1 / 15

CONTENTS

CONTENTS. Description of ITKnife2  Specifications  Improvements  Features & Benefits  Warning  Competitors  Summary. DESCRIPTION. ITKnife2  KD-611L  Single Use ESD Knife. SPECIFICATIONS. Naming Rule K D – 6 1 1 L (1) (2)(3) (4). (1) KD = Product Type - Diathermy Knife

cera
Download Presentation

CONTENTS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CONTENTS • Description of ITKnife2 SpecificationsImprovements Features & Benefits WarningCompetitorsSummary

  2. DESCRIPTION • ITKnife2 KD-611LSingle Use ESD Knife

  3. SPECIFICATIONS • Naming RuleK D – 6 1 1 L(1) (2)(3) (4) (1) KD = Product Type - Diathermy Knife (2) 6 = Device Feature - Single Use Electrosurgical Knife (3) 1 = Distal End Feature – Electrosurgical Tipped Knife (4) L = Working length - (L=1650mm)

  4. SPECIFICATIONS • Colour Change KD-600 Series ITKnife2 (KD-611L) Easily differentiate from other ESD devices

  5. SPECIFICATIONS

  6. IMPROVEMENTS • Additional Electrode at the bottom of the insulated tip

  7. IMPROVEMENTS ①Approach ①Approach ② Incision ③ Incision ② Pressing knife Pressing knife is necessary Pressing knife isnotnecessary ⇒Incision is difficult if condition does not allow pressing ⇒Incision is possible even if condition does not allow pressing

  8. IMPROVEMENTS Improved points ② – Lateral incision ① Area where ITknife can incise easily Direction of incision Lesion ② Area where difficult for ITknife to incise Direction of incision ITknife2 facilitates incision in ② areas Direction of scope approach

  9. Electrode FEATURES & BENFEITS • Additional Electrode - wider dissectible area, wider range movement Facilitates Haemostasis – without pressing – less bleeding, better visual

  10. WARNING • Inform users of risk of ESD procedures and device  Higher performance cut than ITKnifeShort incision range Upper GI only

  11. WARNING Warning statement in instruction manual & on packaging

  12. COMPETITORS • All ESD knives copied from Olympus!

  13. COMPETITORS

  14. SUMMARY • Use ESD interest as ‘door opener’ Additional Electrode Facilitates Haemostasis