1 / 31

Contents: Overview of new capabilities of the RESTRAX software

Recent developments of RESTRAX Optimization of neutron optics and virtual triple-axis experiments J an Šaroun 1 , J i ří Kulda 2 , V asyl Ryukhtin 1 1 Nuclear Physics Institute, Řež 2 Institute Laue-Langevin, Grenoble. Contents: Overview of new capabilities of the RESTRAX software

Download Presentation

Contents: Overview of new capabilities of the RESTRAX software

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recent developments of RESTRAXOptimization of neutron optics and virtual triple-axis experimentsJan Šaroun1, Jiří Kulda2, Vasyl Ryukhtin11Nuclear Physics Institute, Řež2Institute Laue-Langevin, Grenoble • Contents: • Overview of new capabilities of the RESTRAX software • Numerical optimizations of TAS parameters • Virtual TAS experiments - simulations with selected sample kernels RESTRAX homepage::http://omega.ujf.cas.cz/restrax/ NMI3 meeting, ISIS, September 26-29, 2005

  2. SIMRES Version for instrument optimizations - more detailed simulation of TAS components - mapping neutron beam in phase-space - tools for numerical optimization

  3. SIMRES - virtual triple axis spectrometer source collimator segments sample crystals detector + setups that can be mapped onto a classical TAS layout (powder and strain diffratometers) multi-purpose components: source:arbitrary energy, spatial and angular distributions via look-up tables crystals:focusing arrays of elastically bent or mosaic crystals (incl. simulated extinction effects, absorption, etc...) collimators:universal components describing: Sollers, curved guides or benders, elliptic or parabolic guides, lobster-eye devices multiplexing:flat-cone multianalyzer and multidetector systems NMI3 meeting, ISIS, September 26-29, 2005

  4. Ray-tracing & numerical optimizations figure of merit, fm(a1, a2, ...): I ... incident intensity DE ... energy spread I / DE, I / DE2 ... inelastic scattering I / Dq, I /Dq2 ... diffraction free parameters, a1, a2, ... an crystal curvature, mosaicity, cutting angle, guide dimensions, curvature, divergence, ... Fixed setup  fast ray-tracing code, 103 -104 counts/sec ray-tracing results are used to find extremum of fm numerically. Speed problem: number of simulations / iteration = 1+2n2 n  4 acceptable (CPU time < 1 hour) NMI3 meeting, ISIS, September 26-29, 2005

  5. Lobster-eye device & focusing monochromator monochromatic beam + spatial focusing monochromatic focusing spatial focusing ? • Simultaneous optimization of the crystal curvatures and guide parameters • mutual correlations • ray-tracing: realistic model of the instrument components NMI3 meeting, ISIS, September 26-29, 2005

  6. Lobster-eye device & focusing monochromator • Lobster-eye device • 20 (hor.) or 30 (ver.) blades • thickness 0.5 mm • m=3 supermirror (concave sides) • elliptic & parabolic profiles • optimization: entry & exit width • TAS - IN14 setup • cold source • straight 58Ni guide, 6x12 cm2 • monochromator: PG 002, doubly focusing, l=4.05 Å • target (sample) area: 3x3 mm2 • optimization: crystal curvatures NMI3 meeting, ISIS, September 26-29, 2005

  7. Focusing on small samples Parabolic guide + perfect focusing of a parallel beam - large reflection angle at the entry NMI3 meeting, ISIS, September 26-29, 2005

  8. Focusing on small samples Elliptic guide - parallel beam does not focus to a point + lamellae are parallel at the entry NMI3 meeting, ISIS, September 26-29, 2005

  9. Lobster-eye device & focusing monochromator Optimization in 2 dimensions x Mapping the parameter space adjustable parameters: horizontal: 1) monochromator: 1/RH 2) guide: exit width vertical: 1) monochromator: 1/RV 2) guide: exit height Number of blades is fixed  adjusting focal distance Resolution 32x32 pixels 1024 simulations NMI3 meeting, ISIS, September 26-29, 2005

  10. Mapping of parameter space Optimization route in 2 dimensions Elliptic blades Intensity/DE Intensity horizontal vertical NMI3 meeting, ISIS, September 26-29, 2005

  11. Mapping of parameter space Optimization route in 2 dimensions Parabolic blades Intensity/DE Intensity horizontal vertical NMI3 meeting, ISIS, September 26-29, 2005

