1 / 5

500cm

SEGMENTATION OF THE READOUT PLANE. 18 trapezoidal sectors. 83cm. 248cm. 88us. 500cm. Inner chamber 5504 pads. Outer chamber 10332. TPC DETECTOR. LATERAL VIEW OF THE TPC. 1MIP = 4.8 fC = 3 x10 4 e Dynamic : 30 MIP S / N = 30:1. SIDE VIEW. FRONT VIEW. 36 trapezoidal sectors.

bobby
Download Presentation

500cm

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SEGMENTATION OF THE READOUT PLANE 18 trapezoidal sectors 83cm 248cm 88us 500cm Inner chamber 5504 pads Outer chamber 10332 TPC DETECTOR LATERAL VIEW OF THE TPC 1MIP = 4.8 fC = 3 x104 e Dynamic : 30 MIP S / N = 30:1 Luciano Musa - CERN

  2. SIDE VIEW FRONT VIEW 36 trapezoidal sectors Capton Cable C6 : 20 FECs Outer chamber C5 : 20 FECs C4 : 20 FECs FEC 190mm C3 : 18 FECs C2 : 25 FECs 140mm Inner chamber C1 : 18 FECs 128 channels Front End Card (FEC) TPC FEE: MOUNTING Luciano Musa - CERN

  3. FEC 128 ch FEC 128 ch FEC 128 ch FEC 128 ch FEC COOLING CONF. & R/O MON. & CTRL TRIGGER INT (TTC-RX) FEE ARCHITECTURE GLOBAL ARCHITECTURE Each TPC Sector is served by 6 Readout Subsystems 1 LOW VOLTAGE POWER SUPPLY UX CRX 2 CONFIG. & READOUT NETWORK (100 MB / s) DATA PROC. DATA MEMORY DAQ INT (DDL-SIU) DCS NETWORK DCS INT (PROFIB, ETHER, ...) 25 BOARD CONTROLLER RCU Overall TPC: 4356 Front End Card 216 Readout Control Unit Luciano Musa - CERN

  4. FEC COOLING FRONT-END CARD 128-CHANNEL FRONT-END CARD LV SUPPLY readout bus connectors control bus connector power supply connector cooling pipe voltage regulators GTL transceivers (back side) current monitoring & supervision ALTROs Shaping Amplifiers Kapton cables to TPC Luciano Musa - CERN

  5. FRONT_END CARD FEE PARAMETERS TO BE MONITORED AND/OR CONTROLLED (PRELIMINARY !) • Front End Card (FEC) • Temperature: 1 value (10 bits) / FEC R • Volt. Reg. State (on/off): 8 values (8 bits) / FEC R/W • Power Switches (on/off): 2 values (2 bits) / FEC R/W • Analogue Voltage: 1 value (10 bits) / FEC R • Digital Voltage: 1 value (10 bits) / FEC R • Status / Error Register: 1 value (64 bits) / FEC R/W • Readout Control Unit (RCU • Volt. Reg. State (on/off): 4 values (8 bits) / FEC R/W • Power Switches (on/off): 1 values (2 bits) / FEC R/W • Digital Voltages: 2 value (20 bits) / FEC R • Status / Error Register: 1 value (64 bits) / FEC R/W • Events that could damage the FEE components are hardware protected. • The FEE cooling and LV POWER SUPPLY have their independent set of sensors. Luciano Musa - CERN

More Related