Stand-alone controller with sensors that optimize operation of 9 heating areas on the bridge. Ensures safety with overheating protection and precise temperature management.
E N D
Bridge Heating Controller • Located on the right end side of the bridge. • Stand alone controller that controls 9 heating elements. • All 9 heating elements are divided into 6 heating areas, which are controlled separately. • Supplied with 35VAC for heating elements operation. • Supplied with 12VDC for the controller operation. • Communicates with the computer via RS422 port on the controller. • 6 sensors read the temperature from the 6 heating areas which are spread on the bridge. Confidential
Bridge Heating Controller (Cont.) • Located on the right end side of the bridge. • The heating sensors generates 10mV for every 1ºC of temperature. • There are 3 thermo switches for bridge overheat protection. • If the bridge temperature exceeds 45ºC, the power to the heating elements is cut off. Confidential
Bridge Heating Controller (Cont.) Confidential
Bridge Heating Controller (Cont.) Confidential
1 3 5 2 4 6 Bridge Heating Controller (Cont.) • Bridge heating areas are arranged in inside the bridge in the following order: Confidential