1 / 21

Liquid metal flow under inhomogeneous magnetic field

Liquid metal flow under inhomogeneous magnetic field. O. Andreev, E. Votyakov, A. Thess, Y. Kolesnikov. TU Ilmenau, Germany. Electromagnetic Brake (EMBR). magnet system. Main goal. Avoid flow instability. 1. Smooth mean velocity profile. Avoid sources of instability.

Download Presentation

Liquid metal flow under inhomogeneous magnetic field

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Liquid metal flow under inhomogeneous magnetic field O. Andreev, E. Votyakov,A. Thess, Y. Kolesnikov TU Ilmenau, Germany

  2. ElectromagneticBrake (EMBR) magnet system

  3. Main goal Avoid flow instability 1. Smooth meanvelocity profile Avoid sources of instability 2. Brake generated and introduced velocity fluctuations

  4. N S top view ly side view lx Experimental setup Bz magnetic field Vives probe Plexiglas cover blocks potential probe lx y N In- Ga -Sn S honeycomb inlet contractor permanent magnet outlet diffuser 30 mm

  5. General view of test-section Coordinate system Permanent magnet Channel: S = 210 cm L = 90 cm Liquid metal: GaInSn

  6. B z B max B × F ~ j B ´ - Ñ j = s z V B j / x y z B max 0,5 M-shape velocity profile 0,25 X, mm - 105 - 75 - 45 - 15 15 45 75 105 Y, mm 50 Flow 25 0 0,25 0,5 - 25 B - 50

  7. Governing parameters Reynolds number: Re=U0H/ Re<15000 Hartmann number: Ha=B0H(/)1/2 Ha=400 MHD interaction parameter: N=Ha2/Re N>40 U0 < 35cm/s, B0=0.5T, H=2cm

  8. (a) 3,5 0 3 Flow 2,5 2 x= - 106 mm - 29 20 1 0,5 0 - 0,5 - 50 - 40 - 30 - 20 - 10 0 10 20 30 40 50 Y, mm E y E 0 Streamwise velocity in the middle plane of channel potential velocimetry Re 4000

  9. flow flow Streamwise velocity in the middle plane of channel ultrasound velocimetry Re 4000 magnet

  10. Re =4000 I. turbulence suppression region II. vortical region III. wall jet region % u´/U0 15 12.5 10 7.5 on the axes near walls 5.0 2.5 0 -5 -2.5 0 2.5 5 7.5 10 Decay of velocity fluctuations under the external magnetic field B Magnet Flow

  11. Accuracy ofpotential velocimetryin the region ofinhomogeneousmagnetic fieldis ?!

  12. Principles of potential velocimetry from Ohm’s law y streamwise velocity x physical ERROR of the potential velocimetry measurable values

  13. positivevalues of el.current negative values of el.current positivevalues of el.current directnumericalsimulationbyE. Votyakov,E. Zienike electrical current in the middle plane spanwise Jy electricalcurrent overestimatedvalues of velocity overestimatedvalues of velocity underestimatedvalues

  14. flow flow rate through the channel integral estimation oferror voltmeter potential difference between the side walls movable electrodes onthe side walls

  15. flow 3.5 Re= 3 2716 4014 2.5 overestimatedvalues of flow rate 5312 potentialdifference 6611 2 7909 overestimatedvalues of flow rate 9207 1.5 underestimatedvalues 10505 11804 1 13102 Magnetic field 0.5 flow rate 0 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 x/H, dimensionless streamwise coordinate

  16. Re 4000 flow Comparison of ultrasound and potential velocimetry X/H=0 streamwisevelocity DOP2000 potentialprobe

  17. flow Vivesprobe DOP2000 Comparison of ultrasound and potential velocimetry Re 4000 X/H=-3 streamwisevelocity potentialprobe

  18. flow Vivesprobe DOP2000 Comparison of ultrasound and potential velocimetry Re 4000 X/H=2 streamwisevelocity potentialprobe

  19. flow Vivesprobe DOP2000 potentialprobe Comparison of ultrasound and potential velocimetry Re 4000 X/H=6 streamwisevelocity

  20. flow Vivesprobe DOP2000 Comparison of ultrasound and potential velocimetry Re 4000 X/H=8 streamwisevelocity

  21. Summary remarks • The laboratory flow was investigated in the following range of the governing parameters: Ha = 400, Re<15000, N>10. • Potential probe qualitatively reproduces velocity field within the region of two magnet gaps in streamwise direction. • Vives probe is strongly influenced by the external electric potential and could be applied on the distance which exceeds 5-6 gaps of magnet.