An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TIA-1005 (Proposed by TR-42.9)Industrial Cabling StandardPete LockhartAnixterManufacturing IT ForumCleveland, OhioMay 20-21, 2008

  2. Key Points to be Covered • Definition of Structured Cabling for Commercial Networks • Definition of Structured Cabling for Industrial Networks • The proposed TIA-1005 Draft Standard Structure • Industrial Area Concepts • Recognized cables • Recognized connectivity • The Automation Outlet • 2-Pair Cabling • Multi-connector Ethernet Channels • M.I.C.E.

  3. Structured Cabling 1st Defined in TIA/EIA-568

  4. ANSI/TIA-PN-3-4822-G 12-12-2007 Telecommunications Infrastructure Standard for Industrial Premises • Ballot proposal from TIA-TR-42.9 working group • Will become ANSI/TIA-1005 Industrial Cabling Standard on approval • Based closely on the ANSI/TIA/EIA 568-B, TIA-569-B, ANSI-J-STD-607-A, ANSI/TIA/EIA-606-A, and ISO/IEC 11801Standards • Also related to ISO/IEC 24702 Information Technology-Industrial Premises • Environmental references: IEC60721-x, IEC60654-x

  5. Purpose of Standard • To enable the planning and installation of telecommunications cabling infrastructure within and between industrial buildings • The potential exposure to hostile environments in the industrial space is the central concept of the standard in contrast to that of TIA/EIA 568, which addresses commercial buildings • The special cabling system requirements of industrial operations is also a prime design principle of the document

  6. New Terms, not in TIA/EIA-568B • Automation island • Area in proximity to the industrial machines • Automation outlet • Where the generic telecommunications cabling ends and the automation-specific cabling begins • Device area • Where system I/O interacts with control equipment • Industrial segment • A point-to-point connection between two active industrial communications devices • M.I.C.E. • For Mechanical, Ingress, Climate/Chemical, Electromechanical

  7. Horizontal Topology Same as TIA/EIA-568B

  8. Industrial Area Concept • Control/equipment/telecomm room • Factory floor • Work area • Automation island

  9. Industrial Horizontal Star Channel Topology TO = Telecommunications Outlet AO = Automation Outlet

  10. Horizontal Allowable Distances for Copper Links • In many cases industrial cabling can be made almost entirely of work area cabling, which must be accounted for when combined with equipment and patch cabling in the limited 100 m (328 ft.) channel. • The following formula must be used to calculate the maximum cord and link lengths:

  11. Recognized Horizontal Cables • Twisted-pair copper • 4-pair, 100 ohm balanced (unshielded or shielded) • 2-pair, 100 ohm balanced (unshielded or shielded) • Optical fiber • Optical (glass) fiber, single-mode and multimode cable (ANSI/TIA/EIA-568-B.3) • Plastic Optical Fiber: Removed from the issue of the Standard and referred to a Working Group for later addition as an Addendum • Plastic polymer optical fiber (ISO/IEC 24702) • Plastic polymer clad silica optical fiber (ISO/IEC 24702)

  12. Horizontal Cabling Beyond the Automation Outlet • The Automation Outlet demarks the point at which non-generic horizontal cabling components maybe used. • The 2-pair, 100 ohm balanced cabling may not be used prior to the Automation Outlet. Must be 4-pair Can be 2-pair AO

  13. Recognized Backbone Cables • Copper • 4-pair, 100 ohm balanced (unshielded or shielded) • Optical fiber • Optical (glass) fiber, single-mode and multimode cable (ANSI/TIA/EIA-568-B.3) • Plastic Optical Fiber: Removed from the issue of the Standard and referred to a Working Group for later addition as an Addendum. • Plastic polymer optical fiber (ISO/IEC 24702) • Plastic polymer clad silica optical fiber (ISO/IEC 24702)

  14. Grounding and Bonding Considerations • Use ANSI-J-STD-607-A for grounding requirements • Use single point grounds • Grounding and bonding should be configured to provide an equal potential grounding system to prevent ground loops • The use of star grounding in communications coverage areas can be used to mitigate ground loops

  15. Industrial Cabling Performance • Industrial cabling performance • Requires a combination of environmental and enhanced transmission performance to support the intended applications • The standard states • That for the above reasons and because Channels with more than four connections are allowed – Category 6, or better, cabling SHOULD be used

  16. Industrial Cabling Performance Requirements • Twisted-pair copper • The installed channels and permanent links shall meet the requirements for cabling as specified for • Category 5e per ANSI/TIA/EIA-568-B.1, clause11.2 • Category 6 per ANSI/TIA/EIA-568-B.2, clause 7

  17. Industrial Cabling Performance Requirements • Standard optical fiber cables • Optical fiber (glass) cabling shall meet the performance requirements of ANSI/TIA/EIA-568-B.1. Depending on the environmental conditions additional enhancements or separation/isolation may be required.

