H12-425_V2.0-ENU HCIP-Data Center Facility Deployment V2.0 Dumps

Passcert provides authentic H12-425_V2.0-ENU HCIP-Data Center Facility Deployment V2.0 Dumps which is the most reliable solution to quickly prepare for your exam and help you pass your exam easily.

Download Presentation

H12-425_V2.0-ENU HCIP-Data Center Facility Deployment V2.0 Dumps

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Free Huawei H12-425_V2.0-ENU Practice Exam Q&As HCIP-Data Center Facility Deployment V2.0 https://www.passcert.com/H12-425_V2.0-ENU.html

  2. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 1. When the UPS2000G battery status is NA, what could it be? A. The battery is not connected B. Battery Low Voltage C. The battery connection is normal D. The battery N line is not connected Answer: A

  3. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 2. What could be the cause of damage to the NETCOL5000-C insulation? A. The fan noise is too loud B. The drainage capacity of the equipment is significantly reduced C. Pipeline condensation D. The fan is blocked Answer: C

  4. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 3. U-position self-identification technology is used to ensure accurate placement of IT equipment. Which feature of NetEco is this? A. Capacity Management B. Energy Efficiency Management C. Asset Management Answer: A

  5. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 4. What is the maximum IT load supported by the FusionModule2000 integrated UPS? A. 50kW B. 125kW C. 150kW D. 75kW Answer: B

  6. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 5. Which type of compressor is used in new room-level air cooling? A. AC inverter compressor B. Digital scroll compressor C. Fixed frequency compressor D. DC inverter compressor Answer: B

  7. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 6. Which of the following resources can be managed by the capacity management function of the Huawei NetEco management system? (Multiple choice) A. Cabinet space B. Distribution Capacity C. Cooling capacity D. Room area Answer: ABC

  8. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 7.What are the alarm management functions supported by the ECC800? (Multiple choice) A. View historical alarms B. Filter alerts C. Alarm data export D. Alarm parameter setting Answer: ABCD

  9. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 8. What are the main components of the natural cooling source system? (Multiple choice) A. Direct ventilation and natural cooling B. Natural cooling by runner heat exchange C. Natural cooling on the water side D. Chilled water cooling scheme Answer: ABC

  10. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 9. What can users do through the ECC800WEB interface? (Multiple choice) A. Real-time monitoring of equipment status B. Query version information C. Export historical data D. Software Upgrade Answer: ABCD

  11. Free H12-425_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 10. The form of humidifier adopted by the row-level chilled water intelligent temperature control product NetCol5000-C032H is ( ). (Fill in the blank) A. Wet film Answer: A