Numerical and Analytical models for various effects in EDFAs

TEL AVIV UNIVERSITY THE IBY AND ALADAR FLEISCHMAN FACULTY OF ENGINEERING Department of Electrical Engineering – Physical Engineering. Numerical and Analytical models for various effects in EDFAs. Inna Nusinsky-Shmuilov. Supervisor:Prof. Amos Hardy. Outline:. Motivation

Download Presentation

Numerical and Analytical models for various effects in EDFAs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TEL AVIV UNIVERSITY THE IBY AND ALADAR FLEISCHMAN FACULTY OF ENGINEERING Department of Electrical Engineering – Physical Engineering Numerical and Analytical models for various effects in EDFAs Inna Nusinsky-Shmuilov Supervisor:Prof. Amos Hardy

  2. Outline: • Motivation • Rate equations • Homogeneous upconversion • EDFA for multichannel transmission • Inhomogeneous gain broadening • Conclusions

  3. Motivation: • Applications in the 1.55μm range wavelengths • Optical power amplifiers • Low noise preamplifiers in receivers • Multichannel amplification (WDM) Why EDFAs? Why analytical models? • Insight into the significance of various parameters on the system behavior. • Provide a useful tool for amplifier designers. • Significantly shorter computation time.

  4. doped fiber Amplified Signal output Pump Forward pumping Pumping geometry: - Forward pumping - Backward pumping -Bidirectional pumping

  5. Rate equations: Energy band diagram:

  6. Pump absorption and emission Spontaneous emission Signal emission Homogeneous upconversion Signal absorption Rate equations: Second level population:

  7. Rate equations: Stimulated emission and absorption Spontaneous emission Pump emission ,absorption and ESA Scattering losses Scattering losses Signal, ASE and pump powers:

  8. The ASE spectrum is divided into slices of width • Boundary conditions: -knownlaunched signal power -knownlaunched pump power Numerical solution of the model: • Steady state solution (/ t = 0) • The equations are solved numerically, using an iterations method

  9. acceptor donor Homogeneous upconversion: Schematic diagram of the process:

  10. Homogeneous upconversion: Assumptions for analytical solution: • Signal and Pump propagate in positive direction • Spontaneous emission and ASE are negligible compared to the pump and signal powers • Strong pumping (in order to neglect 1/τ) • Loss due to upconversion is not too high

  11. Homogeneous upconversion: Signal and pump powers vs. position along the fiber: Solid lines-exact solution Circles-analytical formula Dashed lines-exact solution without upconversion • Approximate analytical formula is quite accurate Injected pump power 80mW Input signal power 1mW

  12. Homogeneous upconversion: Dependence of upconversion on erbium concentration: • Good agreement between approximate analytical formula and exact numerical solution X Analytical formula is no longer valid

  13. Homogeneous upconversion: Upconversion vs. pump power: Input signal power 1mW • Strong pump decreases the influence of homogeneous upconversion • If there is no upconversion (or other losses in the system), the maximum output signal does not depend on erbium concentration • Approximate analytical formula’s accuracy improves with increasing the pump power

  14. Homogeneous upconversion: Upconversion vs. signal power: Injected pump power 100mW • Increasing the input signal power decreases the influence of homogeneous upconversion • Approximate analytical formula’s accuracy improves with increasing the input signal power power

  15. Multichannel transmission: Assumptions for analytical solution: • All previous assumptions • Interactions between neighboring ions (e.g homogeneous • upconversion and clustering) are ignored (C2=0) • Spectral channels are close enough • For example: • for a two channel amplifier in the 1548nm-1558nm • band the spectral distance should be less than 4nm • For 10 channels the distance should be 1nm or less

  16. Multichannel transmission: Signal powers vs. position along the fiber: 3 channel amplifier, spectral distance 2nm: 10 channel amplifier, spectral distance 1nm: • Good agreement between approximate analytical formula and exact solution of rate equations Solid lines-exact solution Circles-analytical formula

  17. Multichannel transmission: 3 channel amplifier, spectral distance 4nm: 5 channel amplifier, spectral distance 2nm: X Analytical formula is no longer valid • Approximate analytical formula is quiet accurate • The accuracy of the analytical formula improves with decreasing spectral separation between the channels

  18. Multichannel transmission: Output signal vs. signal and pump powers: • The approximate solution is accurate for strong enough input signals and strong injected power. • If input signal is too weak or injected pump is too strong, the ASE can’t be neglected.

