240 likes | 379 Views
Yeongduk Kim Sejong University. The Status of KIMS (Korea Invisible Mass Search). ICHEP 2012 , Melbourne . 2012. 7. 6. Yangyang (Y2L) Underground Laboratory. (Upper Dam). Korea Middleland Power Co. Yangyang Pumped Storage Power Plant. Y2L. Seoul. (Power Plant). RENO.
E N D
Yeongduk Kim Sejong University The Status of KIMS(Korea Invisible Mass Search) ICHEP 2012, Melbourne 2012. 7. 6
Yangyang(Y2L) Underground Laboratory (Upper Dam) Korea Middleland Power Co. Yangyang Pumped Storage Power Plant Y2L Seoul (Power Plant) RENO (Lower Dam) KIMS (Dark Matter Search) AMoRE (Double Beta Decay Experiment) Minimum depth : 700 m / Access to the lab by car (~2km)
KIMS KIMS overview • Similar experiment to DAMA. • Direct comparison to DAMA annual modulation signal is possible. Iodine is common to both exp. WIMP CsI(Tl) Mineral Oil (30cm) &Muon det. Nucleus Lead (15cm) WIMP-Nucleus elastic scattering Polyethylene (5cm) Copper (10cm) CsI(Tl) crystal CsI(Tl) Crystal 8x8x30 cm3 (8.7 kg) +3” PMT (9269QA)
Characteristics of CsI(Tl) for WIMP Search • High light yield ~5 photoelectrons/keV • Pulse shape discrimination (PSD) Background discrimination. • 133Cs, 127I (SI cross section ~ A2) • Both 133Cs, 127I are sensitive to SD interaction • Notorious 137Cs contaminations are controlled. (not dominant background anymore ! ) – Ultrapure CsI powders are developed and available from Chemetall company. electron recoil nuclear recoil
Data with 12 crystals • 12 crystals (104.4kg) installed in the Cu shield. • 2.5 year data (Sep. 2009 – Feb. 2012) • Background Level : 2~3 cpd/kg/keV • Source calibration with 55Fe & 241Am • 1 year of data (Sep. 2009 – Aug. 2010) published with PSD analysis. • Backgrounds are well understood. Total backgrounds Multiple –hit backgrounds Data MC
Analysis with PSD We calculate the mean time of FADC signal, and take logarithm of it. Our PSD parameter
Limits on nuclear recoil rates Bayesian method was used to estimate the NR rates. S.C. Kim et al., PRL 108 181301 (2012) Example : 6 keV bin, DET09 Total weighted limits for 1keV bin. RED : 1 sigma limit BLACK : 90% CL limit 3.6-5.8 keV (2-4 keV in DAMA) 90% CL limit is 0.0098 cpd/kg/keV < 0.0183 cpd/kg/keV signal of DAMA
Cross Section Limits S.C. Kim et al., PRL 108 181301 (2012) SI cross section limit SD cross section limit
Annual Modulation Signals are (de)claimed. DAMA CDMS didn’t see annual modulation. arXiv:1203.1309 COGENT
Annual Modulation Studies (w/o PSD) • Total DAQ rate is under 6Hz . • 2.5 year data to see annual modulation ; 75.53 ton∙days • The temperature of detector array is 20 - 21.6 OC depending on the position, and it is maintained stably with a maximum fluctuation of around 0.2 OC. Sep. 2009 ~ Feb. 2012
3-6 keV • Annual modulation amplitude is obtained including the exponential decay of 134Cs. • Annual modulation amplitude is consistent with null. • The 90% upper limit of the amplitude is comparableto DAMA’s annual modulation signal (0.0189 cpd/kg/keV) • We are trying to give final numbers shortlyin this summer.
Studies on Quenching Since electronic stopping power of WIMP nuclear recoil has similar values of alpha (electronic) stopping power, we can use these data. No parameter adjusted. Recent claim of Chicago group on low quenching factor will be tested. Cs/I in CsI(Tl) e p TRIM MARLOWE Electronic stopping power range of recoil Cs,I • Stopping power of ions : TRIM, MARLOWE • Scintillation efficiency : measured with alphas. J.H. Lee IEEE (in print)
Studies on Channeling Motivated by DAMA’s initial studies on channeling. KIMS may lose some nuclear recoil events by PSD cut due to channeling effect -Eur. Phys. J. C. 53, 205 (2008) Bozorgnia et al., JCAP11, 029(2010) Due to the blocking of recoil ions, channeling fraction in CsI(Tl) < 2%.
