1 / 11

Common Water Treatment Problems

Common Water Treatment Problems. Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related Iron. Stains Red Manganese -Similar concerns as Iron, but usually stains Black.

blaze
Download Presentation

Common Water Treatment Problems

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Common Water Treatment Problems Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related Iron. Stains Red Manganese -Similar concerns as Iron, but usually stains Black. Total Dissolved Solids (TDS) -Indicates the total amount of dissolved minerals in the water. This would include the Hardness, Iron and Sodium, but not Bacteria or H2S. Bacteria -Microorganisms that multiply and feed from the elements in water. Can be very harmful, such as Fecal Coliform, or only an aesthetic concern like Iron Bacteria. Arsenic -Now considered one of the poisonous elements in water. Must remove at very low amounts (0.01 mg/l). Tannins -Decaying vegetation in water. Gives water a tea colour. Hydrogen Sulfide (H2S) -In a gas form, and gives a Rotten Egg smell to the water. Will normally dissipate when exposed to atmosphere, but can be associated to Bacteria concerns, and in high enough levels, could be harmful.

  2. Water Softener Tannin/Colour Remover Iron Filter Control Valve Control Valve Direction Of Flow Brine Line Resin Tank Mineral Tank Regenerate Line Brine Tank Drain Line Pot. Perm. Feeder Air Gapped Drain

  3. Reverse Osmosis Systems-When and Where Does It Fit? • An RO reduces TDS. The conductivity of the water is effected by the TDS in the water. Generally speaking, Low TDS=Low Minerals and Salts in water. • RO systems are considered a purifier, due to the reduction of the TDS, thus bringing water closer to it’s original form, without the elements found in TDS. • Use RO systems when water has taste or smell concerns. Use RO water for an health related concern. • An RO should always be the last product in the treatment chain, except if an UV is used for post RO protection. • An RO should only be used, whenever possible, on clear Microbiological safe water. Giardia & Cryptosporidium Cysts 99.99% Sodium 95 - 99% Nitrate 90 - 99% Arsenic +5 95 -99 % Lead 95 - 99 % Copper 95 - 99 %

  4. 5 Stage Reverse Osmosis System

  5. Ultraviolet Light (UV) Disinfection Systems • For the disinfection or sterilization of microorganisms. • Specifically, UV affects the DNA structure of a Bacteria cell. The sterilized Bacteria can not reproduce. Now considered harmless. • The flow through a UV is critical for effective dosage. Flow Control • The water quality entering the UV MUST be clear, or low in Turbidity. • A sediment cartridge rated @ 5 Micron, minimum, should always be used to pre treat the water, along with appropriate Filtration. • A UV is always installed after pretreatment • Often used at the point of entry (POE), a UV is more effective installed as close to the point of use (POU) as possible.

  6. UV System • Flow GPM must be regulated to rating of UV • Incoming water must be clear in colour • Maintain constant power to unit • Use surge protectors

  7. Chemical Feed Pump Systems • Two types are most common: • Solenoid/Diaphragm ( Pulsafeeder, LMI,) • Peristaltic ( Stenner ) • Both styles can be 115V or 230V. • Both can be on/off or remote controlled. • Both require attention to chemicals used, and sizing requirements. • Sizing a Pump: • Well Pump GPM x Required Dosage PPM x 1440 / Solution Strength PPM = Feed Rate in GPD • Dosage Calculations: • 1 PPM Bleach =1 PPM Iron, 3 PPM Bleach = 1 PPM H2S, • * Plus add required residual to dosage. ( 0.5 to 1 PPM) • Solution Strength: • 5% Bleach – 52,500PPM. 12.5% Bleach – 125,000PPM. • Choose a pump’s max. output that is twice the GPD required. • Rule of thumb for contact time is 20 Minutes. Actual pH and temp. of water does have an impact on contact time required.

  8. Non-Chlorinated Outside Service Line. If Required. Optional Chemical Pump Flow Meter To Service Line Contact Tank Pressure Tank Check Valve Multi-Media Filter Carbon Filter Injection Point Chemical Injection Pump, and Solution Tank. Standard Chlorine Pump System C/W Non-Chlorinated Outside Service Well Pump

  9. To Drinking Water Faucet Usual Sequence or Placement of Common Filtration Products RO System 5 Micron Sediment Water Softener Carbon Filter Multi-Media Filter Iron Filter UV Pressure Tank Pot.Perm. Feeder Brine Tank Well Pump

More Related