390 likes | 480 Views
Copy/paste from Seville, with some news Status of Mg(n, g ) with C 6 D 6 in nTOF-Ph1 CERN, 12.04.2011 Cristian Massimi. Intoduction. Mg data in literature. Activation (thermal) Walkiewicz and Ranan Phys. Rev. C 45, 4 (1992). Activation (MACS) Mohr et. al., Phys. Rev. C 58, 2 (1998).
E N D
Copy/paste from Seville, with some news Status of Mg(n,g) with C6D6 in nTOF-Ph1 CERN, 12.04.2011 Cristian Massimi
Intoduction Mg data in literature Activation (thermal) Walkiewicz and Ranan Phys. Rev. C 45, 4 (1992) Activation (MACS) Mohr et. al., Phys. Rev. C 58, 2 (1998) • Charged particle reaction • Denhard et al., Phys. Rev. 160, 964 (1967) • Hardy et al., Academic • Photo-neutron (g,n) • Baglan et al. Phys. Rev. C 3, 672 (1971) • Same experiment, Phys. Rev. Lett. 24, 319 (1970) • Neutron induced reactions A) Transmission • Singh et al. Phys. Rev. C 10 2150 (1976) • Newson, Block et al., Ann. Phys.8, 211 (1959) B) Capture • Macklin et al., Rev. Mod. Phys. 37, 166 (1965) • Bergquist et al., Phys Rev. 158, 1049 () • Block et al., RPI technical report • Nystrom et al., Phys. Scr. 4, 95 (1971) Transmission + Capture + elastic: Weigmann, Macklin and Harvey, Phys. Rev. C 14, 4 (1976) + D.J. Horen, J.A. Harvey, N.W. Hill, Phys. Rev. C 3, 1168 (1976) + Koehler, Phys. Rev. C 66, 055805 (2002) ORELA
Introduction Mg data in literature • Nutron induced reactions The available experimental data for 24,25,26Mg are essentially based on a time-of-flight measurement performed at ORELA: • very high-resolution transmission measurement (200-m flight path, metallic natMg sample, plastic scintillator) • high-resolution capture measurement (40-m flight path, 97.9% 25Mg enriched sample, fluorocarbon scintillators) • Elastic neutron scattering at 200-m flight path (angular momentum) Capture data on 24,26Mg from ORELA are missing
Introduction • Evaluation does not consider: • - the photoneutron cross-section measurement 26Mg(,n)25Mg by Berman et al.(PRL 1969), J • - a recent work by P. E. Koehler (PRC, 2002) R-matrix analysis of existing measurements • News: the mass of the natMg sample was wrong by > 10% Mg data evaluation • Existing evaluations are based on JENDL3.3 (by T. Asami) • JENDL 4 (2010) isnot updated • Resonance parameters in resolve resonance region are taken from BNL (Mughabghab) and negative resonances were added to reproduce the measured thermal cross-section
Experiment Mg samples 2.2-cm in diameter. Oxide sample sealed in an aluminum canning. Al canning is 0.35 g (1.127E-03 at/b). First TOF measurement on an enriched 26Mg sample News: it can not be used for RSA, anyway it adds important information concerning resonance identification News: 25Mg sample shows an areal density 30%lower than decleared !!!
Data analysis • Detector energy calibration: g-ray sources • Weighting Function (F. Gunsing) News: threshold = 200KeV • Normalization: C6D6 and SiMon calibrated to 3% accuracy by saturating the 4.9-eV resonance in Gold with a 0.25-mm thick sample News: added g-ray attenuation in WF (for Au) • Time-energy calibration: • TOF = Tn - T0 • Where T0 = Tγ – L / C • L = 185.07 m, from resonances in Au • News: a constant offset of 14 ns has been observed respect to ORELA data
Resonance shape analysis News: we assign this resonance to 26Mg, it was thought to belong to 24Mg n + 26Mg ORELA n_TOF When data are not available, EVALUATION uses average reaction width Gg = 3 eV This resonance was doubtful, thought to belong to 24Mg.
Resonance shape analysis News: we confirm that these resonances belong to 26Mg n + 26Mg n_TOF n_TOF Huge discrepancy between Weigmann [TOF at ORELA] and Mohr [ACTIVATION]. “Resonance strength should be a factor 2.8 lower than the result from ORELA”.
26Mg MACS n + 26Mg MACS at 30 keV from present measurement: 0.106 ± 0.01 mb NEWS: Probably nonsense. No way to check for the areal density Negative resonance changed to reproduce the thermal neutron cross section New value for the Radius
Resonance shape analysis n + 24Mg Evaluation ≈ ORELA n_TOF ORELA
Resonance shape analysis n + 24Mg Evaluation ≈ ORELA n_TOF ORELA
Resonance shape analysis n + 24Mg
Resonance shape analysis n + 24Mg
Resonance shape analysis n + 24Mg
Resonance shape analysis n + 24Mg
Resonance shape analysis n + 24Mg
24Mg MACS n + 24Mg News: from present measurement: MACS at 30 keV 3.7 ± 0.2 mb MACS at 90 keV 2.4 ± 0.2 mb Preliminary calculations (A. Mengoni): Direct capture component to the MACS < 1 mb Negative resonance changed to reproduce the thermal neutron cross section New value for the Radius
Problem with 25Mg n + 25Mg, the large s-wave resonance at 20 keV In capture, when Gn >> Gg the RSA is sensitive to ngGg News: from natMg sample, 25Mg enrichment 95% 70% Uncertainty 10 - 15%
Resonance shape analysis n + 25Mg
Resonance shape analysis n + 25Mg
Resonance shape analysis n + 25Mg
Resonance shape analysis n + 25Mg
Resonance shape analysis n + 25Mg
Resonance shape analysis n + 25Mg
Resonance shape analysis n + 25Mg
Resonance shape analysis n + 25Mg
25Mg MACS n + 25Mg News: from present measurement: MACS at 30 keV 4.2 ± 0.2 ± ? mb MACS at 90 keV 1.5 ± 0.2 ± ? mb Preliminary calculations (A. Mengoni): Direct capture component to the MACS < 1 mb Negative resonance changed to reproduce the thermal neutron cross section New value for the Radius
Results • Resonance parameters of the 24Mg(n,) and 26(?)Mg(n,) reaction cross-sections have been determined. • Sizable differences have been found respect to the existing evaluation, JENDL4 (2010). • Smaller differences respect to ORELA data (in average 10%). • Direct capture component is an important mechanism, upper limit: 1 mb to the MACS.
Conclusions • The present (n,) measurements improve the cross section data on 24,26(?)Mg isotopes. New value for the MACS are available. • From this analysis we find that the MACS of 25Mg isotope is lower than reported previously because of a problem with the sample. • The contribution of the direct capture mechanism should be investigated experimentally. • Is 26Mg sample thickness correct? • Is it worth to repeat the measurement on 25,26Mg using a metallic sample
Cristian Massimi Dipartimento di Fisica massimi@bo.infn.it www.unibo.it
Experiment Mg samples 2.2-cm in diameter. Oxide sample sealed in an aluminum canning. Mg isotopes Gold Lead Carbon same diameter
WF Weigthing Functions
Problem with 25Mg n + 25Mg