Experimental Setup DAQ : 3 Coincidence trigger of Neutron generator, Neutron Detector and CsI(Tl) Neutron Detector 60 * 100 mm CsI(Tl) 30*30*14 mm Neutron Generator 1100 mm Recoil Energies () 2.4 MeV Monoenergetic n 500 s Recoil ions 50 s 50 s Neutron pulses
Simulation & Measurements Preliminary Partial channeling ? ER Black data RedNuclear recoil events in GEANT4+Malowe Blue Gamma contaminated events in GEANT4+Malowe Due to very low event rate, we need more statistics to compare spectra of different recoil angle tagged by each neutron detector. A single crystal is aligned. Very little channeling (<<1%) is observed.
Upgrades I : Low Radioactive PMTs • PMT : 0.4-0.9 cpd Cf. Internal : 0.7-1.2 cpd • U, : 0.2-0.4 137Cs : 0.3-0.5 • Th : 0.1-0.25 134Cs : 0.05-0.3 will be less • K : 0.15-0.25 U,Th : 0.01 Unit: mBq/PMT • High K content in the PMT is at the coupling of Quartz and Borosilicate glasses at the center of PMT body. • The Cherenkov lights from 40K decay in the glass or weak glass scintillation may be the origin of the PMT noise. • With new PMT, we can reduce ~ 1cpd/kg/keV
Upgrade II - Pure NaI(Tl) crystal • It is possible to add several NaI(Tl) crystals to KIMS. • We try to develop low background NaI(Tl) crystals from scratch in collaboration with Sigma-Aldrich company & DM-ICE group. • Sigma-Aldrich company made first low-K NaI powder in June 2012. Both DM-ICE and KIMS will measure the powders. Normal powder : ~ 0.3 ppm of K.
Summary • 1 year data with 100 kg CsI(Tl) data analyzed with PSD method. DAMA Iodine region is inconsistent with KIMS NR rate limit. • Stringent limit of spin-dependent proton cross section is given. • 2.5 year data is analyzed without PSD for annual modulation null modulation limit comparableto the level of DAMA’s modulation amplitude : final numbers are underway. • Channeling & quenching factor studies generates first data. • Upgrade plans show further reduction of backgrounds.
KIMS (Korea Invisible Mass Search) Seoul National University: H.C.Bhang, J.H.Choi, S.H. Choi, K.W.Kim, S.C.Kim, S.K.Kim, J.H.Lee, J.I.Lee , J.K.Lee, M.J.Lee, S.J.Lee, J.Li, X.Li, S.S.Myung,S.L.Olsen, I.S.Seong Sejong University: U.G.Kang, Y.D.Kim Kyungpook National University: H.J.Kim, J.H.So, S.C.Yang Yonsei University: M.J.Hwang, Y.J.Kwon EwhaWomansUniversity: I.S.Hahn Seoul City University : Douglas Leonard Korea Research Institute of Standard Sciences : Y.H.Kim, K.B.Lee, M. Lee Tsinghua University : Y.Li, Q.Yue, J. Li
Background spectra Multiple compton event rates Raw Single rates
Surface alphas • Surface alpha response studied with intentional Rn contamination. • Measured low energy events of contaminated crystal tagged by alphas of the other crystals. A is a crystal contaminated w/ Rn. B is a clean crystal. A B signal
Upgrade I : PMT PMT noise is serious problem for WIMP search. 3” Metal + Quartz window PMT. High Quantum efficiency. Two PMTs will be delivered in June 2012. Disadvantage : Expensive. QE is similar to RbCs & SBA for CsI
Upgrade III: AMoRE-DARK AMoRE is a project of 100 kg 40Ca100MoO4 bolometer. For Dark Matter, 40CanatMoO4 Can be run simultaneously in AMoRE. Cf. CRESST – CaWO4