An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SGS 6 - 15 6th HFCV-SGS Meeting Research Activities of HFCV in Korea May 26 ~ 29, 2009 Ministry of Land, Transport and Maritime Affairs, Korea Transportation Safety Authority (Korea Automobile Testing and Research Institute) In corporation with Hyundai Motor Company

  2. Contents Hydrogen ? • Hydrogen Leakage Test • Driving Mode • Stop Mode • Rear Impact Test • Possibility of Hydrogen Discharge • Storage Verification Test • Summaries Hydrogen ?

  3. Air 10m/s 6M 12M 14.1M Hydrogen Leakage Test : Driving Mode • Goal : Verification of single failure conditions • Conditions • Driving speed: 36 km/h • Open space : 14.1 m x 12 m x 6 m • Leaking point: fitting area between high pressure fuel line and refilling line in the rear of vehicle • Leaking flow : 131 NL per minute • Simulation Model • Tool : STAR-CCM+ • Mesh : polyhedral mesh (1,060,000) • Turbulence model : κ-ε model • Steady-state analysis

  4. A A B H2 Vol % 0.0 4.0 % AIR 10 m/s Driving Mode Simulation Results • Results • Hydrogen was diffused by outside air flow • Hydrogen concentration level over 4 % by volume in air is localized near leaking area Vehicle underbody view Section A-A Detail of B Air flow outside vehicle Velocity profile near storages area

  5. 34 33 27 26 29 25 32 24 22 23 28 30 31 20 21 18 19 Positions of sensors 1 3 10 6 11 5 9 4 7 2 Stop Mode Test Conditions (1) • Positions of hydrogen sensor Positions of sensors (under flower) • Expected hydrogen leaking points : • High(5)/low(4) pressure lines and engine room(2)

  6. Stop Mode : Test Conditions (2) Valve Valve Regulator Storage(35MPa) leakage Valve Regulator Valve Storage Hydrogen leakage device Single failure conditions test • Conditions of hydrogen leaking flow • 10 NL per minute : low leaking mode • 40 NL per minute : max. leaking mode before activation of excess flow valve • 131 NL per minute : leaking limit in FMVSS 301

  7. Hydrogen Leakage Test Results • Driving Mode • Diffused rapidly due to wind flowing outside vehicle • Sensors did not detect leaking hydrogen except sensors near leaking area • Stop Mode • Leaking hydrogen may enter into vehicle through holes on the bottom if hydrogen leaks underneath the body • Leakinghydrogen may enter into vehicle through running HFCV system if hydrogen leaks in engine room Preventive measure needed • Hydrogen continued to leak for about 10 seconds before shutdown after 2 % hydrogen was detected  There were some area where hydrogen up to 4 % was detected before shutdown. But concentration dropped below 4 % within one minute • Conclusions • Optimization of number of sensors and their locations is needed for effective detection depending on vehicle structure 2-3 sensors out of 5 sensors may be removed in case of HFCV SUV • Interior sensors should be considered for detecting hydrogen entering from outside

  8. Goal : Verification of fuel system integrity • Test Vehicle • Mock up fuel cell vehicle • Test Conditions • KMVSS article 91(FMVSS 305) : 48 km/h rear impact test • Filled with helium 90 % of normal working pressure • During the crash, opened storage valve (severe condition) • After crash test, evaluate hydrogen discharge BIW of HFCV SUV Mounted storages Sample vehicle Rear Impact Test (Fuel System Integrity)

  9. Rear Impact Test Results : Hydrogen Discharge • After impact, no hydrogen discharge • High pressure sensor : 30 MPa • Low pressure sensor: 1 MPa

  10. Rear Impact Test Results : Verification Test of Storage • Verification Test of Storage • Storage was damaged due to deformation of suspension during impact • Verification test of damaged storage  No noticeable degradation Damaged carbon fiber layers of storage Under body rear suspension Verification test of damaged storage  Passed after 11,250 cycling tests at 103 MPa

  11. Summaries • Hydrogen Leakage Test (Single Failure Conditions) • Optimization of number of sensors and their locations is needed for effective detection depending on vehicle structure • In this particular model of HFCV SUV, some sensors are redundant • Interior sensors should be considered for detecting hydrogen entering from outside • Rear Impact Test (Fuel System Integrity) • Exterior of storage was damaged due to deformation of suspension during impact No noticeable strength degradationafter endurance test • No malfunction in other storage components • Impact absorbing structure should be devised

  12. Thank you very much for your attention ! Acknowledgement This research was supported by a grant (07-Transport System-Furture-02) from Transportation System Innovation Program funded by MLTM