200 likes | 279 Views
This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims, data and independent validation reports . Blacklight Power’s website is: http :// www.blacklightpower.com. Claims taken from BLP’s website regarding CIHT .
E N D
This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims. Includes claims, data and independent validation reports. Blacklight Power’s website is: http://www.blacklightpower.com Claims taken from BLP’s website regarding CIHT
Regarding CIHT data shown in next two slides: Energy input = 5 mA for 0.4 Seconds at an average of 0.79 Volts. Energy output = 5 mA for 4.1 Seconds at an average of 0.78 Volts Power input = (Duty cycle)*(Volts)*(Current) = (0.4/4.5)*(0.005)*(0.79) = 0.351 mW Power Output = (Duty Cycle)*(Volts)*(Current) = (4.1/4.5)*(0.005)*(0.78) = 3.55 mW Ratio = Output/Input = 3.55/0.351 = 11.2 Gain = (100%)*(Output/Input) = (100%)*(3.55/0.351)= 1120% Claims taken from BLP’s website regarding CIHT Output and input current could be measured using the exact same 1 ohm resistor (volts across resistor would be 0.005 V). Voltage across the cell remains fairly constant at 0.78 to 0.79 Volts. Total error for power measurements can easily be less than 3% with good equipment.
Data taken from BLP’s report on CIHT results. Current Claims taken from BLP’s website regarding CIHT
Data taken from BLP’s report on CIHT results. Voltage Claims taken from BLP’s website regarding CIHT
10 W unit has been tested http://www.blacklightpower.com/faq/ Claims taken from BLP’s website regarding CIHT http://www.blacklightpower.com/technology/ciht-cell/
Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/business/business-summary
Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
Output energy 2000 times the input Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
5000% gain; Output is 50X input here. Energy Gain 10000% 1000% 100% 10% For example, at 100% Energy Gain, output is equal to input. 66 days BLP CIHT results of energy output and gain. source: http://blacklightpower.com/wp-content/uploads/presentations/TechnicalPresentation.pdf
6 teams/individuals from relevent industries wrote validation reports on CIHT Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/technology/validation-reports
Source: http://www.blacklightpower.com/wp-content/uploads/pdf/WeinbergReport.pdf Claims taken from BLP’s website regarding CIHT
5476% gain means that the output is 54 times larger than the input Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/pdf/CopelandReport.pdf
200,000% gain means that the output is 2000 times larger than the input Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/pdf/F500Study.pdf
286% gain means that the output is 2.8 times larger than the input Claims taken from BLP’s website regarding CIHT 242,132% gain means that the output is 2421 times larger than the input
500% gain means that the output is 5 times larger than the input Claims taken from BLP’s website regarding CIHT
735% gain means that the output is 7.3 times larger than the input Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/pdf/RamanujacharyReport.pdf
2400 ratio of output to input ! Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/pdf/GlumacReport.pdf
144028% gain means that the output is 1440 times larger than the input Claims taken from BLP’s website regarding CIHT Source: http://www.blacklightpower.com/wp-content/uploads/pdf/ENSERReport.pdf