130 likes | 284 Views
MPRN Creation Workgroup. Tuesday 27 th March 2012. Agenda. Introduction Meeting scope MPRN creation process overviews High level overview ‘FOM’ creation process Triggers for MPRN Creation Review scenario’s Issues/exposure with current process
E N D
MPRN CreationWorkgroup Tuesday 27th March 2012
Agenda • Introduction • Meeting scope • MPRN creation process overviews • High level overview • ‘FOM’ creation process • Triggers for MPRN Creation • Review scenario’s • Issues/exposure with current process • Review links to Shipperless & Unregistered sites • A.O.B.
Meeting scope • Stand alone ‘focus’ workgroup • Strictly distinct from Uniform Network Code MOD’s • Consensus to be met across industry participants • Aspire to formulate a ‘Best Practise’ document
MPRN Creation overview Shipper Shipper views response on ConQuest Shipper receives QMR, QMJ files throughout day via IX QCL after 8pm Shipper Identifies a site without an existing MPRN Shipper Submits MNC via ConQuest UIP UIP receives QMR, QMJ, QCL files the following AM via email UIP submits FOM via ConQuest (inc. allocated MPRN) UIP has a new connection & requires new MPRN Requests rec’d & validated/DUP checks undertaken Xoserve create/reject MPRN as necessary Response updated to Conquest & visible to requestor Response files .QMR .QMJ .QCL are sent APPENDIX UIP: Utility Infrastructure Provider (Connection Company) FOM: ConQuest Contact Code for MPRN requests from UIP MNC: ConQuest Contact Code for MPRN requests from Shipper ConQuest: Xoserve Query Management System
SOS95% of requests to be resolved within D+1 CustomerShipperDeveloper End Consumer MPRN Creation process - FOM Xoserve allocate batches of MPRN’s to requesting UIP’s Xoserve notify UIP MPRN set up Customer requests service quote xoserve validate & create MPRN on UK Link UIP produces quote UIP notifies customer & Xoserve of allocated MPRN Customer accepts quote UIP confirms job acceptance & allocates MPRN
Triggers for MPRN Creation a) Service laid at same point on the main (Alteration of service, Service replacement & Capacity increase) b) Old service disconnected and new service fitted at a different location in the gas main
Triggers for MPRN Creation c) Old service disconnected and new service fitted at different main d) Additional service fitted at different points in same gas main
Triggers for MPRN Creation e) House converted to flats old service removed and additional services fitted at different points in the same gas main f) House converted to flats and existing service changed to flat 1 and additional services fitted at different points in the same gas main
Triggers for MPRN Creation g) New service laid at any point on the main (New Development) also Plot address
Issues with current process • Meters fitted; Shipper/Supplier not informed • Cancelation requests: Suspected low volumes;
Links to S&U sites • At the point of MPRN request; • Created prematurely • Created erroneously & not cancelled • Circa 105k MPRN’s created in 2011 • ‘FOM’ = 85k & ‘MNC’ =20k • Inflation of Shipperless & Unregistered population
AOB • Any other business? • Thanks for your attendance… • … your contribution & support