  18. Connecting Hardware – Copper • Telecommunications outlet/connector • 8-position modular: (100 ohm balanced twisted pair) per ANSI/TIA/EIA-568-B.1 using T568A 0r B wiring method • Non-Sealed: 4-pair terminated, must meet the performance requirements of ANSI/TIA/EIa-568-B.2 • Sealed: may be housed (encapsulated) within a protective housing, must meet the performance requirements of ANSI/TIA/EIa-568-B.2, when subject to the applicable environmental conditions – defined by MICE Table

  19. Connecting Hardware – Copper • Automation outlet/connector • Serves as the interface between generic cabling and the automation island • 8-position modular: (100 ohm balanced twisted pair) per ANSI/TIA/EIA-568-B.2 required to meet Category 6 or better • Non-sealed: each 100-ohm 4-pair cable shall terminate on an 8-position connector • Sealed: shall use connector encapsulation variant 1 from IEC 61076-3-106

  20. Connecting Hardware – Copper • Automation outlet/connector • A 2-pair sealed connector. Where a full set of applications is not required (100BASE-T max), the M12-4 D-coding connector as defined in IEC 61076-2-100 may be used. It should be a minimum of Category 5e for four connections or less and Category 6 for more than four connections. M12-4 ‘D’ Jack M12-4 ‘D’ Plug

  21. Connecting Hardware – Fiber Optic • Telecommunications outlet connector • LC connector family, as specified in ANSI/TIA/EIA-604-10A and shall perform to ANSI/TIA/EIA-568-B.3 • Sealed optical fiber connectors, may be protected by encapsulation, isolation or separation. Variant 1 of IEC 61076-3-106 methods should be used, but any suitable encapsulation may be used, as long as a single method is used throughout the facility.

  22. Connecting Hardware – Fiber Optic • Optical fiber automation outlet/connector • Non-sealed: LC connector family, as specified in ANSI/TIA/EIA-604-10A and shall perform to ANSI/TIA/EIA-568-B.3 • Sealed: the sealed outlet connector housing shall be Variant 1 of IEC 61076-3-106, incorporating the duplex LC connector of ANSI/TIA/EIA-604-10A

  23. Adapters • Balanced twisted pair • Back-to-back jack is recommended for use on enclosures for bulkhead quick connections. • Mated adapters shall conform to the transmission requirements of the appropriate media type and category • When two connections are used in very close proximity, they should be of the next higher performance category. If the space is less then 10 cm, it can count as a single connection. L < 10cm L > 10cm

  24. Consolidation Point • Interconnection point within the horizontal cabling using ANSI/TIA/EIA-568-B.2 or -B.3 compliant connecting hardware in accordance with the requirements of Clause 0 • Differs from a MUTOA as it requires an additional connection point • No more than a single consolidation point or transition point shall be used in the same horizontal run • Each cable extending to the work area from a consolidation point shall be terminated to a compliant TO, AO or MUTOA

  25. Consolidation Point Examples

  26. Annex A: Requirements for 2-pair Cabling • All unused conductors of a 4-pair cable shall be common mode terminated • When connecting a complete 2-pair cabling system into equipment designed for 4-pair cabling (e.g., 100BASE-T), ensure the correct pair assignment is used • Network switches designed for use with 2-pair cabling should not be connected with 4-pair cabling • If mixing 2-pair and 4-pair cabling systems, ensure that the resulting cabling channel meets the requirements of the application.

  27. MICE Concept – Now in TIA-568-C0 • There are three basic types of industrial areas: • Factory floor (MICE 1 or 2) • Work area (MICE 2 or 3) • Automation island (MICE 3) • The areas have mixed environments and are given classifications (subscripts 1, 2 and 3) based on the MICE limits assigned to that level of hazard

  28. “MICE Definitions

  29. MICE Table for Mx & Ix

  30. Example of Environmental Change Along Cable Channel

  31. MICE Environmental Boundaries • Environmental boundaries may occur at the connector locations, enclosures, walls or along any portion of the cabling run Five connection channel with MICE boundaries.

  32. Summary • Standard Allows for 2-pair Cabling Systems • Standard Defines an “Automation Island” • Standard Defines “Automation” Outlets & Cables • Standard States that Category 6 or BetterCabling shall be used for the Automation Islands. • Defines Environmental Concerns in concrete terms with M.I.C.E. Tables (referenced in TIA-568-C0) • POF-Plastic Optical Fiber has been removed for further technical review for later addition to Standard. • The Draft “SP” Ballot is expected to be issued in April for final review in June 2008, possible release of Standard in 2009.

  33. Questions and Discussion

  34. Related Resources • TIA-TR-42.9Industrial Cabling Working Group • ANSI/TIA-1005 Industrial Cabling Standard-Proposed • ANSI/TIA/EIA 568-BCommercial Building Telecommunications Cabling Standard • ANSI/TIA-569-BCommercial Building Standard forPathways & Spaces • ANSI-J-STD-607-A Commercial Building Grounding and Bonding Requirements for Telecommunications • ANSI/TIA/EIA-606-A Administration Standard for Commercial Telecommunications Infrastructure • ISO/IEC 11801Generic Cabling for Customer Premises • ISO/IEC 24702 Information Technology-Industrial Premises • Environmental references: IEC60721-x, IEC60654-x Phone: (919) 549-8411 E-mail Address: info@isa.org