1 / 21

Sensor Calibration Automation Demonstration

Sensor Calibration Automation Demonstration. Presenters: Barbara Benson and David Balsiger (University of Wisconsin) Collaborators:  Laurence Choi, Yu Hen Hu, Paul Hanson, Tim Kratz, Tim Meinke (University of Wisconsin); Ken Chiu (SUNY-Binghamton). Motivation. Example from current practice:

belden
Download Presentation

Sensor Calibration Automation Demonstration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Sensor Calibration Automation Demonstration Presenters: Barbara Benson and David Balsiger (University of Wisconsin) Collaborators:  Laurence Choi, Yu Hen Hu, Paul Hanson, Tim Kratz, Tim Meinke (University of Wisconsin); Ken Chiu (SUNY-Binghamton)

  2. Motivation • Example from current practice: • Sensor calibration: • Due to sensor drift, the Greenspan dissolved oxygen (DO) sensor requires frequent (once every two weeks) calibration services. • Sensor data correction: • After the DO sensor is calibrated, the observed data since last calibration need to be adjusted accordingly.

  3. Problem: • Both tasks are performed manually • Labor-intensive process • Does not scale-up well • Solution  Automation • Steps toward automation • Web interface for technician, information manager • Calibration agent integrated into data flow

  4. New Calibration Method • Old Method • The Greenspan is manually pulled out of the water and rested for an hour to allow it to stabilize. • The time, air temperature and barometric pressure are recorded and a “correction factor” is estimated manually. • Proposed New Method • A calibrated DO sensor is placed manually next to the existing un-calibrated DO sensor in the water and records data in parallel during “calibration”. • The data recorded from both sensors are entered into a calibration program to calculate “correction factor” automatically. • Potential Benefit • Shorter calibration time • Semi-automated procedure

  5. Data “Calibration Period”

  6. Steps • Development of computer program modules for the algorithms for calculating the “correction factor” and correcting data • Design of user interface for technician or information manager to execute algorithms

  7. “Calibration” Algorithms • Calculating correction constant • Correct un-calibrated data using estimated correction factor

  8. Future steps • Extend the program to access the Oracle database for data retrieval and updating • Integrate web interface with the portal • Develop calibration agent(s) • Sensor service manager • Calibration event manager • Data calibration manager

  9. Automated Scaling and Data Processing in a Network of Sensors Collaboration with computer scientists at UCSD, Indiana, and SUNY-Binghamton and computer engineering colleague at UW-Madison Growing the Sensor Network: Agents and Remote Code Deployment Calibration Agent NSF NEON Grant: Addressing the Scaling Challenge

  10. Calibration Agent(s) • Will detect calibration event • Handle sensors being swapped • Retrieve or capture “calibration” data • Calculate the correction factor • Retrieve data to be corrected • Correct data and load corrected data to the database • Write event data to calibration log in the database

  11. A Work In Progress …