1 n 1 n 1 n DCNNG Multi CCU System Single Room or combined Rooms • Up to 245 addresses can be connected to one CCU. • All active units use an address. (Concentus Units and Interpreter desks are both active units) • Interlock between booths on separate CCU‘s cannot be used in “None” - mode. DCNNG MCCU System Setup
RS 232 PC Control AutoDome Ethernet link Optional DCNNG Multi CCU System up to 1225 seats • Up to 245 addresses can be connected to one CCU. • DCN Dual Delegates Units use an address.Each unit controls two seat numbers. DCN-NCO CCU 1 Unit 245 Unit 1 Seat 1 & 2 Seat 489 & 490 CCU 2 Unit 245 Unit 1 Seat 491 & 492 Seat 979 & 980 CCU 3 Unit 245 Unit 1 Seat 981 & 982 Seat 1224 & 1225 DCNNG MCCU System Setup