Dialysis Machine HDM-1000A

Medzer Dialysis Machine aids kidney function for impaired patients, offering sodium and UF profiling, KT/V efficacy calculation, hemoperfusion for water conservation, isolated dialysis, adjustable blood pump speeds from 15 to 460 ml/min, and various disinfection modes.

cherylross
Download Presentation

Dialysis Machine HDM-1000A

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dialysis Machine HDM- 1000A www.medzer.com | info@medzer.com

  2. Specifications : Venous pressure -700 ~+800 mmHg, Accuracy ± 10 mmHg Arterial pressure +800mmHg, Accuracy±10mmHg Trans membrane pressure -700 mmHg ~ +800 mmHg, Accuracy±10 mmHg Blood pump 15 ml/min ~ 340 ml/min (D 6 mm) 20 ml/min ~ 460 ml/min (D 8mm) Heparin pump 0 ml/h ~ 10 ml/h (±5 %) Precision 0.1 ml/h Blood flow range 0 ml/min ~ 700 ml/min Dialysate flow range 0 ml/min ~ ( 300/500/800 ) ml/min (Adjustable) Substitution Fluid Flow 0 ~ 25 l/h Dialysate temperature 30 ℃ ~ 41 ℃, Accuracy ± 0.1℃ Conductivity 10 ms/cm ~ 20 ms/cm Accuracy ± 0.1 ms/cm Air detector Detecting ≥ 0.02 mL/single bubble

  3. Flow scope UF flow scope: 0 ~ 1800 ml/h (±30 ml/h ) ISO UF flow scope: 0 ~ 2000 ml/h (±30 ml/h) Blood Leak detector Detecting blood leak ≥ 0.35 ml/min (HCT 32%) Hot rinse ≥85℃ Disinfection Decalcification: Rinse, citric acid Thermal disinfection:Hot water or citric acid Chemical disinfection: sodium hypochlorite or peracetic acid Water supply Pressure range: 0 bar ~ 8 bar Temperature range: 0 ℃ ~ 35 ℃ Connected load ≤ 2000 VA Power supply AC 220 V, 50 Hz ~ 60 Hz Dimension 850 × 840 × 1660 mm Weight 140 kgs Features :

  4. Sodium and UF profiling Program for sequential therapy and dialysis with variational sodium KT/V calculation evaluates the sufficiency of dialysis Hemoperfusion mode reduces water consumption Provision for isolated dialysis Back-up power supply for 30 min after electricity off Medzer Inc Brandy Wine, 1000 N West St, Wilmington, DE 19801, United States Email: info@medzer.com | Website: www.medzer.com