Top Quality Stop Check Valves Manuafactured By Maniks

MSCA are check valves with a built-in stop valve function. MCHV are check valves only. MSCA / MCHV are available in angle way versions. The valves are designed to open at very low differential pressures, allow favourable flow conditions and are easy to disassemble for inspection and service.

Download Presentation

Top Quality Stop Check Valves Manuafactured By Maniks

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Top Quality Stop Check Valves Manufactured by Maniks http://www.maniks.com

  2. About Us • Maniks is the most reputed Indian brand with a history of 30 years for manufacturing reverse jet pulse valves used in bag-filter applications and the sequential timers used in conjunction with them. These are used in dust collector equipment for cement, steel and such other industries. The company was started by Mr. ShekharKulkarni, an IIT Mumbai alumnus, with a vision to substitute imported products with Indian make products. The primary aim was to produce reliable products with excellent quality and service. http://www.maniks.com

  3. Introduction • What is Stop Check Valves ? • Specifications of Stop Check Valves • Working principal • Working of Stop Check Valves • Basic part of Stop Check Valves • Main features of Stop Check Valves • Applications • Maniks Client http://www.maniks.com

  4. Stop Check Valves • What is Stop Check Valves ? • MSCA are check valves with a built-in stop valve function. MCHV are check valves only. MSCA / MCHV are available in angle way versions. • The valves are designed to open at very low differential pressures, allow favourable flow conditions and are easy to disassemble for inspection and service. • The MSCA is equipped with vented cap and has internal back-seating enabling the spindle seal to be replaced whilst the valve still under pressure. • Laser cut V-ports provide excellent opening characteristics (MSCA / MCHV 50-125). http://www.maniks.com

  5. Stop Check Valves Specifications of Stop Check Valves • Butt-weld DIN (EN 10220)- ME 15 - 125 (½ - 5 in.) • Butt-weld ANSI (B 36.10 Schedule 80), - ME 15 - 40 (½ - 1½ in.) • Butt-weld ANSI (B 36.10 Schedule 40), - ME 50 - 125 (2 - 5 in.) • Socket-weld ANSI (B 16.11),- ME 50 (2 in.) http://www.maniks.com

  6. Stop Check Valves Working principal http://www.maniks.com

  7. Stop Check Valves • Working of Stop Check Valves • The valve must be mounted vertically with the cone downwards. The valve is designed to resist very high internal pressure. However, the piping system in general should be designed to avoid liquid traps and reduce the risk of hydraulic pressure caused by thermal expansion. • For further information refer to installation instructions for MSCA-X/MSCHV-X. If cold refrigeration oil having low viscosity enters and settles in the damping chamber, problems with the check valve may arise. Consequently, it may be necessary to modify the valve for more viscous liquids by enlarging the hole to the damping chamber. http://www.maniks.com

  8. Stop Check Valves • TECHNICAL DATA : • Refrigerants : Applicable to HCFC, HFC, R717(Ammonia) and R744 (CO2). For further information refer to the product instruction for MSCA-X/MSCHV-X. • Temperature range : -60/+150°C (–76/+302°F). • Max. working pressure 52 bar g (754 psig). http://www.maniks.com

  9. Stop Check Valves Packing gland (MSCA-X) : The "full temperature range" packing gland is the standard for the entire MSVL platform. This ensures perfect tightness throughout the whole temperature range : –60/+150°C (–76/+302°F). Damping chamber : The chamber is filled with refrigerants (gas or liquid), which provides a damping effect when the valve opens and closes. http://www.maniks.com

  10. Stop Check Valves • Main features • Reliable Function • Better Performance • Ease Of Maintenance • Lower Power Consumption • Faster Reaching of Peak Pressure • Preventing air loss • Ease of installation • Better flow characteristics http://www.maniks.com

  11. Stop Check Valves Applications • Stop Check Valves is used in different field such as • Carbon Black Industry • Asphalt Plants • Chemical Plants • Cement And Rock Industry • Food Industry • Foundries • Iron & Steel Industry • Tobacco Industry To Get more Information visit us @ http://www.maniks.com/stop-check-valves.html http://www.maniks.com

  12. Stop Check Valves • Maniks Top Satisfied Client List http://www.maniks.com

  13. Stop Check Valves Thank You http://www.maniks.com