  12. Lobster-eye device & focusing monochromator Optimization in 3 dimensions adjustable parameters: horizontal: 1) monochromator: 1/RH 2) guide: entry width 3) guide: exit width vertical: 1) monochromator: 1/RV 2) guide: entry height 3) guide: exit height Number of blades is fixed  adjusting focal distance and spacing between blades mapping in 3D is not feasible  32768 simulations/map … NMI3 meeting, ISIS, September 26-29, 2005

  13. Lobster-eye device & focusing monochromator Optimization in 3 dimensions Elliptic blades NMI3 meeting, ISIS, September 26-29, 2005

  14. Lobster-eye device & focusing monochromator Optimization in 3 dimensions Parabolic blades NMI3 meeting, ISIS, September 26-29, 2005

  15. Lobster-eye device & focusing monochromator Optimization in 3 dimensions Focusing monochromator only NMI3 meeting, ISIS, September 26-29, 2005

  16. Lobster-eye device & focusing monochromator Total intensity (whole beam) [109/s]: parabolic 1.3 elliptic 1.6 no 3.4 Optimization in 3 dimensions Results NMI3 meeting, ISIS, September 26-29, 2005

  17. RESTRAX Version for TAS resolution simulations and data analysis - simplified TAS setup with faster ray-tracing code - 4D resolution functions + convolution with S(Q,w) - dynamically loaded modules with S(Q,w) model - non-linear data fitting

  18. Sample “exchanger” in RESTRAX TAS ray-tracing, R(Q,w) • dynamically loaded modules, S(Q,w) • Damped harmonic oscillators • Damped harmonic oscillators, free dispersion gradient • Bond charge model (phonons in Si, Ge, ...) • Incommensurate fluctuations (diffuse satellites) • … others defined by users 4D convolution • data simulation • data fitting NMI3 meeting, ISIS, September 26-29, 2005

  19. TAS: conventional arrangement monochromator analyzer sample detector NMI3 meeting, ISIS, September 26-29, 2005

  20. TAS: flat-cone analyzer detector monochromator analyzer sample NMI3 meeting, ISIS, September 26-29, 2005

  21. TAS: flat-cone multianalyzer detector monochromator analyzer sample NMI3 meeting, ISIS, September 26-29, 2005

  22. Sweeping reciprocal space a4 a3 non-linear scans in rec. lattice New flat-cone analyzer for ILL TAS instruments, 32 channels IN20: monochromator Si, ki=3 A-1 NMI3 meeting, ISIS, September 26-29, 2005

  23. Example 1: Incommensurate sattelites E 010 210 M.C. ray-tracing & convolution with S(Q,E) 000 200 010 210 110 raw data Incommensurate sattelites: DE  NMI3 meeting, ISIS, September 26-29, 2005

  24. Example 1: Incommensurate satellites ... and transformed to rec. lattice space NMI3 meeting, ISIS, September 26-29, 2005

  25. Example 1: Incommensurate satellites detail ... NMI3 meeting, ISIS, September 26-29, 2005

  26. Example 2: bond charge model(BCM) Model describing phonons in diamond lattice (Si, Ge, a-Sn, ...) Eigenvalues & eigenvectors are calculated using coulombic potential of bond charges for each of Q,E points representing simulated TAS resolution function W. Weber, Phys. Rev. B 15 (1977) 4789. phonons in Si NMI3 meeting, ISIS, September 26-29, 2005

  27. Phonons in Si E=10 meV E=20 meV NMI3 meeting, ISIS, September 26-29, 2005

  28. Phonons in Si E=30 meV E=40 meV NMI3 meeting, ISIS, September 26-29, 2005

  29. Phonons in Si E=50 meV E=60 meV NMI3 meeting, ISIS, September 26-29, 2005

  30. Phonons in Si convolution with flat-cone resolution simulated by ray-tracing CPU time: 4 hours MC simulation for IN20 kf=3A-1, E=20meV 64 channels, Da4=1.25o 91 steps, Da3=0.75o E=20 meV NMI3 meeting, ISIS, September 26-29, 2005

  31. Summary • Numerical optimizations • using ray-tracing simulations in numerical optimization is feasible • multiple correlated TAS parameters can be optimized with respect to different figures of merit • Lobster-eye guides • high flux at small samples, leaves space for sample environment • vertical and horizontal focusing can be splitted in 2 guide sections • alternative to focusing monochromators at quasiparallel beams • Dynamically loaded S(Q,w) modules • data simulations and fitting with various sample kernels • extensions provided by users RESTRAX homepage::http://omega.ujf.cas.cz/restrax/ NMI3 meeting, ISIS, September 26-29, 2005