1 / 9

Rigidity-dependent cosmic ray energy spectra in the knee region obtained with the GAMMA experiment

GAMMA Experiment. Rigidity-dependent cosmic ray energy spectra in the knee region obtained with the GAMMA experiment. 4 Y.Gallant, 1 A.Garyaka, 2 A.D.Erlykin 5 L.Jones, 1 R.Martirosov, 2 N.Nikolskaya, 3 J.Procureur, 1 S.Ter-Antonyan. 1 Yerevan Physics Institute

bat
Download Presentation

Rigidity-dependent cosmic ray energy spectra in the knee region obtained with the GAMMA experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GAMMA Experiment Rigidity-dependent cosmic ray energy spectra in the knee region obtained with the GAMMA experiment 4Y.Gallant, 1A.Garyaka, 2A.D.Erlykin 5L.Jones, 1R.Martirosov,2N.Nikolskaya, 3J.Procureur, 1S.Ter-Antonyan 1 Yerevan Physics Institute 2 Moscow Physics Institute 3 Centre d Etudes Nucleaires Bordeaux-Gradignan, 4 Universite Montpellier II 5 University of Michigan Astroparticle Physics 28/2 (2007) 169/ arXiv: 0704.320v1 [astro-ph]

  2. GAMMA Experiment GAMMA Facility • Location: • Armenia, Mt.Aragats • 3200 m a.s.l. • EAS array: • 33x3 (1x1x0.05) m3+ • +9 (0.3x0.3x0.05) m3 • Muon hall: • 2500 g/cm2 of rock • 150 (1x1x0.05)m3 • EAS data: • Nch > 5 105 (100%) • R < 25 m (50 m) •  < 300 • N(R<50m) > 103 • E > 5 GeV • T = 6.2107 sec

  3. GAMMA Experiment Measurement errors and particle spectra Ln(Nch ) 0.1, s0.05, x,y0.5-1m,  1.50 Ln(N ) 0.35-0.2 at N(R<50m)103-105 Particle density spectra Single particle spectra Ri < 50 m 15 detectors

  4. Detector response CORSIKA(EGS,NKG) NA=200, A  p, He, O, Fe • s(7m < ri < 90m)

  5. GAMMA Experiment CORSIKA6.031(NKG) Simulated database: WA(EA , X) {A, EA}  X(Ne , Nµ , Nh , s , x0 , y0 , θ, ) Emax= 500PeV  = -1.5  < 300 R < 25m Ee,> 1 MeV E > 150 MeV Muon hall: E > 4 GeV (e,FLUKA)

  6. EAS Inverse Problem: 1)Combined Analysis, nd.f.= 350 2)2D-Analysis, F(X) d2F/dNedN , nd.f.= 240 3)4D-Analysis, F(X) d4F/dNedNdsdcos, nd.f.= 1640

  7. Primary energy spectra SIBYLL Results of 1-2D Combined Analysis 1 = 0.0950.008 [m-2s-1sr-1TeV-1] 2 = 0.100.012 3-16 = 0.0430.007 (O - like) 17-26 = 0.0240.004 (Fe - like) ER = 2500200 TV 2/nd.f.2.0 B.Wiebel & P.Biermann, 24th ICRC (1995) A.Lagutin et al., 29th ICRC (2005)

  8. Verification Enlarged EAS data (R<50m) Knee positions Test of KASCADE primary energy spectra by GAMMA EAS data WZ(E,X) fZ(E) dE = F(X) z • fp , fHe , fO=fC+fSi , fFe

  9. GAMMA Experiment Conclusion • The obtained primary energy spectra strongly depend on interaction model. • The SIBYLL interaction model is more preferable. • Rigidity-dependent spectra describe the EAS data at • least up to E~100 PeV. • All-particle primary energy spectrum slightly depends on interaction model. • The energy spectra of primary nuclei disagreewith the same KASCADE data in 1-100 PeV energy range, however, the discrepancies of the all-particle energy spectra obtained by the GAMMA and KASCADE are sufficiently small (~20%).

More Related