210 likes | 823 Views
Bioequivalence of Highly Variable Drugs: Regulatory Perspectives. Sam H. Haidar, R.Ph., Ph.D. Pharmacometrics Office of Generic Drugs. Potential Advantages. Reduction in regulatory burden Facilitate market access for highly variable but safe and effective drugs
E N D
Bioequivalence of Highly Variable Drugs: Regulatory Perspectives Sam H. Haidar, R.Ph., Ph.D. Pharmacometrics Office of Generic Drugs
Potential Advantages • Reduction in regulatory burden • Facilitate market access for highly variable but safe and effective drugs • Make it easier to approve a generic drug product which is significantly less variable than the reference listed drug
Current BE* RequirementsMajor Regulatory Agencies • U.S. Food and Drug Administration (FDA) • Health Canada • Committee for Proprietary Medicinal Products (CPMP), Europe • National Institute of Health Sciences (NIHS), Japan *BE = Bioequivalence
Current BE Requirements FDA* • AUC: 90% Confidence Interval Limits 80-125% • Cmax: 90% Confidence Interval Limits 80-125% • Criteria applied to drugs of low and high variability *Guidance for Industry: Bioavailability and Bioequivalence Studies for Orally Administered Drug Products- General Considerations
Current BE Requirements Health Canada • AUC: 90% Confidence Interval Limits 80-125% • Cmax: Mean T/R ratio (point estimate) between 80-125% • Criteria judged flexible enough to deal with highly variable drugs* *Expert Advisory Committee on Bioavailability and Bioequivalence, June 26 – 27, 2003.
Current BE Requirements CPMP* • AUC: 90% Confidence Interval Limits 80-125% • Cmax: 90% Confidence Interval Limits 80-125% • Cmax: “In certain cases a wider interval is acceptable (e.g., 75-133%) *Note for Guidance on the Investigation of Bioavailability and Bioequivalence, January 2002
Current BE Requirements NIHS (Japan)* • AUC: 90% Confidence Interval Limits 80-125% • Cmax: 90% Confidence Interval Limits 80-125% • In cases of failure, add-on studies are acceptable (provided other criteria are met) *Guideline for Bioequivalence Studies of Generic Drugs, December 22, 1997.
Performance of FDA Criteria • Survey of ANDA Applications (1996-2001) • Evaluated distribution of Cmax and AUC T/R mean ratios (point estimates)
Summary • Although criteria allows for a mean difference of ± 20%, the vast majority of submissions were within ± 10% • This was also true with regard to highly variable drugs and drug products • Additional confirmation of greater variability associated with Cmax
Available OptionsBioequivalence of Highly Variable Drugs • Scaling based on intra-subject variability (Cmax, AUC) • Expansion of regulatory limits
Scaling Approaches • Reduction in sample size • Limits are defined by degree of variability • Need for point estimate constraint?
Expansion of Limits • Cmax only, or Cmax and AUC • Fixed Limits (e.g., 70 – 143%) for drugs meeting high variability “criterion” • Need for point estimate constraint? • Major concern: How to classify borderline drugs and drug products
Expansion of LimitsStudy: Hauck et al.* • AUC: 90% Confidence Interval Limits 80-125% • Cmax: 90% Confidence Interval Limits 70-143% • Outcome: Sample size reduced by 60% • Cmax ratios of 128% could pass using the 70-143% limit *Hauck et al. Int J Clin Pharm Ther. 39 (8) pp. 350-355 (2001)
Conclusion • If a need to make changes in the regulations is concluded: • Either approach would result in significant reduction in sample size • Additional criterion constraining point estimates may be needed • Based on prior experience, clustering around a T/R ratio of 1 would be expected for a modified BE criteria for highly variable drugs
Q & A • Dale Conner, Pharm.D.