Modern Control SystemEKT 308 Time Response (Contd…) Transient and Steady-State Response Analysis
Performance Measures for step response (contd…) • Delay Time : Time to reach half of the final value for the first time. • Rise Time : Time to rise to the final value. • Underdamped (0% 100%) • Overdamped (10% 90%) • Peak Time : Time to reach the first peak of the overshoot. • Percentage overshoot,
Performance Measures for step response (contd…) Settling time : time required to settle within a certain percentage of the input amplitude (final value). Nominally, is 2% or 5%. For 2%, this occurs when, Two factors affecting transient response: Swiftness of response (rise time and peak time) Closeness to desired response (settling time and overshoot)
Influence of Poles on Transient Response (contd…) • Output consists of • Steady state term • Exponential terms • Damped sinusoidal terms
Influence of Poles on Transient Response (contd…) Impulse response for various root locations