1 / 6

Empower Success D-PVM-DS-23 PowerMax & VMAX Family Solutions Design 2023 Mastery

The D-PVM-DS-23 exam with our expert-led resources. Master Dell Technologies PowerMax and VMAX Family Solutions Design 2023 with comprehensive study materials, practice tests, and expert guidance. Our proven strategies will help you navigate through the exam objectives and ensure your readiness to achieve certification. Join the ranks of certified professionals and stand out in the competitive IT landscape. Start your journey to success today with our trusted exam preparation resources!<br>https://www.certsgrade.com/pdf/D-PVM-DS-23/

Download Presentation

Empower Success D-PVM-DS-23 PowerMax & VMAX Family Solutions Design 2023 Mastery

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dell EMC D-PVM-DS-23 Dell Technologies PowerMax and VMAX Family Solutions Design 2023 Questions And Answers PDF Format: For More Information – Visit link below: https://www.certsgrade.com/ Version = Version = Product Visit us athttps://www.certsgrade.com/pdf/d-pvm-ds-23/

  2. Latest Version: 6.0 Question: 1 A storage architect is designing a PowerMax solution. The architect must customize the maximum SRDF/A cache usage. Which system view can the architect use to meet this requirement? Response: A.Performance B.System Properties C.Data Protection D.System Settings Answer: D Question: 2 A customer has Open Systems, Mainframe, and IBM i systems in the data center. Which arrays can be used to consolidate these independent systems into a single array? Response: A.VMAX All Flash 950 and PowerMax 2000 B.PowerMax 8000 and VMAX All Flash 950 C.PowerMax 2000 and PowerMax 8000 D.VMAX All Flash 250 and VMAX All Flash 950 Answer: B Question: 3 In what format can loaded and mapped BCSD performance data be exported? Response: A.DOC B.XML C.CSV D.PFD Answer: C Visit us athttps://www.certsgrade.com/pdf/d-pvm-ds-23/

  3. Question: 4 What types of files are supported for import into Sizer? Response: A.TTP, DCF, CSV, and configuration files B.TTP, CSV, and configuration files only C.BTP, DCF, CSV, and configuration files D.BTP, DCF, and configuration files only Answer: C Question: 5 When adding device pairs to an SRDF/Metro configuration using the -exempt option, what prevents a device pair from being added? Response: A.R2 device is larger than the R1 device B.Source group and device pair are in SRDF/S mode C.R1 device is the source of a TimeFinder data copy D.Source group and device pair are in SRDF/Adaptive Copy mode Answer: A Question: 6 Open Replicator is being used to copy data from a VNX to a PowerMax. During the migration, users experience latency when accessing the storage from the VNX. What can be done to address the issue? Response: A.Reduce Pace and Ceiling Value B.Set Pace to 0 and Ceiling to 50% C.Reduce Ceiling Value D.Nothing, because copying has started Answer: C Question: 7 Visit us athttps://www.certsgrade.com/pdf/d-pvm-ds-23/

  4. What is the default HTTPS port assignment for communication of VSI/IAPI requests sent to REST API of Unisphere for PowerMax? Response: A.5441 B.5443 C.8441 D.8443 Answer: D Question: 8 Which role is required to rename a service level in Unisphere for PowerMax? Response: A.Administrator B.Storage Administrator C.Security Administrator D.VM Administrator Answer: B Question: 9 While designing a SnapVX solution for a volume that is mapped to a Unix server, a storage architect decides to take three snapshots per day and retain them for six weeks. The Unix team would like to take a few on-demand snapshots before and during an upgrade activity. How many snapshots can be taken without disrupting the daily snapshots? Response: A.130 B.256 C.898 D.1024 Answer: A Question: 10 By what percentage is SRDF throughput improved by SiRT? Response: Visit us athttps://www.certsgrade.com/pdf/d-pvm-ds-23/

  5. A.10% B.20% C.30% D.40% Answer: B Visit us athttps://www.certsgrade.com/pdf/d-pvm-ds-23/

  6. For More Information – Visit link below: https://www.certsgrade.com/ PRODUCT FEATURES 100% Money Back Guarantee 90 Days Free updates Special Discounts on Bulk Orders Guaranteed Success 50,000 Satisfied Customers 100% Secure Shopping Privacy Policy Refund Policy 16 USD Discount Coupon Code: NB4XKTMZ Visit us athttps://www.certsgrade.com/pdf/d-pvm-ds-23/ Powered by TCPDF (www.tcpdf.org)

More Related