An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thermal controlGSE at KSC

  2. TCS – GSE scope • AMS at KSC will be in flight configuration (radiators) • The TCS GSE shall allow the correct detector operation during the ground integration. • The only GSE to be used at KSC will be electrically powered fans of two kind, to provide forced convection cooling. • Several fans will blow air towards specific AMS components in order to keep their temperature in the operative range.

  3. Elements to be cooled • Air cooling • Electronic crates and XPDs • Main radiators (RAM and WAKE) mounted • Cryocoolers (with LHP integrated, hence sunk to the zenith radiators) • PDS (mounted on WAKE radiator) • CAB (with LHP integrated, hence sunk to the wake radiator) • All other subdetectors don’t need forced convection cooling, free convection being sufficient.

  4. Type A Fans • Quantity 12 • Diameter > 0.45 m • Flow Rate 4100 m3/h • Unit power (reference value) 135 W • Voltage 110 V • AC supply Frequency 60 Hz

  5. Four fans will blow to the electronic units mounted on the Ram radiator, having their axis parallel to the radiator • Four fans will blow to the electronic units mounted on the Wake radiator , having their axis parallel to the radiator • Four fans will blow the Zenith Radiator, having their axis parallel to the 4 zenith radiator quadrants

  6. Fans on zenith radiators Wake Ram Main Radiator Wake Main Radiator Ram

  7. Fans on RAM radiator Wake Ram Main Radiator Wake Main Radiator Ram

  8. Fans on WAKE radiator Wake Ram Main Radiator Wake Main Radiator Ram

  9. Type B Fans • Quantity 3 • Diameter >0.18 m • Flow Rate 740 m3/h • Unit power (reference value) 50 W • Voltage 110 V • AC supply Frequency 60 Hz

  10. Type B fans usage • One fan is dedicated to the PDS, and it shall work at the same time of the Wake radiator fans. • The other two fans shall blow air to the CAB on two of its faces (wake and starboard).

  11. Type B fans location Wake Ram Main Radiator Wake Main Radiator Ram

  12. Quality stamp on COTS • All fans will be commercial off the shelf (COTS) and have the European “CE” quality symbol on it. • The supplier of the fans is TBD.