  19. Multichannel transmission: • The analytical model is used to optimize the parameters of a fiber amplifier. Optimization of fiber length: • Approximate results are less accurate for small signal powers and smaller number of channels. • Optimum length is getting shorter when the input signal power increases and the number of channels increases.

  20. is the shift in resonance frequency Inhomogeneous gain broadening: Energy band diagram:

  21. All energy levels are shifted manifold is shifted by the same amount from the ground ( ). • A photon of wavelength , interacts with molecules with shifted cross-sections and , due to the frequency shift of . • is the number of molecules, per unit volume, whose resonant frequency has been shifted by a frequency that lies between and . • The function is the normalized distribution function of molecules, such that . Usually a Gaussian is used. • The width of determines the relative effect of the inhomogeneous broadening. Inhomogeneous gain broadening: The model:

  22. Inhomogeneous gain broadening: Aluminosilicate Germanosilicate Single channel amplification: • The inhomogeneous broadening is significant for germanosilicate fiber whereas aluminosilicate fiber is mainly homogeneous Solid lines-inhomogeneous model Dashed lines-homogeneous model

  23. Inhomogeneous gain broadening: Germanosilicate Aluminosilicate Multichannel amplification: • There is significant difference between inhomogeneous broadening (solid lines) and homogeneous one (dashed lines) for both fibers. • The channels separation is 10nm, which is larger than the inhomogeneous linewidth of the germanosilicate fiber and smaller than the inhomogeneous linewidth of the aluminosilicate fiber.

  24. Inhomogeneous gain broadening: Germanosilicate • If we decrease the channel distance in germanosilicate fiber to 6nm (less than ), we expect the effect of the inhomogeneous broadening to be stronger. Multichannel amplification: • Here the inhomogeneous broadening mixes the two signal channels and not only ASE channels, thus its influence on signal amplification is more significant.

  25. Inhomogeneous gain broadening: Experimental verification of the model: Germanosilicate fiber: Circles-experimental results Solid lines-numerical solution using inhomogeneous model Dashed lines- numerical solution using homogeneous model

  26. Conclusions: • Numerical models have been presented, for the study of erbium doped fiber amplifiers. • Simple analytical expressions were also developed for several cases. • The effect of homogeneous upconversion, signal amplification in multi-channel fibers and inhomogeneous gain broadening were investigated, using numerical and approximate analytical models • Numerical solutions were used to validate the approximate expressions. • Analytical expressions agree with the exact numerical solutions in a wide range of conditions. • A good agreement between experiment and numerical model.

  27. Suggestions for future work: • Time dependent solution • Modeling for clustering of erbium ions • Considering additional pumping configurations and pump wavelengths • Experimental analysis of inhomogeneous broadening

  28. Publications: • 1.Inna Nusinsky and Amos A. Hardy, “Analysis of the effect of upconversion on signal amplification in EDFAs”, IEEE J. Quantum Electron.,vol.39, no.4 ,pp.548-554 Apr.2003 • 2. Inna Nusinsky and Amos A. Hardy, ““Multichannel amplification in strongly pumped EDFAs”, IEEE J.Lightwave Technol., vol.22, no.8, pp.1946-1952, Aug.2004

  29. Acknowledgements: • Prof. Amos Hardy • Eldad Yahel • Irena Mozjerin • Igor Shmuilov

  30. Appendix:

  31. Appendix: Homogeneous upconversion: Assumptions for analytical solution: Strong pumping: where

  32. Appendix: Homogeneous upconversion: Assumptions for analytical solution: Homogeneous upconversion not too strong: where

  33. Appendix: Homogeneous upconversion: Derivation of approximate solution: We ignore the terms of second order and higher:

  34. Appendix: where is derived from: Homogeneous upconversion: Rate equations solution without upconversion:

  35. Appendix: Homogeneous upconversion: Approximate analytical formula:

  36. Appendix: Multichannel transmission: Assumptions for analytical solution: Strong pumping:

  37. Appendix: Multichannel transmission: Approximate analytical solution :

  38. Appendix: Definitions of parameters:

  39. Parameters used in the computation: Homogeneous upconversion:

  40. Parameters used in the computation: Inhomogeneous gain broadening: