50 likes | 407 Views
CRISP AMI . Objective To determine if routine intra-aortic balloon pump (IABP) placement prior to reperfusion in patients with anterior STEMI without shock reduces infarct size Study Design Randomized, open-label, multicenter, controlled trial
E N D
CRISP AMI Objective • To determine if routine intra-aortic balloon pump (IABP) placement prior to reperfusion in patients with anterior STEMI without shock reduces infarct size Study Design • Randomized, open-label, multicenter, controlled trial • 337 patients randomized to either IABP prior to PCI (n=161) or standard PCI with “bailout” IABP (n=176) Primary Endpoint • Infarct size as measured by cardiac MRI Secondary Endpoints • All-cause death at 6 months • Vascular complications and major bleeding at 30 days
CRISP AMI Results • Mean infarct size was not statistically significantly different between the patients in the IABP plus PCI group and those in the standard PCI group (42.1% vs 37.5%, respectively; p=0.06) Primary Endpoint
CRISP AMI Conclusions • Compared with PCI alone, IABP plus primary PCI did not result in reduced infarct size among patients with acute anterior STEMI without shock • All-cause mortality at 6 months did not differ significantly between the two groups