1 / 21

Performance of the PHENIX NCC Prototype

Michael Merkin Skobeltyn Institute of Nuclear Physics Moscow State University. Performance of the PHENIX NCC Prototype. NCC Structure. Electromagnetic part – 12 - 16 layers with 0.7 – 1.2 L rad Hadron part – 6 layers with 17 mm W

binah
Download Presentation

Performance of the PHENIX NCC Prototype

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Michael Merkin Skobeltyn Institute of Nuclear Physics Moscow State University Performance of the PHENIX NCC Prototype

  2. NCC Structure • Electromagnetic part – 12 - 16 layers with 0.7 – 1.2Lrad • Hadron part – 6 layers with 17 mm W • Two stripixel layers preshower and shower MAX detectors CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  3. NCC Prototype. Overview CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  4. NCC Prototype Parts CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  5. NCC Prototype: Sensor CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  6. Sensor Parameters • Thickness - 300 um (525 – plans for real device) • Silicon Resistivity >5 кОм•см • Pads -16, 15 * 15 mm2 each • Sensor size 62 * 62 mm2 • Active area 60 * 60 mm2 • One pad capacitance – 70 pF • Full Depletion Voltage (FDV) – 25 – 45 V CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  7. Sensor Parameters CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  8. Sensor Board CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  9. Front-End Electronics -CR-1.4 • High dynamic range ~2500 MIPs • Noise - 2200 e- + 10 e-/pF • Number of channels per chip/board - 16 CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  10. Front-End Electronics -CR-1.4 • Charge Sensitive preamplifier • Shaper • Analog pipeline • Multiplexer CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  11. Readout electronics, charge sensitive amplifier CR-1 CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  12. NCC requirements* • Energy resolution for one shower at least:σ/E=0.25/E1/2 • Two showers resolution in case:π0→γγ • Electronics dynamicrange >1000 MIP at 1 MIP resolution. *See E.Kistenev presentation CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  13. What we have tested? • Direct connection of several channel from different layers to preamplifier channel (tower) • Three pads have been connected to one channel (will be 6) • Total load capacitance ~200 pF • This is almost limit for CR-1.4 CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  14. Test run at U-70 IHEP, Protvino • 70 GeV protons • 10 GeV positrons CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  15. MIP resolution Amplitude distribution for MIP (μ, p) CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  16. Longitudinal e+ shower profile CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  17. Energy resolution for 10 GeV e+. Full amplitude sum for all layers ~11% CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  18. Picture of Positron Event #17 Run 39 CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  19. CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  20. Picture of Positron Event #29 Run 39 CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin

  21. CALOR06: "Performance of the PHENIX NCC Prototype", Michael Merkin