110 likes | 249 Views
Precept en Conventional Control Panels. EN54 approval 2,4,8,16 & 32 zones Key-switch user control access Multi-language display options Semi-flush / fully-flush bezel options Removable chassis for installation 4 alarm circuits as standard on 4 zone panel upwards .
E N D
Precepten Conventional Control Panels • EN54 approval • 2,4,8,16 & 32 zones • Key-switch user control access • Multi-language display options • Semi-flush / fully-flush bezel options • Removable chassis for installation • 4 alarm circuits as standard on 4 zone panel upwards
Precepten Conventional Control Panels • Up to 5 fully functional repeaters connected via 2 core RS485 data cable • Remote panel inputs • Class change • Evacuate • Silence alarms • System reset
Precepten Conventional Control Panels • Remote panel outputs • Evacuate • Buzzer active • Disablement active • Configurable panel outputs • (See later slide)
Precepten Conventional Control Panels • 8-Way panel enhancement modules • (See Later Slide) • Comprehensive end user facilities • (See later slide) • Extensive DIL-switch options • (See later slide) • Disable buzzer for commissioning
Cabinet Options Surface Cabinets Cabinet colour reference is: RAL 7035 textured (Light Grey) All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint. Semi-Flush Cabinets The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall. It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet. Fully Flush Cabinet Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted. This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time-consuming).
Mechanical Assembly Multiple earth termination points located adjacent to cable entries. Mounting points for the motherboard chassis. Display and motherboard chassis are removable for ease of wall mounting. 24V battery set.
Panel Configuration Options • On-board panel options configurable by DIL switch, display or motherboard links as appropriate • Selected/all detection zones configurable as: - • Latching / non-latching • Short circuit to fire for older type detectors • Delay / non-delay • Standard / Intrinsically safe • Sounders Enable / disable fire protection output operation for non-latch zone operation • Alarm Sounder circuits configurable as standard or zonal operation • Relays configurable as either Powered fault monitored or volt free • Inhibit or enable earth fault monitoring • Enable / disable latching fault indications • Alarms to operate on any fire & evacuate or on evacuate only • One-man test to be silent or 2 second sounder operation
Panel Configuration Options • One man sounder test • Delay configuration options • Any zone to be configured as delay zone • Single or 2-stage delay • 1-9 minute delay if single stage • 1 minute + 1-9 minute delay if 2-stage • Fire routing, fire protection, sounders – can be any combination • Inhibit silence / reset for 3 minutes after fire operation • Operate sounders on “Evacuate” only option • “Reset” only possible after “Silence” option • Disable panel buzzer
8-Way Panel Enhancement Modules • 4 options for 8-way enhancement modules • 8 open collector outputs + PSU fault input • 8 C/O relay contacts + PSU fault input • 8 monitored sounder outputs + PSU fault input • 8 fault monitored, powered fire protection outputs + PSU fault input • Matching cabinets to house enhancement boards and power supplies • Timer clock counter • Set as day/night and alarm counter • Or fire alarm clock display
Extensive User Facilities • Full disablement facilities • Individual zones • Fire routing • Fire protection • Fault routing • Sounder circuits • One man zone test • One man sounder test • Enable / disable delay mode • Override delay mode • Extend delay (from 1st to 2nd stage)