1 / 24

MuCap

MuCap. High Precision Measurement of Muon Capture on the Proton. Tom Banks Weak Interactions Group UC Berkeley Physics LBL NSD Monday Morning Meeting 30 August 2004. Purpose of the Experiment. Our goal is to measure the rate Λ s for muon capture on the proton.

cabner
Download Presentation

MuCap

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MuCap High Precision Measurement of Muon Capture on the Proton Tom Banks Weak Interactions Group UC Berkeley Physics LBL NSD Monday Morning Meeting 30 August 2004

  2. Purpose of the Experiment Our goal is to measure the rate Λs for muon capture on the proton to 1% precision. Muon capture is a semileptonic weak interaction process, and in our experiment capture occurs predominantly from the hyperfine singlet atomic bound state.

  3. Experimental Technique For μ– in hydrogen gas, muon capture competes with muon decay: However, the muon capture channel is not available for μ+, so positive muons can only disappear via decay:

  4. Experimental Technique MuCap only observes decay electrons. Therefore, due to muon capture, we see a small downward deflection of the μ– decay curve from the μ+ “vacuum” decay curve (i.e. the μ– appears to have a shorter lifetime): log(counts) μ+ μ – “Lifetime” or “Disappearance” Method time The capture rate is easily calculated from the measured muon lifetimes:

  5. At the elementary particle level, the weak interaction is fundamentally V–A. d νμ gVud g W u μ– Standard Model Theory

  6. Standard Model Theory However, muon capture involves nucleons rather than isolated quarks. The strongly-interacting substructure of the proton and neutron complicates the weak interaction physics. These complicating effects are encapsulated in the nucleonic charged-current’s four “induced form factors”: n νμ q W p μ–

  7. Standard Model Theory With the interaction Lagrangian in hand, we can calculate the capture rate using S-matrix formalism: where the matrix element is This gives an expression relating the muon capture rate Λ to the induced form factors. Muon capture is a means of probing hadronic structure: a 1% measurement of Λs determines the induced pseudoscalar form factor gp to < 7% precision.

  8. Motivation gphas long been the least well-known of the weak nucleonic charged- current form factors. gV = 0.9755(5) values and q2-dependence are known from EM form factors via CVC. gM = 3.5821(25) value known from β–decay; q2-dep. is known from neutrino scattering. gA = 1.245(3) gP = ? (8.26, 8.7, 10.6, 12.2 …)

  9. Motivation No overlap between theory/RMC/OMC exp

  10. How Is MuCap Better? Improved Target: We use 10 bar, ultra-pure protium gas (impurities at 10–8 level, deuterium-depleted H2 to 1 ppm). This dramatically reduces molecular formation complications and related distortions in the lifetime histograms. High Statistics: In order to measure ΛS to 1% precision, we intend to measure both μ+ and μ– lifetimes to the level of 10 ppm, which requires recording 1010 decay events for each species. This is possible through our unique combination of detectors (especially our active target) and analysis capabilities.

  11. Experimental Setup – Facilities Location Paul Scherrer Institute (PSI), Switzerland Muon Source • PSI accelerator (ring cyclotron) generates 590 MeV proton beam (v ~ 0.8c) • protons crash into graphite target and produce pions • pions decay to muons Muon Beam Properties • Particles: μ+ or μ– • Momentum ~ 30-40 MeV/c • rate ~ 50 kHz

  12. Experimental Setup – Apparatus muSC (t = 0) muPC1 Muon Detectors muPC2 TPC μ beam • eDetectors cover 75% of 4π • μ,e detectors are decoupled to prevent cross-talk Electron Detectors ePC1 eSC (Hodoscope) ePC2

  13. Experimental Setup – TPC • The time projection chamber (TPC), is our active gas-filled target. It operates in proportional mode and records anode and cathode signals from entrance muons and decay electrons. • The TPC is the heart of the experiment: it allows us to identify good muon stops and perform vertex matching between a muon and its corresponding decay electron. The TPC can also be used for pileup and wall-stop protection, and to determine low levels of impurities in the H2 gas.

  14. 2003 Commissioning Run Assembly: March → August Data-Taking: September → mid-October. First “complete” setup since MuCap inception in 1997.

  15. 2003 Commissioning Run muSC (t = 0) muPC1 Partial setup ↓ Muon and electron track vector reconstruction not possible ↓ Vertex matching not possible (no local pileup protection) Muon Detectors muPC2 TPC (partial) μ beam Electron Detectors ePC1 eSC (Hodoscope) ePC2

  16. 2003 Commissioning Run In spite of numerous complications, we achieved some excellent first results: First combined assembly of muon detectors (including functional TPC), electron detectors, and high-speed DAQ.

  17. 2003 Commissioning Run We achieved gas impurity levels of 10–7, as determined from real-time software analysis of impurity events, and post-run chromatography analysis.

  18. 2003 Commissioning Run From September 25 → October 8 we estimate to have recorded ~ 109 good μ– TPC stops. I have spent 2004 analyzing this data, originally hoping to extract a 10% measurement of Λs.

  19. 2003 Commissioning Run 2003 data error spreads RMC gp cP-Theory proposed statistics systematics (D2 ) exp theory OMC Saclay lOP (ms-1)

  20. Upcoming 2004 Run This year we hope to fill in all of the missing pieces...

  21. 2004: Improvements new beampipe + muon detector assembly for accurate tracking and enhanced muon stopping fraction second electron wire chamber (ePC2) is operational for electron tracking

  22. 2004: Improvements New on-site gas cleaning, recirculation, and quality monitoring systems are ready

  23. Outlook 2004 Higher TPC voltage Faster, better DAQ Greater than 109 statistics Setup and testing Data-taking Analysis...

  24. Collaborating InstitutionsPetersburg Nuclear Physics Institute (PNPI), Gatchina, RussiaPaul Scherrer Institute (PSI), Villigen, SwitzerlandUniversity of California, Berkeley (UCB and LBNL), USAUniversity of Illinois, Urbana-Champaign (UIUC), USAUniversite Catholique de Louvain, BelgiumTU Munich, Garching, GermanyUniversity of Kentucky, USABoston University, USA The MuCap experiment is supported in part by the United States Department of Energy and the National Science Foundation. www.npl.uiuc.edu/exp/mucapture

More Related