1 / 6

HP0-S44 Exam Questions - Affordable HP HP0-S44 Exam Dumps - 100% Passing Guarantee

Download Link : https://officialdumps.com/updated/HP/HP0-S44-exam-dumps/ Get Most Up-to-Date HP HP0-S44 Exam Questions & Answers : Pass Your HP ASE HP0-S44 Exam in First attempt with the Helps of OfficialDumps's Preparation Material. You can Safe your effort, time or money because Officialdumps is providing you Most up-to-date HP ASE HP0-S44 exam Questions & Answers PDF Verified BY HP Certified Professionals. OfficialDumps Also providing you Free 3 Months Updates Related to your [HP0-S44] Exam. You can Get 100% Money Back Guarantee or Special Discount Offer. To Get More info Just Visit Officialdumps.com

Download Presentation

HP0-S44 Exam Questions - Affordable HP HP0-S44 Exam Dumps - 100% Passing Guarantee

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HP HP0-S44 Exam Integrating HP ProLiant Server Solutions Questions & Answers (Free - Demo Version) Thank you for Downloading HP0-S44 exam PDF Demo Buy Full Product Here: https://officialdumps.com/updated/hp/hp0-s44-exam-dumps/

  2. Version: 8.0 Question 1 A customer Is using an HP ProLiant BL460c Gen9 Server with HP FlexFabric 20Gb 2-port 650FLB and an HP c7000 BladeSystem Enclosure with Virtual Connect FlexFabric 20/40 F8 interconnect modules in bays 1 and 2. The integrator is confguring networks and server profles in HP OneView and needs to atach a server blade to a VLAN 51. The integrator will tag proper ports on appropriate switches to take VLAN 51 to the enclosure. Which confguraaon will bring high-availability and fault tolerance against a server port and uplink port failures for VLAN 51? A. Network: Producaonn51 (VLAN ID 51) connected to uplink port Q1.1 on both interconnect modules through single uplink set. Server profle: Connecaon ID 1 and 2 set to Producaonn51 network, port set to Auto B. Network: Producaonn51 (VLAN ID 51) connected to uplink ports Q1.1, Q1.2, Q1.3 and Q1.4 on both modules through a single uplink set. Server profle: Connecaon ID 1 and 2 set to Producaonn5l network, ports set to FiexibleLOM 1 1-a and FlexibleLOM 1:1-c. C. Network: Producaonn51 (VLAN ID 51) connected to uplink ports Q1.1, Q1.2, Q1.3 and Q1.4 on interconnect module 1 through a single uplink set Server profle: Connecaon ID 1 and 2 set to Producaonn51 network and port set to Auto. D. Two networks: Producaonn51nL (VLAN ID 51) connected to uplink ports Q1.1, Q1.2 Q1.3 and Q1.4 on interconnect module 1 through frst uplink set. Producaonn51n_ (VLAN ID 51) connected to uplink ports Q1.1, Q1.2, Q1.3 and Q1.4 on interconnect module 2 through second uplink set. Server profle: Connecaon ID 1 set to Producaonn51 Jn network, port set to FlexibleLOM 1:1-a. Connecaon ID 2 set to Producaonn51n_ network, port set to FlexibleLOM 1:1 -c. Aoswern D Question 2 A customer is implemenang a new rack soluaon in their datacenter. The racks will be supporang a variety of HP ProLiant Gen9 servers in each rack, and the racks will be sharing a common hot aisle due to space limitaaons. The customer is concerned about the amount of heat that will be generated. What should the integrator recommend to the customer for the installaaon of the racks? A. Verify that the ProLiant Gen9 servers have redundant fans installed in them. B. Verify that the backs of the racks are a minimum of 48 inches (121.9 cm) apart to allow for heat release. C. Verity that there are enough cooling vent ales in the shared hot aisle. D. Verify that the rear rack doors are solid in order to defect the heat up through the top of the rack. Aoswern C Question 3

  3. A customer has an HP FlexFabric 650FLB on an HP BL460c Gen9 running VMware ESXi 6.0. The integrator needs to upgrade the driver for this adapter to the latest version released by HP. To avoid a manual download, the integrator plans to use VMware Update Manager (VUM) to download the driver directly. Where should the integrator point VMware Update Manager? A. HP Sofware Depot (htp://sofware.hp.com) B. HP Sofware Delivery _epository (htp //vibsdepot.hp.com) C. HP Live Network (htp://hpln.hp.com) D. HP Driver and Downloads (htp//hp.com/go/support) Aoswern D Question 4 HOTSPOT An administrator needs to add a custom MAC address range for HP OneView. Click the menu opaon to use to confgure the custom range. Aoswern Question 5 A customer with HP ProLiant DL360 Gen9 servers needs to combine Fibre Channel over Ethernet (FCoE) with their LAN trafc over a single 10GbE connecaon. Which FlexFabric adapter meets the customer’s needs? A. HP FlexFabric 20GB 2-port 630FLB Adapter B. HP FlexFabric 10GB 2-port 556FL_-SFP+ Adapter C. HP FlexFabric 20GB 2-port 650FLB Adapter D. HP FlexFabric 650M 2-port Adapter

  4. Aoswern B Question 6 D_AG D_OP Click and drag me HP Power Distribuaon Unit (PDU) model to its matching feature. Aoswern Question 7 D_AG D_OP Click and drag each Power Supply Unit (PSU) to the feature that it supports. Note that PSUs may match more than one feature. Aoswern

  5. For Trying Free HP0-S44 PDF Demo Get Updated HP0-S44 Exam Questions Answers PDF Visit Link Below https://officialdumps.com/updated/HP/HP0-S44-exam-dumps/ Start Your HP0-S44 Preparation

More Related