JEOL 7000F. Exploring the JEOL Control Program. Goals. Look at all of the menu items and their functions. Note where icon brings up the same function. Look at any items not in menu but brought up by icons and vice versa. Other items of interest?. Basic Screen. Title Bar. File Menu - 1.
E N D
JEOL 7000F Exploring the JEOL Control Program
Goals • Look at all of the menu items and their functions. • Note where icon brings up the same function. • Look at any items not in menu but brought up by icons and vice versa. • Other items of interest?
File Menu - 1 • User Login • Image File Handling • We will look at elsewhere • Image Save As … • Quick Save Options • Auto Batch Export • Print - NO PRINTER • Exit
File Menu - User Login • Advantage is storage of your individual image observation conditions. • List of users. • Login as user brings up password.
File Menu - Image Save As … • Brings up the fairly typical “Save As” Dialog Box.
File Menu - Auto Batch Export • Allows transfer of image files in a batch. • Non-exported files do not contain associated text and scale bar on the image.
Edit Menu • Copies the image to the clipboard. • Example, the can be pasted to MS Paint
Control Menu • Column • Contrast/Brightness • Need live image • Use knobs on JEOL Operation Pad • Add Images • Alignment • See JEOL Operation Pad • We will discuss later
Control Menu – Column 1 • Column Control can be reached either through the Control Menu pull down or, • Clicking the Column Icon on the Tool Bar.
Control Menu – Column 2 • Accelerating Voltage • High-light and type in new value • Click arrows • From 0.5 – 2.9 kV steps are 0.01 kV • From 3.0 – 30 kV steps are 0.10 kV • OL Aperture • Set to the same value as the OL Aperture on column • For most users, almost always “4”
Control Menu – Column 3 • SEI Detector • Usually On (green) • Mode • Sets the bias on the Faraday cage in front of the SE scintillator. • Normally at “3” but set to a lower value if using high beam currents (Large spot sizes).
Control Menu – Column 4 • Column Mode: • SEM - Leave it here (green) • ECP – Electron channeling - No body does this now. • ALP – Alignment usage for service engineer. • Focus: • Can course focus using the numbers and slide • Probe (beam) current: • Higher the number the more current in the electron beam hitting the sample.
Control Menu – Column 5 • Scan Rotation: • Normally this is OFF (0) • DFC • Almost always OFF
Control Menu – Add Images • Allows mixing of different signals. • For example, backscattered and secondary electron. • Not often used.
Image Menu – General – 1 • Image File Handler … • Display Thumbnails • Self explanatory • Use 24 Bits for Export • Self explanatory • Save to AnalySIS • AnalySIS is an imaging database program. • Select SIS Database
Image Menu – General – 2 • Show Pan Window with 2K Image • Opens pan window with large 2k x 2k images • Overlap … • Overlaps 2 images • Contrast/Brightness/Gamma … • Image Processing • Various image filters
Image Menu – Image File Handler • Several ways to get there: • Icon on Tool bar • Image menu • File Menu
Image File Handler – 1 • Select a folder for saving images, • Print - No printer • Export • Adds scale bar and other information to stored image • Much easier to use theAuto Batch Exportin the File Menu drop down if you have many images you want to export. • Other options are generally self explanatory
Image File Handler – 2 • Saw this window before in looking at the File Menu. • You see the same thing if you go to File Menu, then Image Save As
Image Menu – Contrast/Brightness/Gamma • Tool bar icon • Histogram • Gray scale • Gain adjustment slider • Correction curve • Hi – Lo Thresholds • Linearize – Equalize – Invert • Contrast/Brightness/Gamma Sliders
Tools Menu • Annotate and Measurement • Add and edit text • Measure distance between two arbitrary points • Cursor Measurement • Measures distance between two points specified by the cursor.
Tools Menu – Annotate and Measurement • Append Annotate and Measure • USE ICON • Load Annotate and Measure • Loads saved text • Save Annotate … • Saves the text created • Delete All Annotate … • Deletes all text and figures on the screen • Set Measurement …
Stage Menu • Exchange • Control • Map Control • Motion Abort • ESC Key stops movement of the stage. • Alarm Recovery • If specimen holder comes in contact with a detector then Alarm Sounds; holder stops.Alarm Recovery frees stage to move
Stage Menu – Exchange • Described previously • Specimen Exchange operations
Stage Menu – Control • Step Movement of the stage • Relative position indicator • Stage movement operation • STOP & Center buttons • Stop – stops stage movement • Center – moves to specimen exchange
Stage Menu – Map Control • Snap Shot • Designate an observation range on a saved image, then move the stage to the range • Stage Map • Movement of stage through Points File orStage Map
Setup Menu • Recipe Setup • Operation • Stage • User Login • Sets user login conditions
Maintenance Menu • Normally these should not be altered. • Gun • Stage • JEOLS … • for JEOL engineer only
Other Items • REPLACE ALL TOOLS • Dispose of trash • Leave the lab in good order. • LOG IN / LOG OUT • Note any problems