1 / 17

The Support Structures for the Scibar and EC

The Support Structures for the Scibar and EC. April 13, 2006 Edward Chi Fermi/PPD/MD/ME. Frame for the Scibar & EC Supt. structure. Main frame w/Scibar module supt brackets. A near view of the Scibar support bracket: Each bracket housing 4 modules, has +/- 0.5” y dir. adjustment,

Download Presentation

The Support Structures for the Scibar and EC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Support Structures for the Scibar and EC April 13, 2006 Edward Chi Fermi/PPD/MD/ME

  2. Frame for the Scibar & EC Supt. structure

  3. Main frame w/Scibar module supt brackets

  4. A near view of the Scibar support bracket: Each bracket housing 4 modules, has +/- 0.5” y dir. adjustment, Infinite z dir. adjustment for each bracket.

  5. The Frame with the 32 horizontal EC modules, adjustable in x, y & z dir.

  6. The installation of the vertical 32 EC modules with x, y & z adjustabilities.

  7. A view from the downstream of the support frame (back view)

  8. Install the 1st Scibar modul layer with the Lifting fixture (from upstream of the frame)

  9. View from the back of the 1st installed scibar module with the lifting fixture

  10. View with all 64 scibar modules (only shown 3 layers for computer space sake)

  11. The view of PMT frame and Scibar and EC supt. frame.

  12. Near view of the PMT frame with x, y and z adjustabilities

  13. Removable module type top dark room and service floor: 75 lbs/ft sq load rating, 2’ x 2’ x 1” module (ply wood), overall height in y dir: From the bottom surface of the base plate to the top surface of fl. Must be within: 158.0”

  14. View after taking off one module of top dark room floor

  15. If one is not enough, take off 2 modules, or 3, 4….

  16. The total distance between the top of the Scibar module to the bottom surface of the dark room floor is 60cm. This is restricted by the overall height of the CDF door.