1 / 16

Composed by Dr. Gary F. Turnier

Composed by Dr. Gary F. Turnier. Implant placement. Dr.Gary F. Turnier. Premedication with 1gm Azithromycin 1 hour before tx Ibuprofin 600mg 1 tab 1 hour before tx. Local anesthesia:4 carp. Articaine HCL 4% with epinephrine 1:100,000 Informed consent given

Download Presentation

Composed by Dr. Gary F. Turnier

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Composed by Dr. Gary F. Turnier Implant placement Dr.Gary F. Turnier

  2. Premedication with 1gm Azithromycin 1 hour before tx Ibuprofin 600mg 1 tab 1 hour before tx Local anesthesia:4 carp. Articaine HCL 4% with epinephrine 1:100,000 Informed consent given Surgical procedure performed by Dr. Gary F.Turnier Dr. Gary F. Turnier

  3. Maxillary soft tissue considerations: Since interdental papillae –saving incision was not needed , sulcular incision performed midcrestal mesial of #15-distal of #13 Dr. Gary F. Turnier

  4. Dr. Gary F. Turnier

  5. 9.94 MM M-D

  6. Drilling sequence A-LENDERMAN’SDRILL 9MM B.2.3MM PILOT DRILL 10MM C.2.8MM OSTEOTOMY DRILL 10MM D.3.4MM OSTEOTOMY DRILL 10M-FINAL DRILL FOR PLA CING A 4.7X11.5MM IMPLANT

  7. ZIMMER GUIDE PIN Dr. Gary F. Turnier

  8. Used Nobel Biocare osteotomes Bone spreading techniques 3.4mm osteotomy drill was used to a depth of 10mm then Dr. Kale proceeded to use the osteomes to a depth of 11mm. Using the engine to place the implant , we achieved a torque of 55ncm and at this point we had to use the Gemlock Retaining Square ratchet to hand torque. As a result of the bone spreading with the Nobel Biocare Osteotomes. The hand torque ratchet was extremely difficult due to the tightness between implant and bone contact. It felt like D1 bone. We might of achieved a torque of >70ncm as a result of using the osteotomes. However, it was so tight that in hindsight, we could of gone to the 3.7mm osteotomy drill and proceeded with implant placement without sacrificing buccal bone. Dr. Gary F. Turnier

  9. Dr. Gary F. Turnier Nobel Biocare Osteotomes measured with perio probe to confirm depth of 11mm

  10. Dr. Gary F. Turnier

  11. 4.5mm diameter platform diameter Dr. Gary F. Turnier

  12. ZimmerTapered screw vent implants have 1.0mm machined milled platform and 1.5mm textured surface 4.5mmDiameter platform 4.7mm Diameter tapered screw vent body 1.0mm 1.5mm 2.5mm length from first thread to the coronal aspect Dr. Gary F. Turnier

  13. sinus 9.0mm implant tapered screw-vent MTX surface 2.5mm THCW5/5 healing collar for internal hex 4.5mm diameter platform Dr. Gary F. Turnier

  14. Dr. Gary F. Turnier

  15. Dr. Gary F. Turnier

  16. THE END .

More Related