1 / 8

Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma)

Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products. Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma).

cdevoe
Download Presentation

Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) Altogen Biosystems offers the NCI-H23Transfection Reagent among a host of 100+ cell line specific In Vitro Transfection Kits. The NCI-H23 Transfection Reagent is a two-component formulation that enhances lipid-mediated transfection, and it has been developed to provide high transfection efficiency with the NCI-H23 cell line. This cell line is a good host for medical research related to lung cancer. When cultured in vitro, NCI-H23 cells are a monolayer and adhere to the surface of the culture flask. Other applications include drug discovery, gene expression studies, molecular and cell biology research applications. Purchase NCI-H23 Transfection Kit at www.Altogen.com Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  2. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) NCI-H23 Cell Line Description and Applications The NCI-H23 cell line originates from the lung cancer tissue derived from a 51-year old male who was suffering from adenocarcinoma and had not received any therapy prior. The cell line displays epithelial morphology and carries the K-ras 12 mutation as well as a p53 mutation. The NCI-H23 cell line has a population doubling time of approximately 38 hours and has a reported colony forming efficiency of 9.7% in soft agarose. This cell line is an excellent resource for biomedical research related to lung cancer. High Density NCI-H23 cells atcc.org Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  3. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) NCI-H23 Transfection Protocol 1. Plate 10,000 - 15,000 NCI-H23 cells per well in 0.5 ml of complete growth medium 12–24 hours prior to transfection 2. Wash with 1xPBS and add 0.5 ml of fresh growth medium 3. Prepare transfection complexes by mixing 40 µl of serum-free medium, 5.5 µl of transfection reagent, and • 750 ng DNA (or mRNA), or • 30 nM - 50 nM of siRNA (or microRNA) *Referred to a final volume including growth medium 4. Incubate transfection complexes at RT for 15 - 30 minutes 5. Optional: Add 2 µl of Complex Condenser. This reagent reduces the size of transfection complex, therefore increasing transfection efficiency; however, it may increase cell toxicity 6. Add prepared transfection complexes to 0.5 ml of complete growth medium with NCI-H23 cells (from step 2) 7. Incubate cells at 37ºC in a humidified CO2 incubator 8. Assay for phenotype or target gene expression 48 - 72 hours after transfection Optional: Transfection efficiency can be increased by addition of Transfection Enhancer reagent. Add 2 µl of Transfection Enhancer reagent 12-24 hours after transfection If the viability of NCI-H23 cells being transfected is affected at 16 - 24 hours post-transfection, the level of cytotoxicity can be decreased by changing the growth medium and eliminating redundant exposure of cells to transfectant Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  4. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) General Lipoplex-mediated Transfection Mechanism of Action Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  5. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) NCI-H23 Transfection Kit Product Details • Two-component formulation enhances lipid-mediated transfection efficiency • Optimized for intracellular delivery of plasmid DNA, siRNA, microRNA, and mRNA • High transfection efficiency of both siRNA and plasmid DNA without compromising cell viability • Achieve robust siRNA uptake for dependable gene silencing • Effective transfection under conditions of up to 40% serum • Transfection kit includes Transfection Enhancer reagent • Gentle enough to be used for single cell analysis • Developed and manufactured by Altogen Biosystems (www.Altogen.com) Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  6. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) Data Figure 1. siRNAs targeting Lamin A/C mRNA or non-silencing control siRNA were transfected into NCI-H23 cells following the recommended protocol. At 48 hours post-transfection the cells were analyzed by qRT-PCR for Lamin A/C gene expression levels. 18S rRNA levels were used to normalize the Lamin A/C data. Values are normalized to untreated sample. Data are means ± SD (n=4).

  7. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) Data Figure 2. Protein expression of Lamin A in NCI-H23 cells. DNA plasmid expressing Lamin A or siRNA targeting Lamin A were transfected into NCI-H23 cells following Altogen Biosystems transfection protocol. At 72 hours post-transfection the cells were analyzed by Western Blot for protein expression levels (normalized by total protein, 10 µg of total protein loaded per each well). Untreated cells used as a negative control.

  8. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > NCI-H23 Transfection Reagent (Lung Adenocarcinoma) NCI-H23 Transfection Kit Benefits • Pre-optimized transfection protocol for NCI-H23 cell line • Compatible with DNA, small RNA (siRNA, shRNA, miRNA), mRNA, and small protein complexing • Free of serum and protein of animal origin • Compatible with standard and reverse transfection methods (both protocols provided in the kit manual) • Easy to use NCI-H23 transfection protocol ensures great performance with expedited experimental timeline • Equally efficient for single or multiple transfections • Can be used for transient transfection and development of stable NCI-H23 cell lines • Bio-degradable after endocytosis • Used for preclinical research worldwide Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

More Related