SITOP power flexiThe power pack handles it all - from 3 to 52V SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power flexiSpecial features • Output voltage adjustable from 3 to 52 V • By using a potentiometer or analog input signal (0 to 2.5 V) • Can even be adjusted dynamically during operation • Max. output current adjustable from 2 to 10 A • By using a potentiometer or analog input signal (0 to 2.5 V) • Current monitoring • Output current depending on the analog signal (0 to 2.5 V) • Red LED indicates when the set current limit is reached • Additional functions • Automatic power limitation to 120 W • Sense line for precise voltage to power load • Power-ok signal provided as a relay contact • Power-fail signal SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power flexiApplication areas and customer advantages • One device for different applications • Lower logistics costs • Easier to configure • Easier to service • Standard device instead of special power pack • For “non-standard” voltages between 3 and 52 Volt • For applications, with a need for a direct current, which can be changed dynamically • lab applications, testing systems, control of DC motors etc. • For load control with integrated current monitoring • As battery charger due to adjustable current limitation • All the advantages of a standard SITOP power device (e.g., industrial capability, ready to use, high quality, compliance with all pertinent international standards,) • Comparable price to standard Dc 24V/ 100 watt unit SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power flexiOutput characteristic 60 50 SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i 40 30 Volt 1 ) 20 2 ) 10 0 0 2 4 6 8 10 12 Ampere 1) Range of adjustment for output voltage2) Range of adjustment for current limiting
SITOP power dual 15VMounted quickly, even at ±15 V! SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power dual 15VSpecial features and customer advantages • Industrial-capacity, compact device for the switching cabinet • Wide-range input (93 to 264 V AC) for worldwide use • Two floating outputs (15 V DC/3.5 A) • Can be used in parallel for 15 V/ 7 A (single output) • In series for ±15 V/ 3.5 A (dual output) • Simple compensation of power losses • Outputs adjustable from 14.5 to 17 V with potentiometer in front • Extremely easy to handle • Fast mounting on standard DIN rail • Easy wiring SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power dual 15VApplication areas • General mechanical engineering • Powering of electronics • Powering of operation amplifiers • Laser processing machines • Powering of deflection mirrors of laser heads(e.g., with laser inscribers) • Measuring technology • Powering of measuring converters SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power 0.5 - Power out of 22.5 mmIdeal for low-voltage switchgear SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power 0.5Special features • AC version: 24 V/ 0.5 A • DC version: 24 V/ 0.375 A • Wide range input • AC version: Urated= 120 - 230V AC (87 ... 264V AC) • DC version: Urated= 48 - 220V DC (30 ... 264V DC, 30 ... 187V AC) • Width: 22.5 mm • Weight: 0.11 kg (AC) / 0.14 kg (DC) • Temperature range: -20° to +70° C SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power 0.5Customer benefits • Space savings • Due to narrow width and minimum space requirement • Optimal for use in switching cabinet • Cost savings • Due to use of 24 V standard contacter and relay types for "odd" voltages • Due to reduced number of models because of wide-range input • Time savings due to availability from warehouse • Worldwide use • Certifications in according with UL and cUL SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power 2-phase 20AFor high network voltages SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power 2-phase 20A Special features and application areas • 24VDC /20 A DC for 3-phase networks in 480 and 575 VAC • 2-phase power supply • No need for line protection of third phase • Single phasing doesn‘t require additional protection devicesas recommended with 3w-phase power supplies • Wide- input voltage range from 420-682 VAC for ... • 575VAC 3-phase networks in the USA and Canada • Highest protection against voltage fluctuations in case of unstable network conditions • Adjustable output voltage from 22.8 to 28.8 V • Devices can be switched in parallel • Provides agency approvals for the North American market • UL, cUL, CSA SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
Power supplies in SIMATIC design • Optimal for SIMATIC S7-200 • AC 120/230 V, 24 V/ 3.5A • RFI specification class B • Parallel connection possible • Slim like the SIMATIC ET200B • AC 120/230 V, 24 V/ 5 A and 10 A • Optimal for use with distributed I/O device • Minimum width requirements when used with a mounting bracket (2.5 inch width even for 10 amp unit)) SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
Power supply with degree of protection IP65 Optimal for the SIMATIC ET 200X • Single phase 120/230 VAC, 24 VDC/10A • Design adapted to SIMATIC ET200X • 24 VDC via back plane bus for electronics/ encoders and/or load • 24 VDC via screw-type terminals for loads • Choice after short circuit: • Automatic restart • Switch off • For use under roughest conditions from -25 to +55°C • Can be installed in any position SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
SITOP power with direct current and universal connection • Direct current input (DC/DC 2A) • For 48/60/110 V battery networks via DC input 38 to 121 V • Universal connection (2.5/4/10 A) • For 120 V and 230 V power networks without switching thanks to wide-range input range from 93 to 264 V AC • For 220 VAC - battery systems. DC operation within 110 to 350 V possible • Parallel connection for redundancy and power increase • Design adapted to SIMATIC AG 95/100 (2.5/ 4A) SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i
Power supplies for AS-interface • 30 VDC /2.4 A in class of protection IP 65 • Input voltage from 20.4 to 28.VDC • Only 57 mm mounting depth • No mounting restrictions • Ambient temperaturefrom -25° to +55°C • 30 V/7 A with wide input voltage range from • 93 to 264 VAC or 110 to 350 VDC • Can be snapped on standard DIN rail or specific S7-300 rail • Data buffering according to the AS-i specification • Also suitable for public low voltage networks SITOP power flexi SITOP power dual SITOP power 0.5 2-phase 20A In SIMATIC design DC/UC- Input For AS-i