380 likes | 638 Views
RS PRO 500 RS PRO 1000 RS PRO SYSTEM - our high-frequency technology as a consequent further enhancement for professional requirements. RS PRO SYSTEM. Light when needed, decentralised light monitoring State-of-the art HF-technology highest possible energy efficiency
E N D
RS PRO 500 RS PRO 1000 RS PRO SYSTEM - our high-frequency technology as a consequent further enhancement for professional requirements.
RS PRO SYSTEM Light when needed, decentralised light monitoring State-of-the art HF-technology highest possible energy efficiency Convenience and security high degree of installation flexability Modular add-on of system features and functions
HF-Technology is more superior than PIR-Technology in the indoor invironment Extremely better radial detection (radial detection is the norm for ceiling mount fixtures!) Extremely higher monitoring range Temperature independent (heater, air cons, ovens, refridgerators etc.) No visible exterior sensor lens
Comparison PIR - HF Sensors normal PIR Sensor 130° High-Tech HF Sensor approx .5m radial movement (sensitivity) approx.1,5 - 2,5m radial movement Reach This leads to a large reach improvement and more comfortable switching behavior in daily use.
HF- Detection View Detection 360° with 160° opening aperature 5,8 GHz, approx. 1mW high-frequency output Max. detection area approx. 50qm
Die RS PRO Sensor fixtures operate decentral or in network groups.
Fixture groups of Master-Master or Master-Slave units can be set up.
Fixture groups of Master-Master oder Master-Slave units can be set up.
Fixture groups ofMaster-Master or Master-Slave units can be set up.
Fixture groups of Master-Master or Master-Slave units can be set up.
Fixture groups of Master-Master or Master-Slave units can be set up.
Fixture groups of Master-Master or Master-Slave units can be set up.
E x i t Ideal locations: Stairwells Aisles Basements Storage rooms Garages / Underground car parks Toilettes/lavatories Maintenence rooms Washrooms
RS PRO Versions Hard wired Wireless channeling - 2x 13W RS PRO 500 2x 18W RS PRO 1000 RS PRO 1000
RS PRO 500 2x13W b3 Hard wirefixture grouping (max. 10 x RS PRO 500 Slave per Master).
Hard wire fixture grouping (max. 5 x RS PRO 1000 Slave per Master) or via wireless modules (unlimited within spec´d detection range). RS PRO 1000 2x18W Wireless module - bi-directional - 32 channels - 868 MHz - ideal up to 30m distance fromfix- ture. b6
RS PRO Modular System RS PRO 500 RS PRO 1000 - W optional optional LED Module Bat. optional LED Module optional optional 2x13W 1 EB 2x18W 2 EB Slave Version 2x18W 2 EB 2x13W 1 EB Sensor Version 280mm Acryl Diameter/ Material shade 310mm Acryl or glass
RS PRO 1000 L‘ für wireless connection or external consumer Wireless module (optional) Aluminum Chassis Plastic cassette (protection class 2) LED Module (optional) Light dim- ming resistor 2x18W energy saving bulbs with 2 independent EB´s High--frequency sensor 5,8 GHz
RS PRO 500 Aluminum Chassis L‘ for wireles connection or external consumer Plastic cassette (Protection class 2) LED Moduel (optional) Light dim- ming resistor 2x13W energy saving bulbs with 1independent EB High-frequency sensor 5,8 GHz
RS PRO 500/1000 Twilight setting (darkl, 100, 150, 300 Lux, light and Teach mode of current ambient lux after 10 seconds) Time setting 1min - 20min, incl. install mode (only 3 sec., 10min after last movement unit switches to normal mode of 1 minute) Light dim- ming resistor HF Sensor Reduction of reach in 4 directions using plug on shourds (metal) Reach setting (sensitivity) should be set during install mode
Module LED Module LED Module/Bat. Wireless module/ RS PRO1000
LED Module 25 white LED´s approx. 2,5W Test button Red LED indicating battery charging (only battery version) with and without battery pack Independent light dimming resistor Independent lux setting knob; no orientation light if knob turned to right stop
An aisle with basic illumination via LED module.
The LED module with battery offers 3-8 hours of basis security illumination depedent on charging status of battery. Ideal also in private households.
Wireless Module with Master fixtures K2 32 channels possible K2 K2 K1 K1 K1 K1 K1 Receiving signal area
Wireless Module with Master fixtures K2 32 channels possible K2 K2 K1 K1 K1 K1 K1 Receiving signal area
Wireless Module with Master fixtures K2 32 channels possible K2 K2 K1 K1 K1 K1 K1 The logic: „The last person leaving turns off the lights“
Wireless Module with Master fixtures K2 32 channels possible K2 K2 K1 K1 K1 K1 K1 The logic: „The last person leaving turns off the lights“
Wireless Module with Slave fixtures K1 32 channels possible S K1 K1 K1 K1 K1 S S M M M Receiving signal area
Wireless Module with Slave fixtures K1 32 channels possible S K1 K1 K1 K1 K1 X S S M M M Receiving signal area
Wireless Modue with Slave fixture K1 32 channels possible S K1 K1 K1 K1 K1 S M M S M Receiving signal area
Wireless Module Setting up individual networks with sensIQ is also possible
Energy Saving Convenience Security Flexability
Security Economy Convenience Flexibility