190 likes | 384 Views
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies. DS|POWER DS300 series design consept. Reliable and modern Small footprint and less weight More and detailed diadnostic codes Less service and maintenance Completely digital structure
E N D
DS|POWER DS300 seriesNew generation DSP controlledUninterruptible powersupplies
DS|POWER DS300 series design consept • Reliable and modern • Small footprint and less weight • More and detailed diadnostic codes • Less service and maintenance • Completely digital structure • All settings can be done from front panel • Advanced communication • No need adjustment after board replacement • Less control components • Advanced central communication future • Green and efficient • Modular structure • DSP controlled
Why DSP • Fast • Modern • Less control component • Fast mathematical operations • Big memory capacity • Less power consumption • C software support • More and advanced peripherals • Availability (new product)
New features • 3 seperate DSP control • Advanced computer integration • Advanced diagnostic codes • Advanced protection system • Central service code system • Less electronic component • No need adjustment after board replacement • Green(during design and production) • Advanced communication features • Modular structure • Advanced front panel and touch panel option • Output short circuit protection • Regenerative backfeed function • Output current limiting • SMD technology
Protects national electricity system , economic • Input fuse protection ,Electronic input overcurrent protection • Limited input power • Input phase to phase voltage indicator • Input phase to neutral voltage indicator • Input voltage low and high protection • Power factor correction system • Low input current THD • Programmable power walk in time • Programmable start delay • Input RMS current indicator • Input frequency indicator • Seperate PFC DSP • Input on/off switch • Moduler board structure • CAN interface • Memory error control • Advanced diagnostic for input • Regenerative energy backfeed • Selectable input voltage and frequency range
Keep your mains power as spare energy • Split by-pass input • Transferring load to bypass from front panel • Maintenance by-pass switch • Fuse protection on by-pass inputs • By-pass input voltage high protection • By-pass input voltage low protection • By-pass phase-phase voltage indicator • By-pass phase-neutral voltage indicator • By-pass input frequency indicator • By-pass phase balance protection • Optional by-pass isolation transformer • By-pass input switch • By-pass short circuit protection • Output short circuit by-pass isolation • Phase phase output short circuit management • By-pass system diagnostic • Advanced fault and status codes for by-pass
Protects critical load • Output switch • High load crest factor • Output voltage and frequency regulation • Output fuse protection • Output current limiting • Advanced Short circuit protection • Inverter phase to phase voltage indicator • Inverter phase to neutral voltage indicator • Inverter output frequency indicator • Output phase to phase voltage indicator • Output phase to neutral voltage indicator • Output load percentage indicator • Output frequency indicator • Output VA and WATT indicator • Load crest factor indicator • DSP controlled output frequency • Delayed overload protection • Output DC leakage protection • Output alternance loss protection • Output voltage low and high protection • Optional output isolation transformer • Seperate DSP for inverter control • Selectable output voltage and frequnecy range
Maintenance free batteries • Battery fuse protection • 3 level battery level protection • Deep discharge protection • Limited battery charge current • Up to 40 Kva batteries in cabinet • Automatic and manual battery test • Cold start from batteries • Boost charge mode • High current charge capacity • Optional interactive battery switch • Battery voltage indicator • Charge and discharge current indicator • Remaining battery time indicator • Battery temperature compansiation system • Optional battery cabinet for external batteries • Optional continuous battery test system • Selectable battery quantity
Advanced user interface panel • 4x20 character LCD alphanumeric panel • Optional Graphical LCD touch panel • Battery supported RTC clock • Language selection • 5 panel control buttons • Mimic panel with led lamps • Operating hourmeter • Battery, Fan and general maintenance hourmeters • 192 events (7500 alarms) memory (with seconds) • Cabinet temperature indicator • Dialup modem setup from front panel • Relay simulation from front panel • Fault and status codes for troubleshooting • All measured parameters can be monitor • 120 alarms can be monitored at the same time from panel • Backlight brightness adjustment • Central code-password system • 3 Level menu structure • Battery temperature indicator • Optional temperature indicator
Communication • 2 RS232 interface • Multiprotocol support • Control and monitoring from software • 5 NO-NC and function programmable relay outputs • Remote relay simulation • 77777 optional relay contact outputs • Remote clock and date setting • Remote boost charge on/off function • Remote by-pass transfer • Remote sound on/off function • Remote emergency power off input • Remote short battery test • Remote battery discharge test • Remote sleep mode function • Remote monitoring all measured parameters • Remote access security system • Alarm logs (events) loading from RS232 • Calibration over RS232 • Digital automation input
Accessories • Optional RS485 interface • Optional MODBUS interface (TCP/IP or RS485) • Optional SNMP interface • Optional serial port multiplexer • Optional remote monitoring panel • Optional graphical remote monitoring panel • Optional TCP/IP transparent interface • Optional SMS send interface • Optional interactive battery switch • Optional continuous battery test system • Optional synchron unit • Optional battery charger extension • Optional battery backup times
SMD technology Hi-tech test instruments Technologies ONLINE PWM
3 DSP controller Power factor correction system Technologies Low saturation IPM & IGBT power modules
Advanced protection • Overtemperature protection on power modules • Maintenance hourmeters • Saturation protection on power modules • Input power & current limiting protection • Input voltage low protection • Input voltage high protection • Battery charge current limiting • Deep battery discharge protection • Battery low shutdown protection • Battery low warning • Battery voltage high protection • Bypass input voltage low protection • Bypass input voltage high protection • Output current limiting • Output voltage high protection • Output voltage low protection • Advanced output short circuit protection • By-pass short circuit protection • Overload protection • Regenerative backfeed protection • Fuse protection
Easy installation • Simple input ,output and battery connection • Batteries are included in UPS cabinet (up to 40kVA • External batteries are protected in battery cabinet • Selectable frequency (50-60 Hz) • Selectable voltage range (220-230-240 volts) • Free of charge installation support • User manual
Brings many advantages • from 5 to 300 Kva power ranges • Internal moduler structure • Advanced fault codes and diagnostic • Advanced status codes • Programmable warning log filter • Programmable panel backlight • Central code-password system • Econo mode operation • Ergonomic front panel • Input power factor correction • Advanced output short circuit protection • Low weight • Otional earthquake fix system • Small cabinet size • High efficiency • Top cable entry option • Regenerative backfeed for motor loads
Service support • Modular construction • No need adjustment after board replacement • Battery maintenance hourmeter • Fan maintenance hourmeter • General maintenance hourmeter • Economic spare parts • Easy access to all components • Periyodical meintenance • World wide service support • 2 years warranty • 10 years spare parts support • 7-24 technical service support • Central code-password system • Remote data monitoring